There are over 4401 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | operation mode | 0 | 0-valve (always) off | |
1 | 1-user absent=not at home=holiday | ||||
2 (Default) |
2 = user present=at home | ||||
3 | 3 = valve (always) on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | micro leakage pressure drop abort | 0 to 32000 (Default) |
pressure drop in kPa | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | number of measurements | 1 to 99 (Default) |
how many in one time period | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | wait time until next measurement | 0 to 60 (Default) |
waiting time in minutes between two meassurements | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | reaction to micro leakage | 0 to 2 (Default) |
0=disable detection, 1=blink LED, 2= blink LED andshut off valve | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | macro leakage detected | 0 (Default) |
no leackage | |
1 | leackage detected | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | max flow rate if operation mode is 2 | 0 to 32000 (Default) |
flowrate in l/h | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 2 | max pressure drop if operation mode is 2 | 0 to 32000 (Default) |
pressure drop in kPa | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 2 | max continious liter if operation mode is 2 | 0 to 32000 (Default) |
liter | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 2 | max continious time if operation mode is 2 | 0 to 32000 (Default) |
time in minutes for water flow in present mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 2 | max flow rate if operation mode is 1 | 0 to 32000 (Default) |
max flow rate in absent mode liters/hour | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 2 | max pressure drop if operation mode is 1 | 0 to 32000 (Default) |
max pressure drop in absent mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 2 | max continious liter if operation mode is 1 | 0 to 32000 (Default) |
max. liter of water in absent mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
26 | 2 | max continious time if operation mode is 1 | 0 to 32000 (Default) |
max. time of water flow in absent mode in minutes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
28 | 1 | reaction to macro leakage | 0 to 2 (Default) |
0=disable detection, 1=blink LED, 2= blink LED and shut off valve | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | reaction to flooding sensor | 0 to 2 (Default) |
0=disable detection, 1=blink LED, 2= blink LED andshut off valve | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 2 | backup battery nominal voltage | 0 to 7 (Default) |
shows backup battery voltage | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
37 | 1 | time set correctly | 0 to 1 (Default) |
0=time not set 1=time set correctly | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
38 | 4 | total operating time | 0 to 2147483647 (Default) |
Read only: Counting total operation time internally | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
39 | 4 | operating time since last power on | 0 to 2147483647 (Default) |
Read only counting operation time since last power off | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | fixed schedule time hours | 0 to 23 (Default) |
hour of day | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | fixed schedule time minutes | 0 to 59 (Default) |
minute | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 2 | water temperature high threshold | 0 to 32000 (Default) |
1°C = 10; Recommended 25°C by international standards | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 2 | water temperature low threshold | 0 to 32000 (Default) |
1°C = 10; Water icing prevention | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
54 | 1 | error code | 0 to 37 (Default) |
showing different error codes. See website for error description | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | fixed schedule day | 1 to 127 (Default) |
1111111 in binary, | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 2 | automatic schedule time interval | 0 to 168 (Default) |
How many days | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | micro leakage mesuring time | 0 to 32000 (Default) |
seconds measuring time | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | micro leakage pressure drop | 0 to 32000 (Default) |
presssure drop in kPa | |