Z-Wave Products

There are over 4407 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: CO Sensor (FGCD-001)

Z-Wave Certification Number: ZC10-19076622


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Commands sent to 2nd association group (CO Alarm) 1 BASIC ON
  2 BASIC OFF
  3
(Default)
BASIC ON & BASIC OFF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Value of BASIC ON command sent to 2nd association group 0 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Value of BASIC OFF command sent to 2nd association group 0 to 99
(Default)
forcing level of associated devices
  255 setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Commands sent to 4th association group (CO Level) 1 BASIC ON
  2 BASIC OFF
  3
(Default)
BASIC ON & BASIC OFF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 CO level required for sending BASIC ON command to 4th association group 20 to 400
(Default)
CO concentration level in ppm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Time required for sending BASIC ON command to 4th association group 0
(Default)
immediate sending of BASIC ON command
  1 to 2880 (30s - 24h, in 30s steps)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 Value of BASIC ON command sent to 4th association group 0 to 99 1-99 - forcing level of associated devices
  255
(Default)
255 - setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 2 CO Level required for sending BASIC OFF command to 4th association group 10 to 400
(Default)
CO concentration level in ppm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 2 Value of BASIC OFF command sent to 4th association group 0 to 99
(Default)
forcing level of associated devices
  255 setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Z-Wave notifications 0
(Default)
both actions disabled
  1 tampering (opened casing)
  2 exceeding the temperature
  3 both actions enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 2 Temperature reporting time interval 0
(Default)
no periodical reports
  10 to 1440 (5min - 24h, in 30s steps)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Temperature reporting hysteresis 1 to 20
(Default)
0.5°C - 10°C, each 0.5°C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Threshold of exceeding the temperature 1 to 85
(Default)
1°C - 85°C, each 1°C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 CO meter activation 0 disabled
  1
(Default)
enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 CO level reporting hysteresis 2 to 6
(Default)
10 ppm - 30 ppm, each 5 ppm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 2 Threshold of CO meter activation 10 to 255
(Default)
ppm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 LED diode indications 0
(Default)
all actions disabled
  1 tampering (opened casing)
  2 exceeding the temperature
  4 lack of Z-Wave range

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Acoustic signals 0
(Default)
all actions disabled
  1 tampering (opened casing)
  2 exceeding the temperature
  4 lack of Z-Wave range

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Associations in Z-Wave network security mode 1 2nd group sent as secure
  2 3rd group sent as secure
  4 4th group sent as secure
  8 5th group sent as secure
  16 6th group sent as secure
  32 7th group sent as secure