Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: 4-in-1 Sensor (LZW60)

Z-Wave Certification Number: ZC10-20016857


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Low Battery Power Level Alarm 10 to 50
(Default)
Value at which the sensor reports low battery to the gateway 10 = 10%, 11 = 11%... 50 = 50%, etc

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 Temperature Reporting Interval 0 to 2678400
(Default)
"The interval between when temperature is reported to the gateway 0 = Off, 1 = 1 second, 2 = 2 seconds... 2678400 = 2678400 seconds (NOTE: the sensor reporting time will round to the nearest minute)"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 Humidity Reporting Interval 0 to 2678400
(Default)
"The interval between when humidity is reported to the gateway 0 = Off, 1 = 1 second, 2 = 2 seconds... 2678400 = 2678400 seconds (NOTE: the sensor reporting time will round to the nearest minute)"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 Luminance Reporting Interval 0 to 2678400
(Default)
"The interval between when luminance is reported to the gateway 0 = Off, 1 = 1 second, 2 = 2 seconds... 2678400 = 2678400 seconds (NOTE: the sensor reporting time will round to the nearest minute)"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

104 4 Battery Reporting Interval 0 to 2678400
(Default)
"The interval between when battery is reported to the gateway 0 = Off, 1 = 1 second, 2 = 2 seconds... 2678400 = 2678400 seconds (NOTE: the sensor reporting time will round to the nearest minute)"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 2 Temperature Threshold 1 to 500
(Default)
"Set the threshold of the temperature for your sensor 1 = 0.1 degree Celcius (I know… wish it was Farenheit), 500 = 50 degrees Celcius "

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 1 Humidity Threshold 1 to 32
(Default)
"Set the threshold of the humidity for your sensor 1 = 1%, 2 = 2%... 32 = 32%"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 2 Luminance Threshold 1 to 32767
(Default)
"Set the threshold of the luminance for your sensor 1 = 1 unit lux, 2 = 2 unit lux… 65528 = 65528 unit lux"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

114 1 Battery Threshold 0 to 100
(Default)
"Set the threshold of the battery for your sensor 1 = 1%, 2 = 2%... 100 = 100%"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 PIR Sensitivity 0 to 10
(Default)
Change the sensitivity of the PIR (Motion) Sensor 0 = Off, 1 = Low Sensitivity, 10 = High Sensitivity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 PIR Trigger Time (Time Between PIR Readings) 5 to 15300
(Default)
"The amount of seconds between motion detection (ie: the interval) 5 = 5 seconds, 6 = 6 seconds... 15300 = 15300 seconds"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Basic Set Command Send after PIR Trigger 0 to 1
(Default)
"Should Basic Set Command be sent after PIR is triggered: 0 = No, 1 = Yes"

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 PIR Trigger Correspondence Action 0 to 1
(Default)
"Ability to reverse the Basic Set behavior for devices associated in group 2. 0 = Turn the associated device ON when motion is tripped, and OFF when motion stops. 1 = Turn the associated device OFF when motion is tripped, and ON when motion stops."