Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | User Temperature Calibration | -250 to 250 (Default) |
Step-size = 10 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Temperature Limit - Cool Max | 60 to 95 (Default) |
Increment by 1F. The actual allowable range is dependent on the heat set point limit | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Temperature Limit - Cool Min | 50 to 75 (Default) |
Increment by 1F. The actual allowable range is dependent on the heat set point limit | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Temperature Minimum Setpoint Deadband | 100 to 250 (Default) |
Step-size = 10 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | Ambient Temperature Change Stepsize | 50 (Default) |
0.5F | |
100 | 1.0F | ||||
150 | 1.5F | ||||
200 | 2.0F | ||||
250 | 2.5F | ||||
300 | 3.0F | ||||
350 | 3.5F | ||||
400 | 4.0F | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Regular Ambient Temperature Reporting Interval | 1 to 24 (Default) |
1-24 hours | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Regular Operating State Reporting Interval | 1 to 24 (Default) |
1-24 hours | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Command Echo Enable | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Temperature Unit (C/F) | 0 | Celsius | |
1 (Default) |
Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Available Control mode | 0 (Default) |
Heat and Cool, Auto | |
1 | Heat Only | ||||
2 | Cool Only | ||||
3 | Heat and Cool, no Auto | ||||
4 | reserved | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | System Type | 0 (Default) |
Furnace Gas | |
1 | Furnace Electric | ||||
2 | Heat Pump | ||||
3 | Boiler no fan | ||||
4 | reserved | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Reversal valve Type in Heat Pump | 0 (Default) |
O-valve | |
1 | B-valve | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Temperature Limit - Heat Max | 60 to 90 (Default) |
Increment by 1F | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Temperature Limit - Heat Min | 45 to 60 (Default) |
Increment by 1F | |