Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Remember device state | 0 | remains switched off after restoring power | |
1 (Default) |
restores remembered state after restoring power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | LED frame – power limit | 100 to 5000 (Default) |
(10.0-500.0W, step 0.1W) – power threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | LED frame – colour when ON | 0 | LED disabled | |
1 (Default) |
White | ||||
2 | Red | ||||
3 | Green | ||||
4 | Blue | ||||
5 | Yellow | ||||
6 | Cyan | ||||
7 | Magenta | ||||
8 | colour changes smoothly depending on measured power | ||||
9 | colour changes in steps depending on measured power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | LED frame – colour when OFF | 0 (Default) |
LED disabled | |
1 | White | ||||
2 | Red | ||||
3 | Green | ||||
4 | Blue | ||||
5 | Yellow | ||||
6 | Cyan | ||||
7 | Magenta | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | LED frame – brightness | 0 | LED disabled | |
1 to 100 (Default) |
(1-100% brightness) | ||||
101 | brightness directly proportional to set level | ||||
102 | brightness inversely proportional to set level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
150 | 1 | Minimum brightness level | 1 to 98 (Default) |
(1-98%, 1% step) – level of brightness | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 1 | Maximum brightness level | 2 to 99 (Default) |
(2-99%, 1% step) – level of brightness | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 1 | Incandescence level of dimmable compact fluorescent lamps | 1 to 99 (Default) |
(1-98%, 1% step) – level of brightness | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
153 | 2 | Incandescence time of dimmable compact fluorescent lamps | 0 to 255 (Default) |
(0-25.5s, 0.1s step) – incandescence time | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
154 | 1 | Automatic control – dimming step size | 1 to 99 (Default) |
(1-99%, 1% step) – dimming step | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
155 | 2 | Automatic control – time of dimming step | 0 to 255 (Default) |
This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic control. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
156 | 1 | Manual control – dimming step size | 1 (Default) |
[MSB] – Notification Type | |
2 | Notification Value | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
1 to 99 (Default) |
(1-99%, 1% step) – dimming step | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
157 | 2 | Manual control – time of dimming step | 0 to 255 (Default) |
(0-2.55s, 10ms step) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
158 | 2 | Auto-off functionality | 0 (Default) |
auto-off disabled | |
1 to 32767 | (1s-9.1h, 1s step) – auto-off time | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
159 | 1 | Force auto-calibration | 0 (Default) |
readout | |
1 | force auto-calibration without FIBARO Bypass 2 | ||||
2 | force auto-calibration with FIBARO Bypass 2 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
160 | 1 | Auto-calibration status (read-only parameter) | 0 (Default) |
calibration procedure not performed or the device operates on manual settings | |
1 | the device operates on auto-calibration settings | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
161 | 1 | Burnt out bulb detection | 0 (Default) |
function disabled | |
1 to 99 | (1-99%, 1% step) – power variation | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
162 | 2 | Time delay of a burnt out bulb and overload detection | 0 | detection of a burnt out bulb disabled | |
1 to 255 (Default) |
(1-255s, 1s step) – time delay | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
163 | 2 | First button – Switch ON value sent to 2nd and 3rd association groups | 0 to 99 | value sent | |
254 | send value equal to the current level | ||||
255 (Default) |
value sent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
164 | 2 | Second button – Switch OFF value sent to 2nd and 3rd association groups | 0 to 99 (Default) |
value sent | |
254 | send value equal to the current level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
165 | 1 | Double click – set level | 0 to 99 (Default) |
(0-99%, 1% step) – set level | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
170 | 1 | Load control mode | 0 | forced leading edge | |
1 | forced trailing edge | ||||
2 (Default) |
control mode selected automatically (based on auto-calibration) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
171 | 1 | Load control mode recognized during auto-calibration (read only) | 0 (Default) |
leading edge | |
1 | trailing edge | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
172 | 1 | ON/OFF mode | 0 | ON/OFF mode disabled (dimming is possible) | |
1 | ON/OFF mode enabled (dimming is not possible) | ||||
2 (Default) |
mode selected automatically | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
173 | 1 | Dimmability of the load (read only) | 0 (Default) |
load recognized as dimmable | |
1 | load recognized as non-dimmable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
174 | 1 | Soft-start functionality | 0 | no soft-start | |
1 (Default) |
short soft-start (0.1s) | ||||
2 | long soft-start (0.5s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
175 | 1 | Auto-calibration after power on | 0 | no auto-calibration after power on | |
2 | Auto-calibration after each power on | ||||
3 | Auto-calibration after each LOAD ERROR (no load, load failure, burnt out bulb), if parameter 176 is set to 1 also after SURGE (output overvoltage) and OVERCURRENT (output overcurrent) | ||||
4 | Auto-calibration after each power on or after each LOAD ERROR (no load, load failure, burnt out bulb), if parameter 176 is set to 1 also after SURGE (output overvoltage) and OVERCURRENT (output overcurrent) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
176 | 1 | Behaviour after OVERCURRENT or SURGE | 0 | device permanently disabled until re-enabling by command or external switch | |
1 (Default) |
three attempts to turn on the load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
177 | 2 | Brightness level correction for flickering loads | 0 | automatic correction disabled | |
1 to 254 | (1-254s, 1s step) – duration of correction | ||||
255 (Default) |
automatic correction always enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
178 | 1 | Method of calculating the active power | 0 (Default) |
measurement based on the standard algorithm | |
1 | approximation based on the calibration data | ||||
2 | approximation based on the control angle | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
179 | 2 | Approximated power at the maximum brightness level | 0 to 500 (Default) |
(0-500W, 1W step) – power consumed by the load at the maximum brightness level. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 4 | Overload safety switch | 0 | function disabled | |
10 to 5000 (Default) |
(1.0-500.0W, step 0.1W) – power threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Buttons orientation | 0 (Default) |
default (1st button brightens, 2nd button dims) | |
1 | reversed (1st button dims, 2nd button brightens) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 4 | Alarm configuration - 1st slot | 1 to 0 | [MSB] – Notification Type | |
2 | Notification Value | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 4 | Alarm configuration - 2nd slot | 1 | [MSB] – Notification Type | |
2 | Notification Value | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 4 | Alarm configuration - 3rd slot | 1 | [MSB] – Notification Type | |
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 4 | Alarm configuration - 4th slot | 0 (Default) |
Notification Type | |
1 | [MSB] – Notification Type | ||||
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
34 | 4 | Alarm configuration - 5th slot | 1 | [MSB] – Notification Type | |
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] - action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
35 | 2 | Alarm configuration – duration | 0 | infinite | |
1 to 32400 (Default) |
(1s-9h, 1s step) – duration | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | First button – scenes sent | 1 | Key pressed 1 time | |
2 | Key pressed 2 time | ||||
4 | Key pressed 3 time | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Second button – scenes sent | 1 | Key pressed 1 time | |
2 | Key pressed 2 time | ||||
4 | Key pressed 3 time | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Power reports – include self-consumption | 0 (Default) |
Self-consumption not included | |
1 | Self-consumption included | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 2 | Power reports – on change | 0 | reporting on change disabled | |
1 to 500 (Default) |
(1-500%, 1% step) – minimal change | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 2 | Power reports – periodic | 0 | periodic reports disabled | |
30 to 32400 (Default) |
(30s-9h, 1s step) – time interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Energy reports – on change | 0 | reporting on change disabled | |
1 to 500 (Default) |
(0.01-5kWh, 0.01kWh step) – minimal change | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Energy reports – periodic | 0 | periodic reports disabled | |
30 to 32400 (Default) |
(30s-9h, 1s step) – time interval | ||||