There are over 4156 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Operating pushbutton(s) for dimmer | This parameter specifies which pushbutton(s) that shall be used to control the built-in dimmer. The parameter is a bitmask, so each of the values can be added together in order to have several pushbuttons to operate the dimmer. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 8 | No | No | No |
From |
To |
Description |
|||
0 | 0 | No local operation of the dimmer. | |||
1 | 1 | Pushbutton 1 controls the dimmer. | |||
2 | 2 | Pushbutton 2 controls the dimmer. | |||
4 | 4 | Pushbutton 3 controls the dimmer. | |||
8 | 8 | Pushbutton 4 controls the dimmer. | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Pushbutton debounce timer | Pushbutton input debounce time in 0.01 seconds resolution. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | 0 – 2.55 seconds. Default is 5, which equals to a debounce-filter on 50 milliseconds (0.05 seconds) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Pushbutton press threshold time | Specifies the time that a pushbutton must be activated before it is detected as pressed. Resolution is in 0.01 seconds. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | 0 – 2.55 seconds. Default is 20, which equals to 200 milliseconds (0.2 seconds). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Pushbutton held threshold time | Specifies the time that a pushbutton must have been activated before it is accepted as “held-down”. Resolution is 0.01 seconds. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | 0 – 2.55 seconds. Default is 50, which equals to 500 milliseconds (0,5 seconds). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 4 | Global brightness control | This parameter specifies a common brightness for each of the three base colours for all four pushbutton indicators. Byte 1: Red brightness. Byte 2: Green brightness. Byte 3: Blue brightness. Byte 4: Not used – must be set to 0. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 3: Brightness level for the blue colour in the 4 indicator groups. (Default is 255) | |||
0 | 0 | Byte 4: Not used – must be set to 0. | |||
0 | 255 | Byte1: Brightness level for the red colour in the 4 indicator groups. (Default is 255) | |||
0 | 255 | Byte 2: Brightness level for the green colour in the 4 indicator groups. (Default is 255) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 2 | Associations groups, transmission when included secure | This parameter specifies if commands are transmitted as a secure message for each of the association groups. This parameter is only used when the device is included in security mode (either S0 or S2). The values are bitmasks that can be added up to select several options. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
8191 | 0 | 8191 | No | No | No |
From |
To |
Description |
|||
0 | 0 | All messages in all groups are sent as insecure. | |||
1 | 1 | Messages in association group 2 is sent as secure. | |||
2 | 2 | Messages in association group 3 is sent as secure. | |||
4 | 4 | Messages in association group 4 is sent as secure. | |||
8 | 8 | Messages in association group 5 is sent as secure. | |||
16 | 16 | Messages in association group 6 is sent as secure. | |||
32 | 32 | Messages in association group 7 is sent as secure. | |||
64 | 64 | Messages in association group 8 is sent as secure. | |||
128 | 128 | Messages in association group 9 is sent as secure. | |||
256 | 256 | Messages in association group 10 is sent as secure. | |||
512 | 512 | Messages in association group 11 is sent as secure. | |||
1024 | 1024 | Messages in association group 12 is sent as secure. | |||
2048 | 2048 | Messages in association group 13 is sent as secure. | |||
4096 | 4096 | Messages in association group 14 is sent as secure. | |||
8191 | 8191 | Messages in all association groups are sent as secure. | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | Pushbutton 1 functionality | This parameter specifies the functionality of pushbutton 1. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 4 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Standard toggle-function, the state is switched between on and off, dimming up and down. | |||
1 | 1 | Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter. | |||
2 | 2 | Automatic turn on after the time has expired, the time is specified in the next configuration parameter. | |||
3 | 3 | Always turn off or dim down . Using this parameter, the pushbutton can only send ‘off’ or ‘dim down’ commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual) | |||
4 | 4 | Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’ commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 2 | Timer value for pushbutton 1 | This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
300 | 0 | 43200 | No | No | No |
From |
To |
Description |
|||
0 | 43200 | Specifies the time in seconds. Default is 300 = 5 minutes. | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | Multi-Level Switch Set values for pushbutton 1 | Byte 1: Enable / Disable Byte 2: Upper switch value Byte 3: Lower switch value Byte 4: Not used – must be set to 0. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Byte 1: Disabled – A single activation of the button will not result in commands are sent to devices in association group 4. | |||
0 | 99 | Byte 2: When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. | |||
0 | 99 | Byte 3: When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0) | |||
0 | 0 | Byte 4: Not used – must be set to 0 | |||
1 | 1 | Byte 1: Enabled – A single activation will result in commands are sent to devices in association group 4, they will receive commands with the values set below. (Default). | |||
255 | 255 | Byte 2: When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 1 | Binary Switch Set support for pushbutton 1 | This parameter specifies how received Binary Switch Set commands are handled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF | |||
1 | 1 | Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs | |||
