Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 2 | Heartbeat Rate | If the Notification System Heartbeat is on, a Notification Report System Heartbeat is sent periodically every 60 minutes (default value). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 1 | 1440 | No | No | No |
From |
To |
Description |
|||
1 | 1440 | Heartbeat rate [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 2 | Send Interval Humidity | If the humidity value does not change, the Multilevel Sensor Report with the actual humidity is sent after the Send Interval Humidity. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 120 | No | No | No |
From |
To |
Description |
|||
1 | 120 | Send interval humidity [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 2 | Minimum Delta Humidity Send | Whenever the measured humidity has changed by the Minimum Delta Humidity Send value since the last value sent, the actual humidity is sent by a Multilevel Sensor Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 10 | 1000 | No | No | No |
From |
To |
Description |
|||
10 | 1000 | Minimum delta humidity [0.1 %] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 2 | Main Voltage | The Main Voltage is used - together with the Phase Shift parameter and the messured current - to calculate the actual power of the output and the cumulated energy. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 80 | 280 | No | No | No |
From |
To |
Description |
|||
80 | 280 | Main voltage [V] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 2 | Phase Shift - Cosines (Phi) | The Phase Shift is used - together with the Main Voltage parameter and the messured current - to calculate the actual power of the output and the cumulated energy. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
100 | 0 | 100 | No | No | No |
From |
To |
Description |
|||
0 | 100 | Phase shift [0.01%] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 2 | Send Interval Power | If the power value of the output does not change, the Meter Report for the actual power is sent after the Send Interval Power. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 120 | No | No | No |
From |
To |
Description |
|||
1 | 120 | Send interval power [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 2 | Minimum Delta Power Send | Whenever the calculated power has changed by the Minimum Delta Power Send value since the last value sent, the actual power is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 100 | No | No | No |
From |
To |
Description |
|||
1 | 100 | Minimum delta power [%] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 2 | Minimum delta energy send | Whenever the cumulated energy has changed by the Minimum Delta Energy send value since the last value sent, the cumulated energy is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2000 | 1 | 50000 | No | No | No |
From |
To |
Description |
|||
1 | 50000 | Minimum delta energy [0.001 kWh] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 2 | Send Interval Temperature | If the temperature value does not change, the Multilevel Sensor Report with the actual temperature is sent after the Send Interval Temperature | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 120 | No | No | No |
From |
To |
Description |
|||
1 | 120 | Send interval energy [min] | |||
1 | 120 | Send interval temperature [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 2 | Minimum Delta Temperature Send | Whenever the measured temperature has changed by the Minimum Delta Temperature Send value since the last value sent, the actual temperature is sent by Multilevel Sensor Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 100 | No | No | No |
From |
To |
Description |
|||
1 | 100 | Minimum delta temperature [0.1 K] | |||