There are over 4376 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: On/Off Switch (Red Series) (LZW30-SN)

Z-Wave Certification Number: ZC10-19086700


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Power On State 0
(Default)
When Power is restored, switch is OFF
  1 to 100 When Power is restored, switch turns ON to a certain dim level
  101 When Power is restored, switch reverts to last status

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Active Power Alerts 0 Disabled
  1 to 100
(Default)
Percentage of previous report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Periodic Power + Energy Reports 0 to 32767
(Default)
Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Energy Reports 0 Disabled
  1 to 100
(Default)
Percentage of previous report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Invert Switch 0
(Default)
Disabled
  1 Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 2 Auto Off Timer 0
(Default)
Disabled
  1 to 32767 Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Association Behavior 1 Local
  2 3-Way
  3 3-Way + Local
  4 Z-Wave HUB
  5 Z-Wave HUB + Local
  6 Z-Wave HUB + 3-Way
  7 Z-Wave HUB + Local
  8 Timer
  9 Timer + Local
  10 Timer + 3-Way
  11 Timer + Local
  12 Timer + Z-Wave HUB
  13 Timer + Local
  14 Timer + Z-Wave HUB
  15
(Default)
All

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 LED Indicator Color 0 to 255
(Default)
Hue Color Circle
  170
(Default)
Blue

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 LED Indicator Intensity 0 Off
  1 to 3 Low Intensity
  4 to 7
(Default)
Medium Intensity
  8 to 10 High Intensity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 LED Indicator Intensity (When Off) 0 Off
  1 to 3
(Default)
Low Intensity
  4 to 7 Medium Intensity
  8 to 10 High Intensity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 4 LED Strip Effect 0
(Default)
Please see website for matrix