There are over 4400 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Z-WAVE PLUS ON / OFF LIGHT SWITCH (ZEN21 VER 3.0)

Z-Wave Certification Number: ZC10-19096759


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Paddle Control 0 to 2
(Default)
0 – Upper paddle turns the light on, lower paddle turns the light off (default); 1 – Upper paddle turns the light off, lower paddle turns the light on; 2 – Any paddle will turn light on / off depending on the status.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Enable/Disable Paddle Control 0 to 1
(Default)
0 – local control disabled. 1 – local control enabled (default).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 LED Indicator Control 0
(Default)
LED indicator is on when switch is off, LED indicator is off when switch is on (default)
  1 LED indicator is on when switch is on, LED indicator is off when switch is off
  2 LED indicator is always OFF
  3 LED indicator is always ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Enable / Disable Auto Turn-Off Timer 0 to 1
(Default)
0 – timer disabled (default); 1 – timer enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 4 Set Auto Turn-Off Timer 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Enable / Disable Auto Turn-Off Timer 0 to 1
(Default)
0 – timer disabled (default); 1 – timer enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 4 Set Auto Turn-On Timer 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 On Off Status After Power Failure 0 0 – forced to OFF (regardless of state prior to power outage)
  1 forced to ON
  2
(Default)
remembers and restores on/off status a􀈇er power failure (default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Enable/Disable Scene Control 0 to 1
(Default)