There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Alarm cancellation delay | 0 to 3600 (Default) |
in seconds, each 1s | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | Temperature measurement interval | 1 to 65535 (Default) |
in seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Temperature measurement hysteresis | 1 to 1000 (Default) |
each 0.01°C | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Acoustic and visual signals On / Off in case of flooding | 0 | acoustic and visual alarms inactive | |
1 | acoustic alarm inactive, visual alarm active | ||||
2 | acoustic alarm active, visual alarm inactive | ||||
3 (Default) |
acoustic and visual alarms active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 2 | Low temperature alarm threshold | -10000 to 10000 (Default) |
each 0.01°C | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 2 | High temperature alarm threshold | -10000 to 10000 (Default) |
each 0.01°C | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 4 | Low temperature alarm indicator colour | 0 to 16777215 (Default) |
Red 16711680; Green 65280; Blue 255; Yellow 16776960; Turquoise 65535; Orange 16750848; White 16777215; Indicator turned off 0 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 4 | High temperature alarm indicator colour | 0 to 16777215 (Default) |
Red 16711680; Green 65280; Blue 255; Yellow 16776960; Turquoise 65535; Orange 16750848; White 16777215; Indicator turned off 0 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 1 | Temperature indication using LED visual indicator | 0 | visual indicator does not indicate the temperature | |
1 | visual indicator indicates the temperature (blink) every Temperature Measurement Interval (parameter 10, constant current and battery) and Wake Up Interval (battery mode) | ||||
2 (Default) |
visual indicator indicates the temperature continuously, only in constant power mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 2 | Requested dimming level / roller blind opening level when sending turn on / open command to 2nd association group devices | 1 to 99 | requested level | |
255 (Default) |
turn a device on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
73 | 2 | Temperature measurement compensation | -10000 to 10000 (Default) |
°C | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
74 | 1 | Alarm frame sent to 1st and 4th Association Group activation | 0 | tamper alarms inactive | |
1 | button tamper alarm active | ||||
2 (Default) |
movement tamper alarm active | ||||
3 | button and movement tampers alarm active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
75 | 4 | Alarms signalization duration | 0 (Default) |
alarms active indefinitely | |
1 to 65535 | time in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
76 | 4 | Alarm signalization reactivation period | 0 (Default) |
alarm reactivation inactive | |
1 to 65535 | time in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
77 | 1 | Flood sensor functionality turned off | 0 (Default) |
Default flood sensor operation (flood detection, reactions) | |
1 | Built-in flood sensor TURNED OFF (does not change its state in the main controller, does not send alarm notifications nor turn on/off commands to 2nd/3rd association groups with flood state changes. Always visible in the main controller as turned off) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
78 | 1 | Associations in Z-Wave network security mode | 0 | acoustic and visual alarms inactive | |
0 | none of the groups sent as secure | ||||
1 | 2nd group, Control, sent as secure | ||||
1 | acoustic alarm inactive, visual alarm active | ||||
2 | acoustic alarm active, visual alarm inactive | ||||
2 | 3rd group, Alarm, sent as secure | ||||
3 | acoustic and visual alarms active | ||||
4 | 4th group, Tamper, sent as secure | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Deactivate turning off devices in 2nd association group & alarm cancellation in 3rd group | 0 | alarm (flooding) cancellation inactive | |
1 (Default) |
alarm (flooding) cancellation active | ||||