TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Battery report | 255 to 4200 (Default) |
255 to 4200 seconds in 255 second increments that the sensor should wait between sending unsolicited battery reports. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | dwell window | 1 to 9 (Default) |
1 to 9 minutes. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Pet Immunity | 0 to 2 (Default) |
0 to 2 sensitivity. 0: No pet immunity 1: 15kg (33lb) 2:25kg (55lb) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | walk test | 0 to 15 (Default) |
0: Normal operation 0xFF: Activate Walk Test for 15 minutes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 2 | Wakeup Notification | 0 to 3600 (Default) |
1 (must be divisible by sleep step time of configuration parameter 7) to 3600 (0x0E10) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Application Level Retries | 0 to 5 (Default) |
0 is no application level retries to 5 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | sleep between application level retries. | 1 to 6 (Default) |
1 to 60 seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Supervisory Report | 500 to 5000 (Default) |
500 to 5000 milliseconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Sleep step time | 1 to 255 | 1 to 255 seconds | |