There are over 4407 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Commands sent to 2nd association group (CO Alarm) | 1 | BASIC ON | |
2 | BASIC OFF | ||||
3 (Default) |
BASIC ON & BASIC OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Value of BASIC ON command sent to 2nd association group | 0 to 99 | forcing level of associated devices | |
255 (Default) |
setting associated devices to the last remembered state or turning them on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Value of BASIC OFF command sent to 2nd association group | 0 to 99 (Default) |
forcing level of associated devices | |
255 | setting associated devices to the last remembered state or turning them on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Commands sent to 4th association group (CO Level) | 1 | BASIC ON | |
2 | BASIC OFF | ||||
3 (Default) |
BASIC ON & BASIC OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | CO level required for sending BASIC ON command to 4th association group | 20 to 400 (Default) |
CO concentration level in ppm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Time required for sending BASIC ON command to 4th association group | 0 (Default) |
immediate sending of BASIC ON command | |
1 to 2880 | (30s - 24h, in 30s steps) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 2 | Value of BASIC ON command sent to 4th association group | 0 to 99 | 1-99 - forcing level of associated devices | |
255 (Default) |
255 - setting associated devices to the last remembered state or turning them on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 2 | CO Level required for sending BASIC OFF command to 4th association group | 10 to 400 (Default) |
CO concentration level in ppm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 2 | Value of BASIC OFF command sent to 4th association group | 0 to 99 (Default) |
forcing level of associated devices | |
255 | setting associated devices to the last remembered state or turning them on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Z-Wave notifications | 0 (Default) |
both actions disabled | |
1 | tampering (opened casing) | ||||
2 | exceeding the temperature | ||||
3 | both actions enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 2 | Temperature reporting time interval | 0 (Default) |
no periodical reports | |
10 to 1440 | (5min - 24h, in 30s steps) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Temperature reporting hysteresis | 1 to 20 (Default) |
0.5°C - 10°C, each 0.5°C) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Threshold of exceeding the temperature | 1 to 85 (Default) |
1°C - 85°C, each 1°C) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | CO meter activation | 0 | disabled | |
1 (Default) |
enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
25 | 1 | CO level reporting hysteresis | 2 to 6 (Default) |
10 ppm - 30 ppm, each 5 ppm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
26 | 2 | Threshold of CO meter activation | 10 to 255 (Default) |
ppm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | LED diode indications | 0 (Default) |
all actions disabled | |
1 | tampering (opened casing) | ||||
2 | exceeding the temperature | ||||
4 | lack of Z-Wave range | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Acoustic signals | 0 (Default) |
all actions disabled | |
1 | tampering (opened casing) | ||||
2 | exceeding the temperature | ||||
4 | lack of Z-Wave range | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Associations in Z-Wave network security mode | 1 | 2nd group sent as secure | |
2 | 3rd group sent as secure | ||||
4 | 4th group sent as secure | ||||
8 | 5th group sent as secure | ||||
16 | 6th group sent as secure | ||||
32 | 7th group sent as secure | ||||