2 | 2 | Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Duration of dimming | This parameter specifies the duration of a full regulation of the light from 0% to 100%. A regulation of the light with 1% will take 1/100 of the specified duration. This is used when a pushbutton is held-down for controlling the dimming, and when the dimming is fulfilled from other Z-Wave devices. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Immediately | |||
1 | 127 | Duration in seconds. | |||
128 | 255 | Duration in minutes (minus 127) from 1 – 128 minutes, where 128 is 1 minute | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | Pushbutton 1 LED indication | This parameter specifies how the LED indication is controlled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
7 | 0 | 7 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Internal LED control is disabled, only external commands control the indication | |||
1 | 1 | The LED indication follows the switch status | |||
2 | 2 | The LED indication follows the switch status – with inverted functionality | |||
3 | 3 | Same as 1 | |||
4 | 4 | Same as 2 | |||
5 | 5 | The LED indication follows the status of the internal dimmer, ON or OFF | |||
6 | 6 | The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF | |||
7 | 7 | The LED indicator is ON for 5 seconds when the pushbutton is activated | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
21 | 1 | Colour commands for pushbutton 1 LED indication | This parameter specifies how Command Class Switch Color commands are handled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated | |||
1 | 1 | Colour command sets the colour for OFF indication | |||
2 | 2 | Colour command sets the colour for ON indication | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
22 | 4 | ON indication RGB-saturation for pushbutton 1 | This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 4: LED indicator control; see the application note about this parameter. (Default is 0) | |||
0 | 255 | Byte 1: Specifies the saturation for the red LEDs. (Default is 0) | |||
0 | 255 | Byte 2: Specifies the saturation for the green LEDs. (Default is 0) | |||
0 | 255 | Byte 3: Specifies the saturation for the blue LEDs. (Default is 127) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
23 | 4 | OFF indication RGB-saturation for pushbutton 1 | This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
47 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 3: Specifies the saturation for the blue LEDs. (Default is 47) | |||
0 | 255 | Byte 4: LED indicator control; see the application note about this parameter. (Default is 0) | |||
0 | 255 | Byte 1: Specifies the saturation for the red LEDs. (Default is 47) | |||
0 | 255 | Byte 2: Specifies the saturation for the green LEDs. (Default is 47) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
24 | 1 | Pushbutton 2 functionality | This parameter specifies the functionality of pushbutton 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 4 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Standard toggle-function, the state is switched between on and off, dimming up and down. | |||
1 | 1 | Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter. | |||
2 | 2 | Automatic turn on after the time has expired, the time is specified in the next configuration parameter. | |||
3 | 3 | Always turn off or dim down. Using this parameter, the pushbutton can only send ‘off’ or ‘dim down’ commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual) | |||
4 | 4 | Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’ commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
25 | 2 | Timer value for pushbutton 2 | This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
300 | 0 | 43200 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Enhanced LED control is disabled | |||
0 | 43200 | Specifies the time in seconds. Default is 300 = 5 minutes | |||
1 | 1 | Enhanced LED control is enabled | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
26 | 4 | Multi-Level Switch Set values for pushbutton 2 | Byte 1: Enable / Disable. Byte 2: Upper switch value. Byte 3: Lower switch value. Byte 4: Not used – must be set to 0. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Byte 1: Disabled – A single activation of the pushbutton will not send commands to devices in association group 4 | |||
0 | 0 | Byte 4: Not used – must be set to 0. | |||
0 | 99 | Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0) | |||
0 | 99 | Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255) | |||
1 | 1 | Byte 1: Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default) | |||
255 | 255 | Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
27 | 1 | Binary Switch Set support for pushbutton 2 | This parameter specifies how received Binary Switch Set commands are handled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Binary Switch Set only controls the button indicator LEDs, ON/OFF | |||
1 | 1 | Binary Switch Set controls the internal switch status and the button indicator LEDs | |||
2 | 2 | Binary Switch Set is handled as if the user had activated the button, including transmission of commands via the association groups | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
28 | 1 | Pushbutton 2 LED indication | This parameter specifies how the LED indication is controlled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
7 | 0 | 7 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Internal LED control is disabled, only external commands control the indication | |||
1 | 1 | The LED indication follows the switch status | |||
2 | 2 | The LED indication follows the switch status – with inverted functionality | |||
3 | 3 | Same as 1 | |||
4 | 4 | Same as 2 | |||
5 | 5 | The LED indication follows the status of the internal dimmer, ON or OFF | |||
6 | 6 | The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF | |||
7 | 7 | The LED indicator is ON for 5 seconds when the pushbutton is activated | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
29 | 1 | Colour commands for pushbutton 2 LED indication | This parameter specifies how Command Class Switch Color commands is handled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated | |||
