There are over 4156 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Dimmer Wall Switch (ZDB5100)

Z-Wave Certification Number: ZC10-19066525


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Operating pushbutton(s) for dimmer This parameter specifies which pushbutton(s) that shall be used to control the built-in dimmer. The parameter is a bitmask, so each of the values can be added together in order to have several pushbuttons to operate the dimmer.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 8 No No No

From

 

To

Description

0   0 No local operation of the dimmer.
1   1 Pushbutton 1 controls the dimmer.
2   2 Pushbutton 2 controls the dimmer.
4   4 Pushbutton 3 controls the dimmer.
8   8 Pushbutton 4 controls the dimmer.

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Pushbutton debounce timer Pushbutton input debounce time in 0.01 seconds resolution.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 255 No No No

From

 

To

Description

0   255 0 – 2.55 seconds. Default is 5, which equals to a debounce-filter on 50 milliseconds (0.05 seconds)

Parameter Number

Parameter Size

Parameter Name

Description

12 1 Pushbutton press threshold time Specifies the time that a pushbutton must be activated before it is detected as pressed. Resolution is in 0.01 seconds.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 0 255 No No No

From

 

To

Description

0   255 0 – 2.55 seconds. Default is 20, which equals to 200 milliseconds (0.2 seconds).

Parameter Number

Parameter Size

Parameter Name

Description

13 1 Pushbutton held threshold time Specifies the time that a pushbutton must have been activated before it is accepted as “held-down”. Resolution is 0.01 seconds.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 0 255 No No No

From

 

To

Description

0   255 0 – 2.55 seconds. Default is 50, which equals to 500 milliseconds (0,5 seconds).

Parameter Number

Parameter Size

Parameter Name

Description

14 4 Global brightness control This parameter specifies a common brightness for each of the three base colours for all four pushbutton indicators. Byte 1: Red brightness. Byte 2: Green brightness. Byte 3: Blue brightness. Byte 4: Not used – must be set to 0.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

From

 

To

Description

0   255 Byte 3: Brightness level for the blue colour in the 4 indicator groups. (Default is 255)
0   0 Byte 4: Not used – must be set to 0.
0   255 Byte1: Brightness level for the red colour in the 4 indicator groups. (Default is 255)
0   255 Byte 2: Brightness level for the green colour in the 4 indicator groups. (Default is 255)

Parameter Number

Parameter Size

Parameter Name

Description

15 2 Associations groups, transmission when included secure This parameter specifies if commands are transmitted as a secure message for each of the association groups. This parameter is only used when the device is included in security mode (either S0 or S2). The values are bitmasks that can be added up to select several options.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

8191 0 8191 No No No

From

 

To

Description

0   0 All messages in all groups are sent as insecure.
1   1 Messages in association group 2 is sent as secure.
2   2 Messages in association group 3 is sent as secure.
4   4 Messages in association group 4 is sent as secure.
8   8 Messages in association group 5 is sent as secure.
16   16 Messages in association group 6 is sent as secure.
32   32 Messages in association group 7 is sent as secure.
64   64 Messages in association group 8 is sent as secure.
128   128 Messages in association group 9 is sent as secure.
256   256 Messages in association group 10 is sent as secure.
512   512 Messages in association group 11 is sent as secure.
1024   1024 Messages in association group 12 is sent as secure.
2048   2048 Messages in association group 13 is sent as secure.
4096   4096 Messages in association group 14 is sent as secure.
8191   8191 Messages in all association groups are sent as secure.

Parameter Number

Parameter Size

Parameter Name

Description

16 1 Pushbutton 1 functionality This parameter specifies the functionality of pushbutton 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 4 No No No

From

 

To

Description

0   0 Standard toggle-function, the state is switched between on and off, dimming up and down.
1   1 Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter.
2   2 Automatic turn on after the time has expired, the time is specified in the next configuration parameter.
3   3 Always turn off or dim down . Using this parameter, the pushbutton can only send ‘off’ or ‘dim down’ commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual)
4   4 Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’ commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual)

Parameter Number

Parameter Size

Parameter Name

Description

17 2 Timer value for pushbutton 1 This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

300 0 43200 No No No

From

 

To

Description

0   43200 Specifies the time in seconds. Default is 300 = 5 minutes.

