There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Wall Dimmer (FGWDEU-111)

Z-Wave Certification Number: ZC10-19056515


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Remember device state 0 remains switched off after restoring power
  1
(Default)
restores remembered state after restoring power

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 LED frame – power limit 100 to 5000
(Default)
(10.0-500.0W, step 0.1W) – power threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 LED frame – colour when ON 0 LED disabled
  1
(Default)
White
  2 Red
  3 Green
  4 Blue
  5 Yellow
  6 Cyan
  7 Magenta
  8 colour changes smoothly depending on measured power
  9 colour changes in steps depending on measured power

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 LED frame – colour when OFF 0
(Default)
LED disabled
  1 White
  2 Red
  3 Green
  4 Blue
  5 Yellow
  6 Cyan
  7 Magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 LED frame – brightness 0 LED disabled
  1 to 100
(Default)
(1-100% brightness)
  101 brightness directly proportional to set level
  102 brightness inversely proportional to set level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

150 1 Minimum brightness level 1 to 98
(Default)
(1-98%, 1% step) – level of brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

151 1 Maximum brightness level 2 to 99
(Default)
(2-99%, 1% step) – level of brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

152 1 Incandescence level of dimmable compact fluorescent lamps 1 to 99
(Default)
(1-98%, 1% step) – level of brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

153 2 Incandescence time of dimmable compact fluorescent lamps 0 to 255
(Default)
(0-25.5s, 0.1s step) – incandescence time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

154 1 Automatic control – dimming step size 1 to 99
(Default)
(1-99%, 1% step) – dimming step

Parameter Number

Parameter Size

Parameter Name

Parameter Values

155 2 Automatic control – time of dimming step 0 to 255
(Default)
This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic control.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

156 1 Manual control – dimming step size 1
(Default)
[MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action
  1 to 99
(Default)
(1-99%, 1% step) – dimming step

Parameter Number

Parameter Size

Parameter Name

Parameter Values

157 2 Manual control – time of dimming step 0 to 255
(Default)
(0-2.55s, 10ms step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

158 2 Auto-off functionality 0
(Default)
auto-off disabled
  1 to 32767 (1s-9.1h, 1s step) – auto-off time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

159 1 Force auto-calibration 0
(Default)
readout
  1 force auto-calibration without FIBARO Bypass 2
  2 force auto-calibration with FIBARO Bypass 2

Parameter Number

Parameter Size

Parameter Name

Parameter Values

160 1 Auto-calibration status (read-only parameter) 0
(Default)
calibration procedure not performed or the device operates on manual settings
  1 the device operates on auto-calibration settings

Parameter Number

Parameter Size

Parameter Name

Parameter Values

161 1 Burnt out bulb detection 0
(Default)
function disabled
  1 to 99 (1-99%, 1% step) – power variation

Parameter Number

Parameter Size

Parameter Name

Parameter Values

162 2 Time delay of a burnt out bulb and overload detection 0 detection of a burnt out bulb disabled
  1 to 255
(Default)
(1-255s, 1s step) – time delay

Parameter Number

Parameter Size

Parameter Name

Parameter Values

163 2 First button – Switch ON value sent to 2nd and 3rd association groups 0 to 99 value sent
  254 send value equal to the current level
  255
(Default)
value sent

Parameter Number

Parameter Size

Parameter Name

Parameter Values

164 2 Second button – Switch OFF value sent to 2nd and 3rd association groups 0 to 99
(Default)
value sent
  254 send value equal to the current level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

165 1 Double click – set level 0 to 99
(Default)
(0-99%, 1% step) – set level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

170 1 Load control mode 0 forced leading edge
  1 forced trailing edge
  2
(Default)
control mode selected automatically (based on auto-calibration)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

171 1 Load control mode recognized during auto-calibration (read only) 0
(Default)
leading edge
  1 trailing edge

Parameter Number

Parameter Size

Parameter Name

Parameter Values

172 1 ON/OFF mode 0 ON/OFF mode disabled (dimming is possible)
  1 ON/OFF mode enabled (dimming is not possible)
  2
(Default)
mode selected automatically

Parameter Number

Parameter Size

Parameter Name

Parameter Values

173 1 Dimmability of the load (read only) 0
(Default)
load recognized as dimmable
  1 load recognized as non-dimmable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

174 1 Soft-start functionality 0 no soft-start
  1
(Default)
short soft-start (0.1s)
  2 long soft-start (0.5s)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

175 1 Auto-calibration after power on 0 no auto-calibration after power on
  2 Auto-calibration after each power on
  3 Auto-calibration after each LOAD ERROR (no load, load failure, burnt out bulb), if parameter 176 is set to 1 also after SURGE (output overvoltage) and OVERCURRENT (output overcurrent)
  4 Auto-calibration after each power on or after each LOAD ERROR (no load, load failure, burnt out bulb), if parameter 176 is set to 1 also after SURGE (output overvoltage) and OVERCURRENT (output overcurrent)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

176 1 Behaviour after OVERCURRENT or SURGE 0 device permanently disabled until re-enabling by command or external switch
  1
(Default)
three attempts to turn on the load

Parameter Number

Parameter Size

Parameter Name

Parameter Values

177 2 Brightness level correction for flickering loads 0 automatic correction disabled
  1 to 254 (1-254s, 1s step) – duration of correction
  255
(Default)
automatic correction always enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

178 1 Method of calculating the active power 0
(Default)
measurement based on the standard algorithm
  1 approximation based on the calibration data
  2 approximation based on the control angle

Parameter Number

Parameter Size

Parameter Name

Parameter Values

179 2 Approximated power at the maximum brightness level 0 to 500
(Default)
(0-500W, 1W step) – power consumed by the load at the maximum brightness level.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 4 Overload safety switch 0 function disabled
  10 to 5000
(Default)
(1.0-500.0W, step 0.1W) – power threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Buttons orientation 0
(Default)
default (1st button brightens, 2nd button dims)
  1 reversed (1st button dims, 2nd button brightens)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 4 Alarm configuration - 1st slot 1 to 0 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 4 Alarm configuration - 2nd slot 1 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 4 Alarm configuration - 3rd slot 1 [MSB] – Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 4 Alarm configuration - 4th slot 0
(Default)
Notification Type
  1 [MSB] – Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 4 Alarm configuration - 5th slot 1 [MSB] – Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 [LSB] - action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 2 Alarm configuration – duration 0 infinite
  1 to 32400
(Default)
(1s-9h, 1s step) – duration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 First button – scenes sent 1 Key pressed 1 time
  2 Key pressed 2 time
  4 Key pressed 3 time
  8 Key hold down and key released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Second button – scenes sent 1 Key pressed 1 time
  2 Key pressed 2 time
  4 Key pressed 3 time
  8 Key hold down and key released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Power reports – include self-consumption 0
(Default)
Self-consumption not included
  1 Self-consumption included

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 2 Power reports – on change 0 reporting on change disabled
  1 to 500
(Default)
(1-500%, 1% step) – minimal change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 2 Power reports – periodic 0 periodic reports disabled
  30 to 32400
(Default)
(30s-9h, 1s step) – time interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 2 Energy reports – on change 0 reporting on change disabled
  1 to 500
(Default)
(0.01-5kWh, 0.01kWh step) – minimal change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Energy reports – periodic 0 periodic reports disabled
  30 to 32400
(Default)
(30s-9h, 1s step) – time interval