Z-Wave Products

There are over 4393 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: 9 in 1 MULTI-SENSOR (A8-9)

Z-Wave Certification Number: ZC10-19086697


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 PM25_Delta_Level 0 to 127
(Default)
=0 Turn off report >=1 Report when change > n * 1ug/m3

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Smoke_Timer 35 to 32767
(Default)
>=35 Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 PIR_Timer 35 to 32767
(Default)
>=35 Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 PM25_Timer 35 to 32767
(Default)
>=35Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 CO2_Timer 35 to 32767
(Default)
>=35 Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 Temp_Timer 35 to 32767
(Default)
>=35 Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Humidity_Timer 35 to 32767
(Default)
>=35 Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 VOC_Timer 35 to 32767
(Default)
>=35 Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 2 Lux_Timer 35 to 32767
(Default)
>=35 Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 2 dB_Timer 35 to 32767
(Default)
>=35 Report every n*1s interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 CO2_Delta_Level 0 to 127
(Default)
=0 Turn off report >=1 Report when change > n * 5ppm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Temp_Delta_Level 0 to 127
(Default)
=0 Turn off report >=1 Report when change > n*0.5℃

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Humidity_Delta_Level 0 to 127
(Default)
=0 Turn off report >=1 Report when change >n%

Parameter Number

Parameter Size

Parameter Name

Parameter Values

47 1 Temp. unit 0 to 1
(Default)
=0 ℃ =1 ℉

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 VOC_Delta_Level 0 to 127
(Default)
=0 Turn off report >=1-127*5ppb Reportchange

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 1 T_OffSet -128 to 127
(Default)
0 ~ 127: ((n-100)/10)=(-10~2.7)℃ -128 ~ -1: ((156+n)/10)=(2.8~15.5)℃

Parameter Number

Parameter Size

Parameter Name

Parameter Values

51 1 RH_OffSet 0 to 40
(Default)
n-20=(-20~20)%

Parameter Number

Parameter Size

Parameter Name

Parameter Values

52 2 CO2_OffSet 0 to 1000
(Default)
(n-500)=(-500~500)ppm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

53 1 PM2.5_OffSet -128 to 127
(Default)
0 ~ 127: n-100=(-100~27)ug/m3 -128 ~ -1: 156+n=(28~155)ug/m3

Parameter Number

Parameter Size

Parameter Name

Parameter Values

54 2 Lux_OffSet 0 to 10000
(Default)
n-5000=(-5000~5000)lux

Parameter Number

Parameter Size

Parameter Name

Parameter Values

55 1 VOC_Correct -128 to 127
(Default)
0 ~ 127: n-100=(-100~27)ppb -128 ~ -1: 156+n=(28~155)ppb

Parameter Number

Parameter Size

Parameter Name

Parameter Values

56 1 dB_Correct 0 to 100
(Default)
(n-50)=-50~50

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Lux_Delta_Level 0 to 32767
(Default)
=0 Turn off report >=1 Report when change > n*1 Lux

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 dB_Delta_Level 0 to 127
(Default)
=0 Turn off report >=1 Report when change > n*1dB

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 PIR_Delta_Level 0 to 1
(Default)
=0 Turn off report =1 Report change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 SMOKE_Delta_Level 0 to 1
(Default)
=0 Turn off report =1 Report change