Z-Wave Products

There are over 4290 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Wall Roller Shutter (FGWREU-111)

Z-Wave Certification Number: ZC10-19056517


Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 LED frame – colour when moving 0 LED disabled
  1
(Default)
White
  2 Red
  3 Green
  4 Blue
  5 Yellow
  6 Cyan
  7 Magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 LED frame – colour when not moving 0
(Default)
LED disabled
  1 White
  2 Red
  3 Green
  4 Blue
  5 Yellow
  6 Cyan
  7 Magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 LED frame – brightness 0 LED disabled
  1 to 100
(Default)
(1-100% brightness)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

150 1 Force calibration 0
(Default)
device is not calibratedv
  1 device is calibrated
  2 force device calibration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

151 1 Operating mode 1
(Default)
roller blind (with positioning)
  2 Venetian blind (with positioning)
  5 roller blind with built-in driver
  6 roller blind with built-in driver (impulse)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

152 4 Venetian blind – time of full turn of the slats 0 to 65535
(Default)
(0 - 655.35s, every 0.01s) - time of turn

Parameter Number

Parameter Size

Parameter Name

Parameter Values

153 1 Set slats back to previous position 0 slats return to previously set position only in case of the main controller operation
  1
(Default)
slats return to previously set position in case of the main controller operation, momentary switch operation, or when the limit switch is reached
  2 slats return to previously set position in case of the main controller operation, momentary switch operation, when the limit switch is reached or after receiving the Switch Multilevel Stop control frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

154 2 Delay motor stop after reaching end switch 1 to 255
(Default)
(0.1s - 25.5 seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

155 2 Motor operation detection 0 no detection
  1 to 255
(Default)
(1-255W) - report interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

156 4 Time of up movement 1 to 65535
(Default)
(0.01 - 655.35 seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

157 4 Time of down movement 1 to 65535
(Default)
(0.01 - 655.35 seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Buttons orientation 0
(Default)
default (1st button UP, 2nd button DOWN)
  1 reversed (1st button DOWN, 2nd button UP)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 Outputs orientation 0
(Default)
(Q1 – UP, Q2 – DOWN)LED disabled
  1 reversed (Q1 – DOWN, Q2 – UP)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 4 Alarm configuration - 1st slot 1 to 0 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 4 Alarm configuration - 2nd slot 1 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 4 Alarm configuration - 3rd slot 1 [MSB] – Notification Type
  2 Notification Value
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 4 Alarm configuration - 4th slot 0
(Default)
Notification Type
  1 [MSB] – Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 [LSB] – action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 4 Alarm configuration - 5th slot 1 [MSB] – Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 [LSB] - action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 2 Alarm configuration – duration 0 infinite
  1 to 32400
(Default)
(1s-9h, 1s step) – duration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 First button – scenes sent 1 Key pressed 1 time
  2 Key pressed 2 time
  4 Key pressed 3 time
  8 Key hold down and key released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Second button – scenes sent 1 Key pressed 1 time
  2 Key pressed 2 time
  4 Key pressed 3 time
  8 Key hold down and key released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Power reports – include self-consumption 0
(Default)
Self-consumption not included
  1 Self-consumption included

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 2 Power reports – on change 0 reporting on change disabled
  1 to 500
(Default)
(1-500%, 1% step) – minimal change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 2 Power reports – periodic 0 periodic reports disabled
  30 to 32400
(Default)
(30s-9h, 1s step) – time interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 2 Energy reports – on change 0 reporting on change disabled
  1 to 500
(Default)
(0.01-5kWh, 0.01kWh step) – minimal change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Energy reports – periodic 0 periodic reports disabled
  30 to 32400
(Default)