There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Mini Dimmer (ZMNHHD1)

Z-Wave Certification Number: ZC10-19056504


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 In-wall Switch Type for Load to control I1 0
(Default)
push-button (momentary)
  1 on/off toggle switch

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Turn Load 1 Off Automatically with Timer 0
(Default)
Auto OFF Disabled
  1 to 32536 1 - 32536 seconds - Auto OFF timer enabled for a given amount of seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Turn Load 1 On Automatically with Timer 0
(Default)
Auto ON Disabled
  1 to 32536 1 - 32536 seconds - Auto ON timer enabled for a given amount of seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Enable/Disable the Double click function 0
(Default)
double click disabled
  1 double click enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Restore on/off status for load after power failure 0
(Default)
Device saves last on/off status and restores it after a power failure.
  1 Device does not save on/off status and does not restore it after a power failure, it remains off.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Watt Power Consumption Reporting Threshold for Load 0 Power consumption reporting disabled
  1 to 100
(Default)
1% - 100% Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Watt Power Consumption Reporting Time Threshold for Load 0
(Default)
Power consumption reporting on time interval disabled
  30 to 32767 30 - 32767seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Working mode 0
(Default)
Dimmer mode
  1 Switch mode (works only in 3 way wiring-connection with neutral line)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Minimum dimming value 0
(Default)
0% (minimum dimming value)
  0 to 98
(Default)
0% - 98%, step is 1%. Minimum dimming value is set by entering a value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 1 Maximum dimming value 99
(Default)
99% (Maximum dimming value)
  1 to 99
(Default)
1% - 99%, step is 1%. Maximum dimming value is set by entering a value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 1 Dimming time when key pressed (soft on/off) 1
(Default)
1 second
  1 to 127
(Default)
1 seconds- 127 seconds, step is 1 second

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Dimming time when key hold 1 to 127
(Default)
1 second – 127 seconds
  128 to 253 1 minute – 126 minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

67 1 Ignore start level 0
(Default)
use the start level value
  1 ignore the start level value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

68 1 Dimming duration 0
(Default)
dimming duration according to parameter 66
  1 to 127 from 1 to 127 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

70 2 Overload safety switch 1 to 200
(Default)
1W - 200W
  0 function not active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

71 1 Calibration trigger 1 calibration done after power cycle regardless of inclusion status
  2 force calibration. Calibration will start immediately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

72 1 Calibration status (read only) 1 calibration was successful
  2
(Default)
calibration failed

Parameter Number

Parameter Size

Parameter Name

Parameter Values

73 1 Alarm/Notification events 1 turn OFF
  2 turn ON
  3 start blinking (output turns 1s ON, and 1s OFF)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

74 1 Alarm/Notification time interval (dependant on parameter 73) 1 to 125
(Default)
1-125 minutes