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Multi-Level Switch Set values for pushbutton 1 Byte 1: Enable / Disable Byte 2: Upper switch value Byte 3: Lower switch value Byte 4: Not used – must be set to 0.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

From

 

To

Description

0   0 Byte 1: Disabled – A single activation of the button will not result in commands are sent to devices in association group 4.
0   99 Byte 2: When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 4.
0   99 Byte 3: When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0)
0   0 Byte 4: Not used – must be set to 0
1   1 Byte 1: Enabled – A single activation will result in commands are sent to devices in association group 4, they will receive commands with the values set below. (Default).
255   255 Byte 2: When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255)

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Binary Switch Set support for pushbutton 1 This parameter specifies how received Binary Switch Set commands are handled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

From

 

To

Description

0   0 Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF
1   1 Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs
2   2 Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Duration of dimming This parameter specifies the duration of a full regulation of the light from 0% to 100%. A regulation of the light with 1% will take 1/100 of the specified duration. This is used when a pushbutton is held-down for controlling the dimming, and when the dimming is fulfilled from other Z-Wave devices.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 255 No No No

From

 

To

Description

0   0 Immediately
1   127 Duration in seconds.
128   255 Duration in minutes (minus 127) from 1 – 128 minutes, where 128 is 1 minute

Parameter Number

Parameter Size

Parameter Name

Description

20 1 Pushbutton 1 LED indication This parameter specifies how the LED indication is controlled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

7 0 7 No No No

From

 

To

Description

0   0 Internal LED control is disabled, only external commands control the indication
1   1 The LED indication follows the switch status
2   2 The LED indication follows the switch status – with inverted functionality
3   3 Same as 1
4   4 Same as 2
5   5 The LED indication follows the status of the internal dimmer, ON or OFF
6   6 The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF
7   7 The LED indicator is ON for 5 seconds when the pushbutton is activated

Parameter Number

Parameter Size

Parameter Name

Description

21 1 Colour commands for pushbutton 1 LED indication This parameter specifies how Command Class Switch Color commands are handled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

From

 

To

Description

0   0 Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated
1   1 Colour command sets the colour for OFF indication
2   2 Colour command sets the colour for ON indication

Parameter Number

Parameter Size

Parameter Name

Description

22 4 ON indication RGB-saturation for pushbutton 1 This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

From

 

To

Description

0   255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)
0   255 Byte 1: Specifies the saturation for the red LEDs. (Default is 0)
0   255 Byte 2: Specifies the saturation for the green LEDs. (Default is 0)
0   255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 127)

Parameter Number

Parameter Size

Parameter Name

Description

23 4 OFF indication RGB-saturation for pushbutton 1 This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

47 0 255 No No No

From

 

To

Description

0   255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 47)
0   255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)
0   255 Byte 1: Specifies the saturation for the red LEDs. (Default is 47)
0   255 Byte 2: Specifies the saturation for the green LEDs. (Default is 47)

Parameter Number

Parameter Size

Parameter Name

Description

24 1 Pushbutton 2 functionality This parameter specifies the functionality of pushbutton 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 4 No No No

From

 

To

Description

0   0 Standard toggle-function, the state is switched between on and off, dimming up and down.
1   1 Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter.
2   2 Automatic turn on after the time has expired, the time is specified in the next configuration parameter.
3   3 Always turn off or dim down. Using this parameter, the pushbutton can only send ‘off’ or ‘dim down’ commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual)
4   4 Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’ commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual)

Parameter Number

Parameter Size

Parameter Name

Description

25 2 Timer value for pushbutton 2 This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

300 0 43200 No No No

From

 

To

Description

0   0 Enhanced LED control is disabled
0   43200 Specifies the time in seconds. Default is 300 = 5 minutes
1   1 Enhanced LED control is enabled

Parameter Number

Parameter Size

Parameter Name

Description

26 4 Multi-Level Switch Set values for pushbutton 2 Byte 1: Enable / Disable. Byte 2: Upper switch value. Byte 3: Lower switch value. Byte 4: Not used – must be set to 0.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

From

 

To

Description

0   0 Byte 1: Disabled – A single activation of the pushbutton will not send commands to devices in association group 4
0   0 Byte 4: Not used – must be set to 0.
0   99 Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0)
0   99 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255)
1   1 Byte 1: Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default)
255   255 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255)

Parameter Number

Parameter Size

Parameter Name

Description

27 1 Binary Switch Set support for pushbutton 2 This parameter specifies how received Binary Switch Set commands are handled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

From

 

To

Description

0   0 Binary Switch Set only controls the button indicator LEDs, ON/OFF
1   1 Binary Switch Set controls the internal switch status and the button indicator LEDs
2   2 Binary Switch Set is handled as if the user had activated the button, including transmission of commands via the association groups

Parameter Number

Parameter Size

Parameter Name

Description

28 1 Pushbutton 2 LED indication This parameter specifies how the LED indication is controlled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

7 0 7 No No No

From

 

To

Description

0   0 Internal LED control is disabled, only external commands control the indication
1   1 The LED indication follows the switch status
2   2 The LED indication follows the switch status – with inverted functionality
3   3 Same as 1
4   4 Same as 2
5   5 The LED indication follows the status of the internal dimmer, ON or OFF
6   6 The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF
7   7 The LED indicator is ON for 5 seconds when the pushbutton is activated

