Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Setting to disable alarm | 0 (Default) |
Can be disabled by 3x tapping Action Button within 1 second | |
1 | Can be disabled when receives a State Idle corresponding to the alarm. Note: If Access Control is enable, it also can be disabled when receives the reversal state of window/door. | ||||
10 to 255 | Sets the duration of the alarm in seconds(i.e. Customer sets this setting to 50, the alarm state of the Switch will disable after 50 seconds) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | Configure which meter reading will be periodically report via Lifeline. | 1 | Power Consumption | |
2 | Power | ||||
4 | Voltage | ||||
8 | Current | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Configure the sending frequency of Meter Report. | 0 | Disable | |
600 to 2592000 (Default) |
600-2592000s. (10minute-30day) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | LED blinking frequency | 1 to 9 (Default) |
Set amount of blinks per seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 2 | Start or stop LED blinking.(Write Only) | 0 (Default) |
Stop blinking. | |
1 to 255 | Set the duration and start the blinking process. * This sets the timeframe of blinking in seconds. * Once the duration ends, the blinking will stop. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Action in case of power out. | 0 (Default) |
Last status | |
1 | Switch is on | ||||
2 | Switch is off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 1 | Factory Reset or Initialization (Write Only) | 1431655765 | Factory Reset: Restore the product to factory settings and remove from the network. | |
0 (Default) |
Initialization: Initialize all configuration parameters to default values. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Over-load protection | 0 | Disable over-load protection | |
1 to 2415 (Default) |
Threshold power is 1-2145W | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Alarm Response | 0 (Default) |
Disable, no reaction to alarm settings | |
1 | Switch is ON | ||||
2 | Switch is OFF | ||||
3 | Switch will turn ON in 5 seconds, and then turn OFF in 5 seconds in a cycle until user disables the alarm manually | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | Configure what command will be sent via Lifeline when switch state has changed. | 0 | None | |
1 | Basic Report | ||||
2 (Default) |
Binary Switch Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
81 | 1 | Load Indicator Mode setting. | 0 | Disable Mode | |
1 | Night Light Mode | ||||
2 (Default) |
ON/OFF Mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
82 | 4 | Configure the enable and disable time of Night Light Mode | 0 to 2147483647 (Default) |
Value1=Enable Hour, Value2=Enable Minute, Value3=Disable Hour, Value4=Disabale Minute | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Alarm Settings | 1 | Access Control trigger state | |
256 | Smoke Alarm | ||||
512 | CO Alarm | ||||
1024 | CO2 Alarm | ||||
2048 | Heart Alarm | ||||
4096 | Water Alarm | ||||
8192 | Access Control | ||||
16384 | Home Security | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
91 | 2 | Threshold Power (W) for inducing automatic report. | 0 (Default) |
Disable | |
1 to 2300 | 1-2300W | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
92 | 2 | Threshold Power Consumption (kWh) for inducing automatic report. | 0 (Default) |
Disable | |
1 to 10000 | 1-10000kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
93 | 1 | Threshold Current (A) for inducing automatic report. | 0 (Default) |
Disable | |
1 to 100 | 0.1-10A. Unit is 0.1A. | ||||