There are over 4377 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Switch Type of External Switch 1 | 0 (Default) |
Unidentified mode when no identify is set, and indicate identify fails when in identify. | |
1 | 2-state switch mode | ||||
2 | 3 way switch mode | ||||
3 | Push Button mode | ||||
4 | Enter automatic identification mode(The blue led will fast blink) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
121 | 1 | Switch Type of External Switch 1 | 0 (Default) |
Unidentified mode when no identify is set, and indicate identify fails when in identify. | |
1 | 2-state switch mode | ||||
2 | 3 way switch mode | ||||
3 | Push Button mode | ||||
4 | Enter automatic identification mode(The blue led will fast blink) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Motor Behavior After Power ON | 0 (Default) |
Stay the same position before power off last time | |
1 | Moves to 99% | ||||
2 | Moves to 0% | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Determine motor run direction | 2 (Default) |
Set to change the motor direction | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
248 | 1 | Function Setting of External Switch S1&S2 | 1 (Default) |
Enable network function, inclusion/exclusion | |
2 | Enable reset to factory default function | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset Function | 0 (Default) |
Reset all configuration parameters to default settings | |
1431655765 | reset to factory default settings and removed from the z-wave network | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
34 | 2 | Set the Blade Turn Time | 10 to 32767 (Default) |
0.1 - 327.67seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
35 | 2 | Curtain Trip Time | 500 to 32767 (Default) |
5 - 327.67 seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
36 | 1 | Enter/Exit Calibration | 0 (Default) |
Set:Exit Calibration Report: Not in Calibration | |
1 | Set:Enter Shutter Mode Calibration Report: In Shutter Mode Calibration | ||||
2 | Set:Enter Venetian Mode Calibration Report: In Venetian Mode Calibration | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
37 | 1 | User confirmation for Calibration | 0 (Default) |
Go to next step of calibration | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
38 | 1 | Calibration Status Report | 0 (Default) |
Calibration Complete | |
1 | Calibration start, going to Reference Point A | ||||
2 | Reach Reference Point A, going to Reference Point B | ||||
3 | Reach Reference Point B, waiting for Blade turn Calibraion(Only for Venetian Mode) | ||||
4 | Going to Reference Point C(Only for Venetian Mode) | ||||
5 | Calibration terminated | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
39 | 1 | Cutain Mode Setting | 0 (Default) |
Shutter Mode | |
1 | Venetian Mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Repositioning | 1 (Default) |
Repositioning begins | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Repositioning Status Report | 0 (Default) |
Repositioning complete | |
1 | in repositioning | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | Calibration Lock | 0 | Disable calibration | |
1 (Default) |
Enable Action Button/ Command Calibration | ||||
2 | Enable Action Button/ Command/S1/S2 Calibration | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | Switch Status Report Selection | 0 | No Report | |
1 | Basic Report | ||||
2 (Default) |
Switch Multilevel Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
85 | 1 | Extern Button Mode Setting | 0 (Default) |
Extern Button 1 maps to Z-wave Button,Extern Button 2 opens or stops motor. | |
1 | Extern Button 1 maps to Z-wave Button,Extern Button 2 closes or stops motor. | ||||