Parameter Number

Parameter Size

Parameter Name

Description

29 1 Colour commands for pushbutton 2 LED indication This parameter specifies how Command Class Switch Color commands is handled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

From

 

To

Description

0   0 Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated
1   1 Colour command sets the colour for OFF indication
2   2 Colour command sets the colour for ON indication

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Duration of on/off This parameter specifies the duration when turning the light on or off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

From

 

To

Description

0   0 Immediately
1   127 Time in seconds
128   255 Time in minutes (minus 127) from 1 – 128 minutes, where 128 is 1 minute

Parameter Number

Parameter Size

Parameter Name

Description

30 4 ON indication RGB-saturation for pushbutton 2 This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

From

 

To

Description

0   255 Byte 1:Specifies the saturation for the red LEDs. (Default is 0)
0   255 Byte 2: Specifies the saturation for the green LEDs. (Default is 0)
0   255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 127)
0   255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)

Parameter Number

Parameter Size

Parameter Name

Description

31 4 OFF indication RGB-saturation for pushbutton 2 This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

From

 

To

Description

0   255 Byte 4: LED indicator control; see the application note about this parameter (Default is 0)
0   255 Byte 2: Specifies the saturation for the green LEDs (Default is 47)
0   255 Byte 3: Specifies the saturation for the blue LEDs (Default is 47)
0   255 Byte 1: Specifies the saturation for the red LEDs (Default is 47)

Parameter Number

Parameter Size

Parameter Name

Description

32 1 Pushbutton 3 functionality This parameter specifies the functionality of pushbutton 3.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 4 No No No

From

 

To

Description

0   0 Standard toggle-function, the state is switched between on and off, dimming up and down
1   1 Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter.
2   2 Automatic turn on after the time has expired, the time is specified in the next configuration parameter.
3   3 Always turn off or dim down. Using this parameter, the pushbutton can only send ‘off’ or ‘dim down’ commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual)
4   4 Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’ commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual)

Parameter Number

Parameter Size

Parameter Name

Description

33 2 Timer value for pushbutton 3 This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

300 0 43200 No No No

From

 

To

Description

0   43200 Specifies the time in seconds. Default is 300 = 5 minutes

Parameter Number

Parameter Size

Parameter Name

Description

34 4 Multi-Level Switch Set values for pushbutton 3 Byte 1: Enable / Disable. Byte 2: Upper switch value. Byte 3: Lower switch value. Byte 4: Not used – must be set to 0.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

From

 

To

Description

0   0 Byte 4: Not used – must be set to 0
0   99 Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 0)
0   0 Byte 1: Disabled – A single activation of the pushbutton will not send commands to devices in association group 4
0   99 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4
1   1 Byte 1: Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (default)
255   255 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 (default)

Parameter Number

Parameter Size

Parameter Name

Description

35 1 Binary Switch Set support for pushbutton 3 This parameter specifies how received Binary Switch Set commands are handled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

From

 

To

Description

0   0 Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF
1   1 Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs
2   2 Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups

Parameter Number

Parameter Size

Parameter Name

Description

36 1 Pushbutton 3 LED indication This parameter specifies how the LED indication is controlled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

7 0 7 No No No

From

 

To

Description

0   0 Internal LED control is disabled, only external commands control the indication
1   1 The LED indication follows the switch status
2   2 The LED indication follows the switch status – with inverted functionality
3   3 Same as 1
4   4 Same as 2
5   5 The LED indication follows the status of the internal dimmer, ON or OFF
6   6 The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF
7   7 The LED indicator is ON for 5 seconds when the pushbutton is activated

Parameter Number

Parameter Size

Parameter Name

Description

37 1 Colour commands for pushbutton 3 LED indication This parameter specifies how Command Class Switch Color commands is handled

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

From

 

To

Description

0   0 Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated
1   1 Colour command sets the colour for OFF indication
2   2 Colour command sets the colour for ON indication

Parameter Number

Parameter Size

Parameter Name

Description

38 4 ON indication RGB-saturation for pushbutton 3 This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

127 0 255 No No No

From

 

To

Description

0   255 Byte 1: Specifies the saturation for the red LEDs. (Default is 0)
0   255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 127)
0   255 Byte 2: Specifies the saturation for the green LEDs. (Default is 0)
0   255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)

Parameter Number

Parameter Size

Parameter Name

Description

39 4 OFF indication RGB-saturation for pushbutton 3 This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

47 0 255 No No No

From

 

To

Description

0   255 Byte 2: Specifies the saturation for the green LEDs. (Default is 47)
0   255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 47)
0   255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)
0   255 Byte 1: Specifies the saturation for the red LEDs. (Default is 47).

