There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Remember device status before the power failure | 0 (Default) |
device remains switched off | |
1 | device restores the state from before the power failure | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
150 | 1 | Inputs - LED colour control mode | 0 (Default) |
RGBW mode (every input controls output with the same number, IN1‑OUT1, IN2‑OUT2, IN3‑OUT3, IN4‑OUT4) | |
1 | HSB and White mode (inputs works in HSB color model, IN1‑H (Hue), IN2‑S (Saturation), IN3‑B (Brightness), IN4‑White (OUT4) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 2 | Local control - transition time | 0 | instantly | |
1 to 127 (Default) |
(1s-127s, 1s step) | ||||
128 to 254 | (1min-127min, 1min step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 2 | Remote control - transition time | 0 | instantly | |
1 to 127 (Default) |
(1s-127s, 1s step) | ||||
128 to 254 | (1min-127min, 1min step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
153 | 2 | Active reports | 1 | Root/EP1 Switch Color Report (RGBW) | |
2 | Root/EP1 Central Scene Report | ||||
4 | EP2 Switch Multilevel Report (Red) | ||||
8 | EP3 Switch Multilevel Report (Green) | ||||
16 | EP4 Switch Multilevel Report (Blue) | ||||
32 | EP5 Switch Multilevel Report (White) | ||||
64 | EP6 Sensor Multilevel Report (analog input 1) | ||||
128 | EP7 Sensor Multilevel Report (analog input 2) | ||||
256 | EP8 Sensor Multilevel Report (analog input 3) | ||||
512 | EP9 Sensor Multilevel Report (analog input 4) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
154 | 4 | ON frame value for single click | 0 to 99 (Default) |
value sent to devices | |
255 | value sent to devices | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
155 | 4 | OFF frame value for single click | 0 to 99 (Default) |
value sent to devices | |
255 | value sent to devices | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
156 | 4 | ON frame value for double click | 0 to 99 (Default) |
value sent to devices | |
255 | value sent to devices | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
157 | 1 | Start programmed sequence | 0 (Default) |
sequence inactive | |
1 to 5 | user-defined sequence | ||||
6 | Fireplace sequence | ||||
7 | Storm sequence | ||||
8 | Rainbow sequence | ||||
9 | Aurora sequence | ||||
10 | Police (red-white-blue) sequence | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Input 1 - operating mode | 0 | Analog input without internal pull-up (Sensor Multilevel) | |
1 | Analog input with internal pull-up (Sensor Multilevel) | ||||
2 (Default) |
Momentary switch (Central Scene) | ||||
3 | Toggle switch: switch state on every input change (Central Scene) | ||||
4 | Toggle switch: contact closed – ON, contact opened – OFF (Central Scene) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Input 2 - operating mode | 0 | Analog input without internal pull-up (Sensor Multilevel) | |
1 | Analog input with internal pull-up (Sensor Multilevel) | ||||
2 (Default) |
Momentary switch (Central Scene) | ||||
3 | Toggle switch: switch state on every input change (Central Scene) | ||||
4 | Toggle switch: contact closed – ON, contact opened – OFF (Central Scene) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Input 3 - operating mode | 0 | Analog input without internal pull-up (Sensor Multilevel) | |
1 | Analog input with internal pull-up (Sensor Multilevel) | ||||
2 (Default) |
Momentary switch (Central Scene) | ||||
3 | Toggle switch: switch state on every input change (Central Scene) | ||||
4 | Toggle switch: contact closed – ON, contact opened – OFF (Central Scene) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Input 4 - operating mode | 0 | Analog input without internal pull-up (Sensor Multilevel) | |
1 | Analog input with internal pull-up (Sensor Multilevel) | ||||
2 (Default) |
Momentary switch (Central Scene) | ||||
3 | Toggle switch: switch state on every input change (Central Scene) | ||||
4 | Toggle switch: contact closed – ON, contact opened – OFF (Central Scene) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 4 | Alarm configuration - 1st slot | 1 | [MSB] – Notification Type | |
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action: 0x00 – no reaction, 0x0X – turn off selected channel, 0x1X – turn on selected channel, 0x2X – blink selected channel, 0x3Y – activate alarm sequence | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 4 | Alarm configuration - 2nd slot | 1 | [MSB] – Notification Type | |
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action: 0x00 – no reaction, 0x0X – turn off selected channel, 0x1X – turn on selected channel, 0x2X – blink selected channel, 0x3Y – activate alarm sequence | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 4 | Alarm configuration - 3rd slot | 1 | [MSB] – Notification Type | |
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action: 0x00 – no reaction, 0x0X – turn off selected channel, 0x1X – turn on selected channel, 0x2X – blink selected channel, 0x3Y – activate alarm sequence | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 4 | Alarm configuration - 4th slot | 1 | [MSB] – Notification Type | |
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action: 0x00 – no reaction, 0x0X – turn off selected channel, 0x1X – turn on selected channel, 0x2X – blink selected channel, 0x3Y – activate alarm sequence | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
34 | 4 | Alarm configuration - 5th slot | 1 | [MSB] – Notification Type | |
2 | Notification Status | ||||
3 | Event/State Parameters | ||||
4 | [LSB] – action: 0x00 – no reaction, 0x0X – turn off selected channel, 0x1X – turn on selected channel, 0x2X – blink selected channel, 0x3Y – activate alarm sequence | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
35 | 2 | Duration of alarm signalization | 0 | infinite signalization | |
1 to 32400 (Default) |
(1s-9h, 1s step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Input 1 - sent scenes | 0 (Default) |
Key pressed 1 time | |
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Input 2 - sent scenes | 1 | Key pressed 1 time | |
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | Input 3 - sent scenes | 1 | Key pressed 1 time | |
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
43 | 1 | Input 4 - sent scenes | 1 | Key pressed 1 time | |
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 2 | Power reports - on change | 0 | reports are disabled | |
1 to 500 (Default) |
(1-500%) - change in power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 2 | Power reports - periodic | 0 | periodic reports are disabled | |
30 to 32400 (Default) |
(30-32400s) - report interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 2 | Analog inputs reports - on change | 0 | reporting on change disabled | |
1 to 100 (Default) |
(0.1-10V, 0.1V step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
64 | 2 | Analog inputs reports - periodic | 0 (Default) |
periodical reports disabled | |
30 to 32400 | (30-32400s, 1s step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Energy reports - on change | 0 | reports are disabled | |
1 to 500 (Default) |
(0.01 - 5 kWh) - change in energy | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Energy reports - periodic | 0 | periodic reports are disabled | |
30 to 32400 (Default) |
(30-32400s) - report interval | ||||