There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Plug (HKZW-SO13)

Z-Wave Certification Number: ZC10-19116791


Parameter Number

Parameter Size

Parameter Name

Parameter Values

151 2 Threshold of power report 0 to 200
(Default)
Available settings: 0 - 200 (0 - 200W)
  0 0 - The function is disabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

152 1 Percentage threshold of power report 0 The function is disabled.
  0 to 100
(Default)
Available settings: 0 - 100 (0 - 100%)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

171 4 Power report frequency 0 The function is disabled.
  3600 to 2678400
(Default)
Available settings: 3600- 2678400 (3600 - 2678400s)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

172 4 Energy report frequency 0 The function is disabled.
  3600 to 2678400
(Default)
Available settings: 3600- 2678400 (3600 - 2678400s)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

173 4 Voltage report frequency 0
(Default)
The function is disabled.
  3600 to 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

174 4 Electricity report frequency 0
(Default)
The function is disabled.
  3600 to 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Overload protection 0 The function is disabled
  1
(Default)
The function is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Setting device status after power failure 0
(Default)
Smart Plug memorizes its state after a power failure.
  1 Smart Plug does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected.
  2 Smart Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Notification when Load status change 0 The function is disabled.
  1
(Default)
Send Basic report.
  2 Send Basic report only when Load condition is not changed by Z-WAVE Command.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

254 1 Enable/disable the configuration command 0
(Default)
Unlock
  1 Lock

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Indicator modes 0
(Default)
The indicator light remains the same as the load on/off status. When the load is on, the light is on, and the off is off.
  1 Within 5 seconds after the operation load, the indicator light is consistent with the load on/off status, and then the indicator is off.