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Dimmer mode The dimmer can work in three different modes: on/off, leading edge or trailing edge.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

From

 

To

Description

0   0 No dimming, only on/off (0/100%).
1   1 Trailing edge dimming
2   2 Leading edge dimming

Parameter Number

Parameter Size

Parameter Name

Description

40 1 Pushbutton 4 functionality This parameter specifies the functionality of pushbutton 4.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 4 No No No

From

 

To

Description

0   0 Standard toggle-function, the state is switched between on and off, dimming up and down
1   1 Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter.
2   2 Automatic turn on after the time has expired, the time is specified in the next configuration parameter.
3   3 Always turn off or dim down. Using this parameter, the pushbutton can only send ‘off’ or ‘dim down’ commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual).
4   4 Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’ commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual).

Parameter Number

Parameter Size

Parameter Name

Description

41 2 Timer value for pushbutton 4 This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

300 0 43200 No No No

From

 

To

Description

0   43200 Specifies the time in seconds. Default is 300 = 5 minutes

Parameter Number

Parameter Size

Parameter Name

Description

42 4 Multi-Level Switch Set values for pushbutton 4 Byte 1: Enable / Disable. Byte 2: Upper switch value. Byte 3: Lower switch value. Byte 4: Not used – must be set to 0.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

From

 

To

Description

0   0 Byte 4: Not used – must be set to 0.
0   99 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4
0   0 Byte 1: Disabled – A single activation of the pushbutton will not send commands to devices in association group 4.
0   99 Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0)
1   1 Byte 1: Enabled – A single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default).
255   255 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default)

Parameter Number

Parameter Size

Parameter Name

Description

43 1 Binary Switch Set support for pushbutton 4 This parameter specifies how received Binary Switch Set commands are handled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

From

 

To

Description

0   0 Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF
1   1 Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs
2   2 Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups

Parameter Number

Parameter Size

Parameter Name

Description

44 1 Pushbutton 4 LED indication This parameter specifies how the LED indication is controlled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

7 0 7 No No No

From

 

To

Description

0   0 Internal LED control is disabled, only external commands control the indication.
1   1 The LED indication follows the switch status
2   2 The LED indication follows the switch status – with inverted functionality
3   3 Same as 1
4   4 Same as 2
5   5 The LED indication follows the status of the internal dimmer, ON or OFF
6   6 The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF
7   7 The LED indicator is ON for 5 seconds when the pushbutton is activated

Parameter Number

Parameter Size

Parameter Name

Description

45 1 Colour commands for pushbutton 4 LED indication This parameter specifies how Command Class Switch Color commands are handled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

From

 

To

Description

0   0 Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated
1   1 Colour command sets the colour for OFF indication
2   2 Colour command sets the colour for ON indication

Parameter Number

Parameter Size

Parameter Name

Description

46 4 ON indication RGB-saturation for pushbutton 4 This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

From

 

To

Description

0   255 Byte 1: Specifies the saturation for the red LEDs. (Default is 0)
0   255 Byte 2: Specifies the saturation for the green LEDs. (Default is 0)
0   255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 127)
0   255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)

Parameter Number

Parameter Size

Parameter Name

Description

47 4 OFF indication RGB-saturation for pushbutton 4 This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%). Byte 1: Colour saturation, red. Byte 2: Colour saturation, green. Byte 3: Colour saturation, blue. Byte 4: LED control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

From

 

To

Description

0   255 Byte 1: Specifies the saturation for the red LEDs. (Default is 47)
0   255 Byte 2: Specifies the saturation for the green LEDs. (Default is 47)
0   255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)
0   255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 47)

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Dimmer minimum level This parameter specifies the actual level of the dimmer output when set to 0%.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 99 No No No

From

 

To

Description

0   99 Corresponds to 0 – 99%

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Dimmer maximum level This parameter specifies the actual level of the dimmer output when set to 99%.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 0 99 No No No

From

 

To

Description

0   99 Corresponds to 0 – 99%

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Central Scene notifications This parameter can be used for disabling Central Scene notifications.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   0 Notifications are disabled
1   1 Notifications are enabled

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Double-activation functionality This parameter specifies the reaction when double-activating the pushbuttons.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   0 Double-activation disabled
1   1 Double-activation sets light to 100%

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Triple-activation of pushbutton 1 This parameter can be used for disabling the Z-Wave network add/remove process when triple-activating pushbutton 1. If disabled, the triple-activation functionality can be used as a Central Scene notification.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   0 Triple-activation of pushbutton 1, does not start the add/remove process.
1   1 Triple-activation of pushbutton 1, starts the add/remove process