There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Remember device state | 0 | remains switched off after restoring power | |
1 (Default) |
restores remembered state after restoring power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | LED frame – power limit | 500 to 30000 (Default) |
(50.0-3000.0W, step 0.1W) – power threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | LED frame – colour when ON | 0 | LED disabled | |
1 (Default) |
White | ||||
2 | Red | ||||
3 | Green | ||||
4 | Blue | ||||
5 | Yellow | ||||
6 | Cyan | ||||
7 | Magenta | ||||
8 | colour changes smoothly depending on measured power | ||||
9 | colour changes in steps depending on measured power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | LED frame – colour when OFF | 0 (Default) |
LED disabled | |
1 | White | ||||
2 | Red | ||||
3 | Green | ||||
4 | Blue | ||||
5 | Yellow | ||||
6 | Cyan | ||||
7 | Magenta | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | LED frame – brightness | 0 | LED disabled | |
1 to 100 (Default) |
(1-100% brightness) | ||||
101 | brightness directly proportional to measured power | ||||
102 | brightness inversely proportional to measured power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
150 | 1 | First channel – operating mode | 0 (Default) |
standard operation | |
1 | delayed OFF | ||||
2 | single pulse | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 1 | Second channel – operating mode | 0 (Default) |
standard operation | |
1 | delayed OFF | ||||
2 | single pulse | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 1 | First channel - reaction to switch for delayed OFF / pulse modes | 0 (Default) |
cancel mode and set default state | |
1 | no reaction - mode runs until it ends | ||||
2 | reset timer - start counting from the beginning | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
153 | 1 | Second channel - reaction to switch for delayed OFF / pulse modes | 0 (Default) |
cancel mode and set default state | |
1 | no reaction - mode runs until it ends | ||||
2 | reset timer - start counting from the beginning | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
154 | 2 | First channel - time parameter for delayed OFF / pulse modes | 0 | 0.1 second | |
1 to 32000 (Default) |
(1-32000s, 1s step) – time parameter | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
155 | 2 | Second channel - time parameter for delayed OFF / pulse modes | 0 | 0.1 second | |
1 to 32000 (Default) |
(1-32000s, 1s step) – time parameter | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
156 | 2 | First channel – Switch ON value sent to 2nd and 3rd association groups | 0 to 99 | 2nd association group | |
255 (Default) |
3rd association group | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
157 | 2 | First channel – Switch OFF value sent to 2nd and 3rd association groups | 0 to 99 (Default) |
2nd association group | |
255 | 3rd association group | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
158 | 2 | First channel – Double Click value sent to 2nd and 3rd association groups | 0 to 99 (Default) |
2nd association group | |
255 | 3rd association group | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
159 | 2 | Second channel – Switch ON value sent to 4th and 5th association groups | 0 to 99 | 4th association group | |
255 (Default) |
5th association group | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
160 | 2 | Second channel – Switch OFF value sent to 4th and 5th association groups | 0 to 99 (Default) |
4th association group | |
255 | 5th association group | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
161 | 2 | Second channel – Double Click value sent to 4th and 5th association groups | 0 to 99 (Default) |
4th association group | |
255 | 5th association group | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 4 | First channel – overload safety switch | 0 (Default) |
function disabled | |
10 to 36200 | (1.0-3620.0W, step 0.1W) – power threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Buttons operation | 1 | 1st and 2nd button toggle both channels | |
2 | 1st button turns both channels ON, 2nd button turns both channels OFF | ||||
3 (Default) |
1st button toggles 1st channel, 2nd button toggles 2nd channel | ||||
4 | 1st button single click turns 1st channel ON, 1st button double click turns 2nd channel ON, 2nd button single click turns both channels OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Buttons orientation | 0 (Default) |
default (1st button controls 1st channel, 2nd button controls 2nd channel) | |
1 | reversed (1st button controls 2nd channel, 2nd button controls 1st channel) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
25 | 1 | Outputs orientation | 0 (Default) |
default (Q1 - 1st channel, Q2 - 2nd channel) | |
1 | reversed (Q1 - 2nd channel, Q2 - 1st channel) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 4 | Second channel – overload safety switch | 0 (Default) |
function disabled | |
10 to 36200 | (1.0-3620.0W, step 0.1W) – power threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 4 | Alarm configuration - 1st slot | 1 to 0 | [MSB] – Notification Type | |
2 | Notification Value | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 4 | Alarm configuration - 2nd slot | 1 | [MSB] – Notification Type | |
2 | Notification Value | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 4 | Alarm configuration - 3rd slot | 1 | [MSB] – Notification Type | |
2 | Notification Value | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 4 | Alarm configuration - 4th slot | 0 (Default) |
Notification Type | |
1 | [MSB] – Notification Type | ||||
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
34 | 4 | Alarm configuration - 5th slot | 1 | [MSB] – Notification Type | |
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] - action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
35 | 2 | Alarm configuration – duration | 0 | infinite | |
1 to 32400 (Default) |
(1s-9h, 1s step) – duration | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | First button – scenes sent | 1 | Key pressed 1 time | |
2 | Key pressed 2 time | ||||
4 | Key pressed 3 time | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Second button – scenes sent | 1 | Key pressed 1 time | |
2 | Key pressed 2 time | ||||
4 | Key pressed 3 time | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Power reports – include self-consumption | 0 (Default) |
Self-consumption not included | |
1 | Self-consumption included | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 2 | Power reports for first channel – on change | 0 | reporting on change disabled | |
1 to 500 (Default) |
(1-500%, 1% step) – minimal change | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 2 | Power reports for first channel – periodic | 0 | periodic reports disabled | |
30 to 32400 (Default) |
(30s-9h, 1s step) – time interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 2 | Power reports for second channel – on change | 0 | reporting on change disabled | |
1 to 500 (Default) |
(1-500%, 1% step) – minimal change | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
64 | 2 | Power reports for second channel – periodic | 0 | periodic reports disabled | |
30 to 32400 (Default) |
(30s-9h, 1s step) – time interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Energy reports for first channel – on change | 0 | reporting on change disabled | |
1 to 500 (Default) |
(0.01-5kWh, 0.01kWh step) – minimal change | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Energy reports for first channel – periodic | 0 | periodic reports disabled | |
30 to 32400 (Default) |
(30s-9h, 1s step) – time interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
67 | 4 | Energy reports for second channel – on change | 0 | reporting on change disabled | |
1 to 500 (Default) |
(0.01-5kWh, 0.01kWh step) – minimal change | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
68 | 2 | Energy reports for second channel – periodic | 0 | periodic reports disabled | |
30 to 32400 (Default) |
(30s-9h, 1s step) – time interval | ||||