There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 2 | Threshold of power report | 0 to 200 (Default) |
Available settings: 0 - 200 (0 - 200W) | |
0 | 0 - The function is disabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 1 | Percentage threshold of power report | 0 | The function is disabled. | |
0 to 100 (Default) |
Available settings: 0 - 100 (0 - 100%) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
171 | 4 | Power report frequency | 0 | The function is disabled. | |
3600 to 2678400 (Default) |
Available settings: 3600- 2678400 (3600 - 2678400s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
172 | 4 | Energy report frequency | 0 | The function is disabled. | |
3600 to 2678400 (Default) |
Available settings: 3600- 2678400 (3600 - 2678400s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
173 | 4 | Voltage report frequency | 0 (Default) |
The function is disabled. | |
3600 to 2678400 | Available settings: 3600- 2678400 (3600 - 2678400s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
174 | 4 | Electricity report frequency | 0 (Default) |
The function is disabled. | |
3600 to 2678400 | Available settings: 3600- 2678400 (3600 - 2678400s) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Overload protection | 0 | The function is disabled | |
1 (Default) |
The function is enabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Setting device status after power failure | 0 (Default) |
Smart Plug memorizes its state after a power failure. | |
1 | Smart Plug does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected. | ||||
2 | Smart Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Notification when Load status change | 0 | The function is disabled. | |
1 (Default) |
Send Basic report. | ||||
2 | Send Basic report only when Load condition is not changed by Z-WAVE Command. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
254 | 1 | Enable/disable the configuration command | 0 (Default) |
Unlock | |
1 | Lock | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Indicator modes | 0 (Default) |
The indicator light remains the same as the load on/off status. When the load is on, the light is on, and the off is off. | |
1 | Within 5 seconds after the operation load, the indicator light is consistent with the load on/off status, and then the indicator is off. | ||||