There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | PM25_Delta_Level | 0 to 127 (Default) |
=0 Turn off report >=1 Report when change > n * 1ug/m3 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Smoke_Timer | 35 to 32767 (Default) |
>=35 Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | PIR_Timer | 35 to 32767 (Default) |
>=35 Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | PM25_Timer | 35 to 32767 (Default) |
>=35Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | CO2_Timer | 35 to 32767 (Default) |
>=35 Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | Temp_Timer | 35 to 32767 (Default) |
>=35 Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Humidity_Timer | 35 to 32767 (Default) |
>=35 Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 2 | VOC_Timer | 35 to 32767 (Default) |
>=35 Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 2 | Lux_Timer | 35 to 32767 (Default) |
>=35 Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 2 | dB_Timer | 35 to 32767 (Default) |
>=35 Report every n*1s interval | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | CO2_Delta_Level | 0 to 127 (Default) |
=0 Turn off report >=1 Report when change > n * 5ppm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Temp_Delta_Level | 0 to 127 (Default) |
=0 Turn off report >=1 Report when change > n*0.5℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Humidity_Delta_Level | 0 to 127 (Default) |
=0 Turn off report >=1 Report when change >n% | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
47 | 1 | Temp. unit | 0 to 1 (Default) |
=0 ℃ =1 ℉ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | VOC_Delta_Level | 0 to 127 (Default) |
=0 Turn off report >=1-127*5ppb Reportchange | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 1 | T_OffSet | -128 to 127 (Default) |
0 ~ 127: ((n-100)/10)=(-10~2.7)℃ -128 ~ -1: ((156+n)/10)=(2.8~15.5)℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 1 | RH_OffSet | 0 to 40 (Default) |
n-20=(-20~20)% | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
52 | 2 | CO2_OffSet | 0 to 1000 (Default) |
(n-500)=(-500~500)ppm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
53 | 1 | PM2.5_OffSet | -128 to 127 (Default) |
0 ~ 127: n-100=(-100~27)ug/m3 -128 ~ -1: 156+n=(28~155)ug/m3 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
54 | 2 | Lux_OffSet | 0 to 10000 (Default) |
n-5000=(-5000~5000)lux | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
55 | 1 | VOC_Correct | -128 to 127 (Default) |
0 ~ 127: n-100=(-100~27)ppb -128 ~ -1: 156+n=(28~155)ppb | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
56 | 1 | dB_Correct | 0 to 100 (Default) |
(n-50)=-50~50 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Lux_Delta_Level | 0 to 32767 (Default) |
=0 Turn off report >=1 Report when change > n*1 Lux | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | dB_Delta_Level | 0 to 127 (Default) |
=0 Turn off report >=1 Report when change > n*1dB | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | PIR_Delta_Level | 0 to 1 (Default) |
=0 Turn off report =1 Report change | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | SMOKE_Delta_Level | 0 to 1 (Default) |
=0 Turn off report =1 Report change | |