Z-Wave Products

There are over 4393 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO Flood Sensor (FGFS-101)

Z-Wave Certification Number: ZC10-19076586


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 Alarm cancellation delay 0 to 3600
(Default)
in seconds, each 1s

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 Temperature measurement interval 1 to 65535
(Default)
in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Temperature measurement hysteresis 1 to 1000
(Default)
each 0.01°C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Acoustic and visual signals On / Off in case of flooding 0 acoustic and visual alarms inactive
  1 acoustic alarm inactive, visual alarm active
  2 acoustic alarm active, visual alarm inactive
  3
(Default)
acoustic and visual alarms active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 2 Low temperature alarm threshold -10000 to 10000
(Default)
each 0.01°C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

51 2 High temperature alarm threshold -10000 to 10000
(Default)
each 0.01°C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 4 Low temperature alarm indicator colour 0 to 16777215
(Default)
Red 16711680; Green 65280; Blue 255; Yellow 16776960; Turquoise 65535; Orange 16750848; White 16777215; Indicator turned off 0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 4 High temperature alarm indicator colour 0 to 16777215
(Default)
Red 16711680; Green 65280; Blue 255; Yellow 16776960; Turquoise 65535; Orange 16750848; White 16777215; Indicator turned off 0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

63 1 Temperature indication using LED visual indicator 0 visual indicator does not indicate the temperature
  1 visual indicator indicates the temperature (blink) every Temperature Measurement Interval (parameter 10, constant current and battery) and Wake Up Interval (battery mode)
  2
(Default)
visual indicator indicates the temperature continuously, only in constant power mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 2 Requested dimming level / roller blind opening level when sending turn on / open command to 2nd association group devices 1 to 99 requested level
  255
(Default)
turn a device on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

73 2 Temperature measurement compensation -10000 to 10000
(Default)
°C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

74 1 Alarm frame sent to 1st and 4th Association Group activation 0 tamper alarms inactive
  1 button tamper alarm active
  2
(Default)
movement tamper alarm active
  3 button and movement tampers alarm active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

75 4 Alarms signalization duration 0
(Default)
alarms active indefinitely
  1 to 65535 time in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

76 4 Alarm signalization reactivation period 0
(Default)
alarm reactivation inactive
  1 to 65535 time in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

77 1 Flood sensor functionality turned off 0
(Default)
Default flood sensor operation (flood detection, reactions)
  1 Built-in flood sensor TURNED OFF (does not change its state in the main controller, does not send alarm notifications nor turn on/off commands to 2nd/3rd association groups with flood state changes. Always visible in the main controller as turned off)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

78 1 Associations in Z-Wave network security mode 0 acoustic and visual alarms inactive
  0 none of the groups sent as secure
  1 2nd group, Control, sent as secure
  1 acoustic alarm inactive, visual alarm active
  2 acoustic alarm active, visual alarm inactive
  2 3rd group, Alarm, sent as secure
  3 acoustic and visual alarms active
  4 4th group, Tamper, sent as secure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Deactivate turning off devices in 2nd association group & alarm cancellation in 3rd group 0 alarm (flooding) cancellation inactive
  1
(Default)
alarm (flooding) cancellation active