TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Dimmer Switch (LZW31)

Z-Wave Certification Number: ZC10-19096763


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Dimming Speed 0 to 100
(Default)
Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Default Level (Z-Wave) 0
(Default)
Previous Level
  1 to 100 Percentage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Power On State 0
(Default)
Off
  1 to 100 Turns On to a Specific Percentage Level
  101 Turns On to Last Percentage Level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Association Behavior 1 Local
  2 3-Way
  3 3-Way + Local
  4 Z-Wave HUB
  5 Z-Wave HUB + Local
  6 Z-Wave HUB + 3-Way
  7 Z-Wave HUB + Local + 3-Way
  8 Timer
  9 Timer + Local
  10 Timer + 3-Way
  11 Timer + 3-Way + Local
  12 Timer + Z-Wave HUB
  13 Timer + Z-Wave HUB + Local
  14 Timer + Z-Wave HUB + 3-Way
  15
(Default)
All

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 LED Indicator Color 170
(Default)
Default Color (Blue)
  0 to 255
(Default)
Colors

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 LED Indicator Intensity 0 Disabled
  1 to 32767
(Default)
Seconds
  0 Off
  1 to 4 Low Intensity
  5 to 7
(Default)
Medium Intensity
  8 to 10 High Intensity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 LED Indicator Intensity (When Off) 0 Off
  1 to 4
(Default)
Low Intensity
  5 to 7 Medium Intensity
  8 to 10 High Intensity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 4 LED Strip Effect 0
(Default)
No Effect

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Timeout for LED Notifications 0 Always Off
  1 to 10
(Default)
Seconds after Dim Level is Adjusted

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Dimming Speed (Z-Wave) 0 Instant On
  1 to 100 Seconds
  101
(Default)
Keeps in sync with Parameter 1

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Ramp Rate 0 Instant On
  1 to 100 Seconds
  101
(Default)
Keeps in sync with Parameter 1

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Ramp Rate (Z-Wave) 0 Instant On
  1 to 100 Seconds
  101
(Default)
Keeps in sync with Parameter 1

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Minimum Dim Level 1 to 45
(Default)
Percentage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Maximum Dim Level 55 to 100 Percentage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Invert Switch 0
(Default)
Disabled
  1 Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Auto Off Timer 0 to 32767
(Default)
automatically turns off after so many seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Default Level (Local) 0
(Default)
Previous Level
  1 to 100 Percentage