TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Wall Outlet (FGWOx-011)

Z-Wave Certification Number: ZC10-19056516


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Remember device state 0 remains switched off after restoring power
  1
(Default)
restores remembered state after restoring power

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 LED frame – power limit 500 to 36800
(Default)
(50.0-3680.0W, step 0.1W) – power threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 LED frame – colour when ON 0 LED disabled
  1 White
  2 Red
  3 Green
  4 Blue
  5 Yellow
  6 Cyan
  7 Magenta
  8
(Default)
colour changes smoothly depending on measured power
  9 colour changes in steps depending on measured power

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 LED frame – colour when OFF 0
(Default)
LED disabled
  1 White
  2 Red
  3 Green
  4 Blue
  5 Yellow
  6 Cyan
  7 Magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 LED frame – brightness 0 LED disabled
  1 to 100
(Default)
(1-100% brightness)
  101 brightness directly proportional to measured power
  102 brightness inversely proportional to measured power

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 4 Overload safety switch 0
(Default)
function disabled
  10 to 36800 (1.0-3680.0W, step 0.1W) – power threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 4 Alarm configuration - 1st slot 1 to 0 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 4 Alarm configuration - 2nd slot 1 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 4 Alarm configuration - 3rd slot 1 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 4 Alarm configuration - 4th slot 0
(Default)
Notification Type
  1 [MSB] – Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 4 Alarm configuration - 5th slot 1 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 2 Alarm configuration – duration 0 infinite
  1 to 32400
(Default)
(1s-9h, 1s step) – duration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

45 1 Associations – 2nd group 1 Power exceeds UP threshold
  2 Power drops below DOWN threshold
  3
(Default)
Power exceeds UP threshold or drops below DOWN threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

46 4 Associations – UP threshold 100 to 36800
(Default)
(10-3680W, 0.1W step) – power threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

47 2 Associations – UP threshold frame value 0 turn OFF
  1 to 99 set level
  255
(Default)
turn ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

48 4 Associations – DOWN threshold 0 to 36700
(Default)
(0-3670W, 0.1W step) – power threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

49 2 Associations – DOWN threshold frame value 0
(Default)
turn OFF
  1 to 99 set level
  255 turn ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Power reports – include self-consumption 0
(Default)
Self-consumption not included
  1 Self-consumption included

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 2 Power reports – on change 0 reporting on change disabled
  1 to 500
(Default)
(1-500%, 1% step) – minimal change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 2 Power reports – periodic 0 periodic reports disabled
  30 to 32400
(Default)
(30s-9h, 1s step) – time interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 2 Energy reports – on change 0 reporting on change disabled
  1 to 500
(Default)
(0.01-5kWh, 0.01kWh step) – minimal change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Energy reports – periodic 0 periodic reports disabled
  30 to 32400
(Default)
(30s-9h, 1s step) – time interval