Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | On Off Status After Power Failure | 0 (Default) |
forced to OFF (regardless of state prior to power outage) | |
1 | remem-bers and restores on/off status after power failure | ||||
2 | forced to ON (regard-less of state prior to power outage) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
150 | 1 | RGBW / HSB Wall Switch Mode | 0 (Default) |
RGBW mode (default) | |
1 | HSB mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 2 | Physical Ramp Rate | 0 | instant on/off | |
1 to 127 (Default) |
seconds | ||||
128 to 254 | 1 - 127 minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 2 | Z-Wave Ramp Rate | 0 | instant on/off | |
1 to 127 (Default) |
seconds | ||||
128 to 254 | 1 - 127 minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
154 | 4 | Single Click ON Trigger for Associated Devices | 0 to 99 | custom brightness level | |
255 (Default) |
ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
155 | 4 | Single Click OFF Trigger for Associated Devices | 0 to 99 (Default) |
custom brightness level | |
255 | ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
156 | 4 | Double Click ON Trigger for Associated Devices | 0 to 99 (Default) |
custom brightness level | |
255 | ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
157 | 1 | Preset Programs | 0 (Default) |
preset programs disabled (default) | |
6 | fireplace | ||||
7 | storm | ||||
8 | rainbow | ||||
9 | polar lights | ||||
10 | police (strobing red, white, and blue) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Switch / Input Type for IN1 | 0 | analog sensor with no pull-up | |
1 | analog sensor with pull-up | ||||
2 (Default) |
momentary switch (default) | ||||
3 | toggle switch (state changes whenever the switch is toggled) | ||||
4 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Switch / Input Type for IN2 | 0 | analog sensor with no pull-up | |
1 | analog sensor with pull-up | ||||
2 (Default) |
momentary switch (default) | ||||
3 | toggle switch (state changes whenever the switch is toggled) | ||||
4 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Switch / Input Type for IN3 | 0 | analog sensor with no pull-up | |
1 | analog sensor with pull-up | ||||
2 (Default) |
momentary switch (default) | ||||
3 | toggle switch (state changes whenever the switch is toggled) | ||||
4 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Switch / Input Type for IN4 | 0 | analog sensor with no pull-up | |
1 | analog sensor with pull-up | ||||
2 (Default) |
momentary switch (default) | ||||
3 | toggle switch (state changes whenever the switch is toggled) | ||||
4 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Scene Control for IN1 | 0 | scene control disabled | |
1 | click / toggle the connected switch once to trigger a scene | ||||
2 | click / toggle the connected switch twice to trigger a scene | ||||
4 | click / toggle the connected switch 3 times to trigger a scene | ||||
8 | hold and release the connected momentary switch to trigger a scene | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Scene Control for IN2 | 0 | scene control disabled | |
1 | click / toggle the connected switch once to trigger a scene | ||||
2 | click / toggle the connected switch twice to trigger a scene | ||||
4 | click / toggle the connected switch 3 times to trigger a scene | ||||
8 | hold and release the connected momentary switch to trigger a scene | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | Scene Control for IN3 | 0 | scene control disabled | |
1 | click / toggle the connected switch once to trigger a scene | ||||
2 | click / toggle the connected switch twice to trigger a scene | ||||
4 | click / toggle the connected switch 3 times to trigger a scene | ||||
8 | hold and release the connected momentary switch to trigger a scene | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
43 | 1 | Scene Control for IN4 | 0 | scene control disabled | |
1 | click / toggle the connected switch once to trigger a scene | ||||
2 | click / toggle the connected switch twice to trigger a scene | ||||
4 | click / toggle the connected switch 3 times to trigger a scene | ||||
8 | hold and release the connected momentary switch to trigger a scene | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 2 | Power Report Frequency | 0 | disabled (it will not report power consumption based on the fre- quency setting) | |
30 to 32400 (Default) |
seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 2 | Analog Sensor Voltage Reporting / Trigger Threshold | 0 | disabled (it will not report voltage based on value change) | |
1 to 100 (Default) |
0.1 – 10 V | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
64 | 2 | Analog Sensor Report Frequency | 0 (Default) |
disabled (it will not report voltage based on the frequency setting) | |
30 to 32400 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Energy Report Threshold | 0 | disabled (it will not report energy use based on value change) | |
1 to 500 (Default) |
0.01 - 5 kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Energy Report Frequency | 0 | disabled (it will not report energy use based on the frequency setting) | |
30 to 32400 (Default) |
seconds | ||||