There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Dimmer 2 (FGD-212)

Z-Wave Certification Number: ZC10-19076645


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Minimum brightness level 1 to 98
(Default)
percentage level of brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Timer functionality (auto - off) 0
(Default)
Function disabled
  1 to 32767 time to turn off measured in seconds (1s-9.1h)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 ALL ON/ALL OFF function 0 ALL ON not active, ALL OFF not active
  1 ALL ON not active, ALL OFF active
  2 ALL ON active, ALL OFF not active
  255
(Default)
ALL ON active, ALL OFF active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Force auto-calibration 0
(Default)
readout
  1 force auto-calibration of the load without FIBARO Bypass 2
  2 force auto-calibration of the load with FIBARO Bypass 2

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Auto-calibration status 0
(Default)
calibration procedure not performed or Dimmer 2 operates on manual settings
  1 Dimmer 2 operates on auto-calibration settings

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Burnt out bulb detection 0 function disabled
  1 to 99
(Default)
percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection 0 detection of a burnt out bulb disabled
  1 to 255
(Default)
delay time in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Forced switch on brightness level 0
(Default)
function disabled
  1 to 99 percentage level of brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Maximum brightness level 2 to 99
(Default)
percentage level of brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Switch type 0
(Default)
momentary switch
  1 toggle switch
  2 roller blind switch - two switches operate the Dimmer 2 (S1 to brighten, S2 to dim)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 The value sent to associated devices on single click 0
(Default)
0xFF value is sent, which will set associated devices to their last saved state
  1 current Dimmer 2 state is sent, which will synchronize brightness level of associated devices (other dimmers for example)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Assign bistable key status to the device status 0
(Default)
Device changes status on key status change.
  1 Device status is synchronized with key status.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Double click option 0 double click disabled;
  1
(Default)
double click enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Command frames sent in 2-nd and 3-rd association groups (S1 associations) 0
(Default)
all actions send to association groups;
  1 do not send when switching on the Dimmer (single click);
  2 do not send when switching off the Dimmer (single click);
  4 do not send when changing dimming level (holding and releasing);
  8 do not send on double click;
  16 send 0xFF value on double click.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 Command frames sent in 4-th and 5-th association groups (S2 associations) 0
(Default)
all actions send to association groups;
  1 do not send when switching on the Dimmer (single click);
  2 do not send when switching off the Dimmer (single click);
  4 do not send when changing dimming level (holding and releasing);
  8 do not send on double click;
  16 send 0xFF value on double click

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 1 The function of 3-way switch 0
(Default)
3-way switch function for S2 disabled;
  1 3-way switch function for S2 disabled;

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Associations in Z-Wave network security mode 0 all groups (II-V) sent as non-secure
  1 to 2 group sent as secure
  2 to 3 group sent as secure
  4 group sent as secure
  8 to 5 group sent as secure
  15
(Default)
groups (II-V) sent as secure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

28 1 Scene activation functionality 0
(Default)
functionality deactivated;
  1 functionality activated.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

29 1 Switch functionality of S1 and S2 0
(Default)
standard mode;
  1 operates as S2, S2 operates as S1.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Incandescence level of dimmable compact fluorescent lamps 1 to 99
(Default)
percentage level of brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Load control mode 0 forced leading edge control;
  1 forced trailing edge control;
  2
(Default)
control mode selected automatically (based on auto-calibration).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 1 Load control mode recognized during auto-calibration 0
(Default)
leading edge;
  1 trailing edge.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 1 On/Off mode 0 on/off mode disabled (dimming is possible);
  1 on/off mode enabled (dimming is not possible
  2
(Default)
mode selected automatically

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 1 Dimmability of the load 0
(Default)
Load recognized as dimmable;
  1 Load recognized as non-dimmable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 1 Soft-Start functionality 0 no soft-start;
  1
(Default)
short soft-start (0.1s)
  2 long soft-start (0.5s)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 1 Auto-calibration after power on 0 No auto-calibration of the load after power on
  1
(Default)
Auto-calibration performed after first power on
  2 Auto-calibration performed after each power on
  3 Auto-calibration performed after first power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb), if parameter 37 is set to 1 also after alarms: SURGE (Dimmer 2 output overvoltage) and OVERCURRENT (Dimmer 2 output overcurrent)
  4 Auto-calibration performed after each power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb), if parameter 37 is set to 1 also after alarms: SURGE (Dimmer 2 output overvoltage) and OVERCURRENT (Dimmer 2 output overcurrent)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

37 1 Behaviour of the Dimmer after overload or surge. 0 device permanently disabled until re-enabling by command or external switch
  1
(Default)
three atempts to turn on the load

Parameter Number

Parameter Size

Parameter Name

Parameter Values

38 2 Brightness level correction for flickering loads 0 automatic correction disabled
  1 to 254 duration of correction in seconds
  255
(Default)
automatic correction always enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

39 2 Power limit - OVERLOAD 0 functionality disabled
  1 to 350
(Default)
1W-350W

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 2 Incandescence time of dimmable compact fluorescent lamps 0 to 255
(Default)
0s - 25.5s

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Response to General Purpose Alarm 0 No reaction
  1 Turn on the load
  2 Turn off the load
  3
(Default)
Load blinking

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Response to Water Flooding Alarm 0 No reaction
  1 Turn on the load
  2
(Default)
Turn off the load
  3 Load blinking

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 Response to Smoke, CO or CO2 Alarm 0 No reaction
  1 Turn on the load;
  2 Turn off the load
  3
(Default)
Load blinking

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 1 Response to Temperature Alarm 0 No reaction
  1
(Default)
Turn on the load
  2 Turn off the load
  3 Load blinking

Parameter Number

Parameter Size

Parameter Name

Parameter Values

44 2 Time of alarm state 1 to 132767
(Default)
1-32767 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

45 1 OVERLOAD alarm report 0 No reaction
  1
(Default)
Send and alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

46 1 LOAD ERROR alarm report 0 No reaction
  1
(Default)
Send and alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

47 1 OVERCURRENT alarm report 0 No reaction
  1
(Default)
Send and alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

48 1 SURGE alarm report 0 No reaction
  1
(Default)
Send and alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

49 1 OVERHEAT and VOLTAGE DROP alarm report 0 No reaction
  1
(Default)
Send and alarm frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Automatic control - dimming step size 1 to 99
(Default)
dimming step percentage value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 1 Active power reports 0 power reports disabled
  1 to 100
(Default)
(1-100%) - power report threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

52 2 Periodic active power and energy reports 0 periodic reports disabled
  1 to 32767
(Default)
(1-32767 seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

53 2 Energy reports 0 energy reports disabled
  1 to 255
(Default)
(0,01 - 2,55 kWh) - report triggering threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

54 1 Self-measurement 0
(Default)
Self-measurement inactive
  1 Self-measurement active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

58 1 Method of calculating the active power 0
(Default)
measurement based on the standard algorithm
  1 approximation based on the calibration data
  2 approximation based on the control angle

Parameter Number

Parameter Size

Parameter Name

Parameter Values

59 2 Approximated power at the maximum brightness level 0 to 500
(Default)
(0-500W) - power consumed by the load at the maximum brightness level.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Automatic control - time of a dimming step 0 to 255
(Default)
(0-2.55s, in 10ms steps)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Manual control - dimming step size 1 to 99
(Default)
dimming step percentage value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Manual control - time of a dimming step 0 to 255
(Default)
(0-2.55s, in 10ms steps)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Saving the state of the device after a power failure 0 the Dimmer 2 does not save the state before a power failure, it returns to „off” position
  1
(Default)
the Dimmer 2 restores its state before power failure