Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | Switch Mode | Turn your dimmer into an On/Off switch with switch mode | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | Disable normal operation | |||
1 | 1 | Enable switch mode | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 1 | Alternate Exclusion | Never accidentally remove a device during with alternate exclusion | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | Normal operation, press any button on the device | |||
1 | 1 | Press two times ON button and two times OFF button, LED will flash 5 times if exclusion is successful | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | LED Indication Configuration | Adjust the LED status to default, invert, always OFF or always ON | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | Device is ON, LED is OFF; device is OFF, LED is ON | |||
1 | 1 | Device is ON, LED is ON; device is OFF, LED is OFF | |||
2 | 2 | LED always OFF | |||
3 | 3 | LED always ON | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
30 | 1 | Minimum Dim Threshold | Set the minimum dimmer threshold | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 99 | No | No | Yes |
From |
To |
Description |
|||
1 | 99 | Set the minimum dimmer threshold when manually or remotely controlled | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
31 | 1 | Maximum Brightness Threshold | Set the brightness threshold | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
99 | 0 | 99 | No | No | Yes |
From |
To |
Description |
|||
99 | 1 | Set the maximum brightness threshold when manually or remotely controlled | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
32 | 1 | Default Brightness Level | Set the default brightness level that the dimmer will turn on when being controlled manually | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 99 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | Deafult | |||
1 | 99 | Ex. 1= 1% and 99 = 99% | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Dim up/down rate | Adjust the speed at which the ramps to a specific value other than 0 and FF | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | Yes |
From |
To |
Description |
|||
0 | 0 | Dim up/down the light to the specified level quickly by command except value 0 and FF | |||
1 | 1 | Dim up/down the light to the specified level slowly by command except value 0 and ff | |||