There are over 4158 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: RGBW DIMMER ZEN31 (ZEN31)

Z-Wave Certification Number: ZC10-19126818


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 On Off Status After Power Failure 0
(Default)
forced to OFF (regardless of state prior to power outage)
  1 remem-bers and restores on/off status after power failure
  2 forced to ON (regard-less of state prior to power outage)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

150 1 RGBW / HSB Wall Switch Mode 0
(Default)
RGBW mode (default)
  1 HSB mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

151 2 Physical Ramp Rate 0 instant on/off
  1 to 127
(Default)
seconds
  128 to 254 1 - 127 minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

152 2 Z-Wave Ramp Rate 0 instant on/off
  1 to 127
(Default)
seconds
  128 to 254 1 - 127 minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

154 4 Single Click ON Trigger for Associated Devices 0 to 99 custom brightness level
  255
(Default)
ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

155 4 Single Click OFF Trigger for Associated Devices 0 to 99
(Default)
custom brightness level
  255 ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

156 4 Double Click ON Trigger for Associated Devices 0 to 99
(Default)
custom brightness level
  255 ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

157 1 Preset Programs 0
(Default)
preset programs disabled (default)
  6 fireplace
  7 storm
  8 rainbow
  9 polar lights
  10 police (strobing red, white, and blue)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Switch / Input Type for IN1 0 analog sensor with no pull-up
  1 analog sensor with pull-up
  2
(Default)
momentary switch (default)
  3 toggle switch (state changes whenever the switch is toggled)
  4 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Switch / Input Type for IN2 0 analog sensor with no pull-up
  1 analog sensor with pull-up
  2
(Default)
momentary switch (default)
  3 toggle switch (state changes whenever the switch is toggled)
  4 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Switch / Input Type for IN3 0 analog sensor with no pull-up
  1 analog sensor with pull-up
  2
(Default)
momentary switch (default)
  3 toggle switch (state changes whenever the switch is toggled)
  4 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Switch / Input Type for IN4 0 analog sensor with no pull-up
  1 analog sensor with pull-up
  2
(Default)
momentary switch (default)
  3 toggle switch (state changes whenever the switch is toggled)
  4 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Scene Control for IN1 0 scene control disabled
  1 click / toggle the connected switch once to trigger a scene
  2 click / toggle the connected switch twice to trigger a scene
  4 click / toggle the connected switch 3 times to trigger a scene
  8 hold and release the connected momentary switch to trigger a scene

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Scene Control for IN2 0 scene control disabled
  1 click / toggle the connected switch once to trigger a scene
  2 click / toggle the connected switch twice to trigger a scene
  4 click / toggle the connected switch 3 times to trigger a scene
  8 hold and release the connected momentary switch to trigger a scene

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 Scene Control for IN3 0 scene control disabled
  1 click / toggle the connected switch once to trigger a scene
  2 click / toggle the connected switch twice to trigger a scene
  4 click / toggle the connected switch 3 times to trigger a scene
  8 hold and release the connected momentary switch to trigger a scene

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 1 Scene Control for IN4 0 scene control disabled
  1 click / toggle the connected switch once to trigger a scene
  2 click / toggle the connected switch twice to trigger a scene
  4 click / toggle the connected switch 3 times to trigger a scene
  8 hold and release the connected momentary switch to trigger a scene

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 2 Power Report Frequency 0 disabled (it will not report power consumption based on the fre- quency setting)
  30 to 32400
(Default)
seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

63 2 Analog Sensor Voltage Reporting / Trigger Threshold 0 disabled (it will not report voltage based on value change)
  1 to 100
(Default)
0.1 – 10 V

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 2 Analog Sensor Report Frequency 0
(Default)
disabled (it will not report voltage based on the frequency setting)
  30 to 32400 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 2 Energy Report Threshold 0 disabled (it will not report energy use based on value change)
  1 to 500
(Default)
0.01 - 5 kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Energy Report Frequency 0 disabled (it will not report energy use based on the frequency setting)
  30 to 32400
(Default)
seconds