TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO Wall Plug (FGWPx-102)

Z-Wave Certification Number: ZC10-19076603


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Always On function 0
(Default)
function inactive
  1 function activated

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 High priority power report 1 to 99
(Default)
power change in percent
  100 reports are disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Standard power report 1 to 99
(Default)
power change in percent
  100 reports are disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Power reporting interval 5 to 600
(Default)
in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Energy reporting threshold 0 energy reports inactive
  1 to 500
(Default)
(0.01-5kWh, step 0.01kWh) - threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 Power and energy periodic reports 0 periodic reports inactive
  5 to 32400
(Default)
in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Measuring energy consumed by the Wall Plug itself 0
(Default)
function inactive
  1 function activated

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Remember device status after a power failure 0 device remains switched off
  1
(Default)
device restores the state from before the power failure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Control of „On/Off (Button)” association group (2) devices 0
(Default)
control as the Wall Plug
  1 control opposite to the Wall Plug

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 2 DOWN value - „On/Off (Power)” association group (3) 0 to 24900
(Default)
(0.0-2490.0W, step 0.1W)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 2 UP value - „On/Off (Power)” association group (3) 100 to 25000
(Default)
10.0-2500.0W, step 0.1W)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 The response after exceeding defined power values 1 turn the associated devices ON, once the power drops below DOWN value (parameter 21)
  2 turn the associated devices OFF, once the power drops below DOWN value (parameter 21)
  3 turn the associated devices ON, once the power rises above UP value (parameter 22)
  4 turn the associated devices OFF, once the power rises above UP value (parameter 22)
  5 combination of 1 and 4. Turn the associated devices ON, once the power drops below DOWN value (parameter 21). Turn the associated devices OFF, once the power rises above UP value (parameter 22).
  6
(Default)
combination of 2 and 3. Turn the associated devices OFF, once the power drops below DOWN value (parameter 21). Turn the associated devices ON, once the power rises above UP value (parameter 22).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 2 SWITCH ON value - „On/Off” association groups 0 turning off associated devices
  1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 2 Overload safety switch 0
(Default)
function inactive
  10 to 30000 (1.0-3000.0W, step 0.1W) - power threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Active alarms 1 general alarm
  2 smoke alarm
  4 CO alarm
  8 CO2 alarm
  16 high temperature alarm
  32 flood alarm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 1 Response to alarm frames 0
(Default)
no reaction
  1 turn connected device on
  2 turn connected device off
  5 to 50 (0.5-50.0s, step 0.1s) - cyclically change device state with set period

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 2 Alarm state duration 1 to 32400
(Default)
in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 2 Power load for violet colour 1000 to 30000
(Default)
100.0-3000.0W, step 0.1W

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 LED ring colour when controlled device is on 0 illumination turned off completely
  1
(Default)
colour changes continuously depending on active power
  2 colour changes in steps depending on active power
  3 white
  4 red
  5 green
  6 blue
  7 yellow
  8 cyan
  9 magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 LED ring illumination colour when controlled device is off 0
(Default)
illumination turned off completely
  1 LED ring is illuminated with a colour corresponding to the last measured power, before the controlled device was turned off
  3 white
  4 red
  5 green
  6 blue
  7 yellow
  8 cyan
  9 magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 1 LED ring illumination colour at the Z-Wave network alarm detection 0 illumination turned off completely
  1 no change in colour. LED ring colour is determined by settings of parameters 41 or 42
  2
(Default)
LED ring flashes red/blue/white
  3 white
  4 red
  5 green
  6 blue
  7 yellow
  8 cyan
  9 magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 1 Associations in Z-Wave network security mode 0 none of the groups sent as secure
  1 2nd group sent as secure
  2 3rd group sent as secure
  3
(Default)
2nd and 3rd group sent as secure