1 | 1 | Colour command sets the colour for OFF indication | |||
2 | 2 | Colour command sets the colour for ON indication | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Duration of on/off | This parameter specifies the duration when turning the light on or off. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Immediately | |||
1 | 127 | Time in seconds | |||
128 | 255 | Time in minutes (minus 127) from 1 – 128 minutes, where 128 is 1 minute | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
30 | 4 | ON indication RGB-saturation for pushbutton 2 | This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 1:Specifies the saturation for the red LEDs. (Default is 0) | |||
0 | 255 | Byte 2: Specifies the saturation for the green LEDs. (Default is 0) | |||
0 | 255 | Byte 3: Specifies the saturation for the blue LEDs. (Default is 127) | |||
0 | 255 | Byte 4: LED indicator control; see the application note about this parameter. (Default is 0) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
31 | 4 | OFF indication RGB-saturation for pushbutton 2 | This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 4: LED indicator control; see the application note about this parameter (Default is 0) | |||
0 | 255 | Byte 2: Specifies the saturation for the green LEDs (Default is 47) | |||
0 | 255 | Byte 3: Specifies the saturation for the blue LEDs (Default is 47) | |||
0 | 255 | Byte 1: Specifies the saturation for the red LEDs (Default is 47) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
32 | 1 | Pushbutton 3 functionality | This parameter specifies the functionality of pushbutton 3. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 4 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Standard toggle-function, the state is switched between on and off, dimming up and down | |||
1 | 1 | Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter. | |||
2 | 2 | Automatic turn on after the time has expired, the time is specified in the next configuration parameter. | |||
3 | 3 | Always turn off or dim down. Using this parameter, the pushbutton can only send ‘off’ or ‘dim down’ commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual) | |||
4 | 4 | Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’ commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
33 | 2 | Timer value for pushbutton 3 | This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
300 | 0 | 43200 | No | No | No |
From |
To |
Description |
|||
0 | 43200 | Specifies the time in seconds. Default is 300 = 5 minutes | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
34 | 4 | Multi-Level Switch Set values for pushbutton 3 | Byte 1: Enable / Disable. Byte 2: Upper switch value. Byte 3: Lower switch value. Byte 4: Not used – must be set to 0. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Byte 4: Not used – must be set to 0 | |||
0 | 99 | Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 0) | |||
0 | 0 | Byte 1: Disabled – A single activation of the pushbutton will not send commands to devices in association group 4 | |||
0 | 99 | Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 | |||
1 | 1 | Byte 1: Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (default) | |||
255 | 255 | Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 (default) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
35 | 1 | Binary Switch Set support for pushbutton 3 | This parameter specifies how received Binary Switch Set commands are handled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF | |||
1 | 1 | Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs | |||
2 | 2 | Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
36 | 1 | Pushbutton 3 LED indication | This parameter specifies how the LED indication is controlled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
7 | 0 | 7 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Internal LED control is disabled, only external commands control the indication | |||
1 | 1 | The LED indication follows the switch status | |||
2 | 2 | The LED indication follows the switch status – with inverted functionality | |||
3 | 3 | Same as 1 | |||
4 | 4 | Same as 2 | |||
5 | 5 | The LED indication follows the status of the internal dimmer, ON or OFF | |||
6 | 6 | The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF | |||
7 | 7 | The LED indicator is ON for 5 seconds when the pushbutton is activated | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
37 | 1 | Colour commands for pushbutton 3 LED indication | This parameter specifies how Command Class Switch Color commands is handled | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated | |||
1 | 1 | Colour command sets the colour for OFF indication | |||
2 | 2 | Colour command sets the colour for ON indication | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
38 | 4 | ON indication RGB-saturation for pushbutton 3 | This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
127 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 1: Specifies the saturation for the red LEDs. (Default is 0) | |||
0 | 255 | Byte 3: Specifies the saturation for the blue LEDs. (Default is 127) | |||
0 | 255 | Byte 2: Specifies the saturation for the green LEDs. (Default is 0) | |||
0 | 255 | Byte 4: LED indicator control; see the application note about this parameter. (Default is 0) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
39 | 4 | OFF indication RGB-saturation for pushbutton 3 | This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
47 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 2: Specifies the saturation for the green LEDs. (Default is 47) | |||
0 | 255 | Byte 3: Specifies the saturation for the blue LEDs. (Default is 47) | |||
0 | 255 | Byte 4: LED indicator control; see the application note about this parameter. (Default is 0) | |||
0 | 255 | Byte 1: Specifies the saturation for the red LEDs. (Default is 47). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Dimmer mode | The dimmer can work in three different modes: on/off, leading edge or trailing edge. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | No dimming, only on/off (0/100%). | |||
