Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Z-Wave Plus thermostat (CT200-G1)

Z-Wave Certification Number: ZC10-19086714


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Temperature Reporting Threshold 0 to 4
(Default)
0x00 Disable Reporting 0x01 0.5 degrees Fahrenheit 0x02 1.0 degrees Fahrenheit (DEFAULT) 0x03 1.5 degrees Fahrenheit 0x04 2.0 degrees Fahrenheit

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 Temperature Reporting Filter 0 to 1
(Default)
Lower Bound Temperature Scale
  0 to 124
(Default)
Lower Bound Temperature Filter
  0 to 1
(Default)
Upper Bound Temperature Scale
  0 to 124
(Default)
Upper Bound Temperature Filter

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Fan Timer 0 to 60
(Default)
0x00 Always On (DEFAULT) 0x0F 15 minutes 0x1E 30 minutes 0x3C 60 minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Temperature Calibration -6 to 6
(Default)
If your controller accepts hex values the range is 0xFA to 0x06 and the value represents the temperature calibration offset applied to the measured value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Display Units 0 to 1
(Default)
0x00 Fahrenheit (DEFAULT) 0x01 Celsius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 4 HVAC Settings 0 to 255
(Default)
Cooling Type, Heating Type
  0 to 255
(Default)
Heating Fuel, Heat/Aux Stages
  0 to 255
(Default)
A Terminal, Heat Pump Stages
  0 to 255
(Default)
O/B Terminal, Cooling Stages

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Utility Lock 0 to 3
(Default)
0x00 Disabled lock (DEFAULT) 0x01 n/a 0x02 n/a 0x03 Enabled lock

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Thermostat Power Source 1 to 2 0x01 C-Wire 0x02 Batteries

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Humidity Reporting Threshold 0 to 3
(Default)
0x00 Disabled Reporting 0x01 3% Relative Humidity 0x02 5% Relative Humidity (DEFAULT) 0x03 10% Relative Humidity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Auxiliary Heat 0 to 1
(Default)
0x00 Disabled auxiliary heat (DEFAULT) 0x01 Enabled auxiliary heat

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Thermostat Swing 0 to 8
(Default)
0x00 not supported 0x01 0.5 degrees Fahrenheit 0x02 1.0 degrees Fahrenheit (DEFAULT) 0x03 1.5 degrees Fahrenheit 0x04 2.0 degrees Fahrenheit 0x05 2.5 degrees Fahrenheit 0x06 3.0 degrees Fahrenheit 0x07 3.5 degrees Fahrenheit 0x08 4.0 degrees Fahrenheit

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Thermostat Differential 0 to 1
(Default)
Differential Mode
  4 to 12 Differential Temperature

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Thermostat Recovery Mode 0 to 1 0x01 Fast Mode 0x02 Economy Mode (DEFAULT)