There are over 4407 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: S2 Dimmer Switch (ZW313)

Z-Wave Certification Number: ZC10-19086727


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Locally Button function 0
(Default)
Up Button ON,Down Button OFF.
  1 Up Button OFF,Down Button ON
  2 Up Button ON/OFF,Down Button ON/OFF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Multilevel minimum value can be set 0 The minimum luminance value of the dimming

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Multilevel maxmum value can be set 0 to 99
(Default)
The maxmum luminance value of the dimming

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 quickly press UPPER paddle 2 times 0
(Default)
Turn ON to 99
  1 turn on to the value relate

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Double Tap Behavior 0
(Default)
enable double tap to full brightness
  1 disable double tap to full brightness, single tap to last brightness level
  2 disable double tap to full brightness, single tap always to full brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Enable or Disable local control 0 disable
  1
(Default)
enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Status LED Configuration 0
(Default)
Output ON,Led OFF.
  1 OutputOFF,Led ON.
  2 Always OFF
  3 Always ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Enable Auto Turn-OFF Timer 0
(Default)
Disabled
  1 Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 4 Auto Turn-Off Timer 1 to 65535
(Default)
Auto Turn-Off Timer

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Enable Auto Turn-ON Timer 0
(Default)
Disabled
  1 Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 4 Auto Turn-ON Timer 1 to 65535
(Default)
Auto Turn-ON Timer

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Association Setting Parameter 0 None
  1 Local
  2 3-way
  3 3-way&Local
  4 Z-Wave hub
  5 Z-Wave hub&Local
  6 Z-Wave hub&3-way
  7 Z-Wave hub&Local&3-way
  8 Timer
  9 Timer&Local
  10 Timer&3-way
  11 Timer&3-way&Local
  12 Timer&Z-Wave hub
  13 Timer&Z-Wave hub&Local
  14 Timer&Z-Wave hub&3-way
  15
(Default)
ALL

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Restores state after power failure 0 Output OFF
  1 Output ON
  2
(Default)
The state before a power outage.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Dimmer Speed Parameter 1 to 99
(Default)
from 0x63 to 0x00 or from 0x00 to 0x63 need Value Second