1 | 1 | Trailing edge dimming | |||
2 | 2 | Leading edge dimming | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 1 | Pushbutton 4 functionality | This parameter specifies the functionality of pushbutton 4. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 4 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Standard toggle-function, the state is switched between on and off, dimming up and down | |||
1 | 1 | Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter. | |||
2 | 2 | Automatic turn on after the time has expired, the time is specified in the next configuration parameter. | |||
3 | 3 | Always turn off or dim down. Using this parameter, the pushbutton can only send ‘off’ or ‘dim down’ commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual). | |||
4 | 4 | Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’ commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
41 | 2 | Timer value for pushbutton 4 | This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
300 | 0 | 43200 | No | No | No |
From |
To |
Description |
|||
0 | 43200 | Specifies the time in seconds. Default is 300 = 5 minutes | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
42 | 4 | Multi-Level Switch Set values for pushbutton 4 | Byte 1: Enable / Disable. Byte 2: Upper switch value. Byte 3: Lower switch value. Byte 4: Not used – must be set to 0. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Byte 4: Not used – must be set to 0. | |||
0 | 99 | Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 | |||
0 | 0 | Byte 1: Disabled – A single activation of the pushbutton will not send commands to devices in association group 4. | |||
0 | 99 | Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0) | |||
1 | 1 | Byte 1: Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default). | |||
255 | 255 | Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
43 | 1 | Binary Switch Set support for pushbutton 4 | This parameter specifies how received Binary Switch Set commands are handled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF | |||
1 | 1 | Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs | |||
2 | 2 | Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
44 | 1 | Pushbutton 4 LED indication | This parameter specifies how the LED indication is controlled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
7 | 0 | 7 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Internal LED control is disabled, only external commands control the indication. | |||
1 | 1 | The LED indication follows the switch status | |||
2 | 2 | The LED indication follows the switch status – with inverted functionality | |||
3 | 3 | Same as 1 | |||
4 | 4 | Same as 2 | |||
5 | 5 | The LED indication follows the status of the internal dimmer, ON or OFF | |||
6 | 6 | The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF | |||
7 | 7 | The LED indicator is ON for 5 seconds when the pushbutton is activated | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
45 | 1 | Colour commands for pushbutton 4 LED indication | This parameter specifies how Command Class Switch Color commands are handled. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated | |||
1 | 1 | Colour command sets the colour for OFF indication | |||
2 | 2 | Colour command sets the colour for ON indication | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
46 | 4 | ON indication RGB-saturation for pushbutton 4 | This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 1: Specifies the saturation for the red LEDs. (Default is 0) | |||
0 | 255 | Byte 2: Specifies the saturation for the green LEDs. (Default is 0) | |||
0 | 255 | Byte 3: Specifies the saturation for the blue LEDs. (Default is 127) | |||
0 | 255 | Byte 4: LED indicator control; see the application note about this parameter. (Default is 0) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
47 | 4 | OFF indication RGB-saturation for pushbutton 4 | This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
From |
To |
Description |
|||
0 | 255 | Byte 1: Specifies the saturation for the red LEDs. (Default is 47) | |||
0 | 255 | Byte 2: Specifies the saturation for the green LEDs. (Default is 47) | |||
0 | 255 | Byte 4: LED indicator control; see the application note about this parameter. (Default is 0) | |||
0 | 255 | Byte 3: Specifies the saturation for the blue LEDs. (Default is 47) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Dimmer minimum level | This parameter specifies the actual level of the dimmer output when set to 0%. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 99 | No | No | No |
From |
To |
Description |
|||
0 | 99 | Corresponds to 0 – 99% | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Dimmer maximum level | This parameter specifies the actual level of the dimmer output when set to 99%. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
99 | 0 | 99 | No | No | No |
From |
To |
Description |
|||
0 | 99 | Corresponds to 0 – 99% | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Central Scene notifications | This parameter can be used for disabling Central Scene notifications. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Notifications are disabled | |||
1 | 1 | Notifications are enabled | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Double-activation functionality | This parameter specifies the reaction when double-activating the pushbuttons. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Double-activation disabled | |||
1 | 1 | Double-activation sets light to 100% | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Triple-activation of pushbutton 1 | This parameter can be used for disabling the Z-Wave network add/remove process when triple-activating pushbutton 1. If disabled, the triple-activation functionality can be used as a Central Scene notification. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Triple-activation of pushbutton 1, does not start the add/remove process. | |||
1 | 1 | Triple-activation of pushbutton 1, starts the add/remove process | |||