Z-Wave Products

There are over 4401 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Implant (FGBS-222)

Z-Wave Certification Number: ZC10-20036875


Parameter Number

Parameter Size

Parameter Name

Parameter Values

150 1 Input 1 - sensitivity 1 to 100
(Default)
(10ms-1000ms, 10ms step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

151 1 Input 2 - sensitivity 1 to 100
(Default)
(10ms-1000ms, 10ms step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

152 2 Input 1 - delay of alarm cancellation 0
(Default)
no delay
  1 to 3600 (in seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

153 2 Input 2 - delay of alarm cancellation 0
(Default)
no delay
  1 to 3600 (in seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

154 1 Output 1 - logic of operation 0
(Default)
contacts normally open / closed when active
  1 contacts normally closed / open when active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

155 1 Output 2 - logic of operation 0
(Default)
contacts normally open / closed when active
  1 contacts normally closed / open when active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

156 2 Output 1 - auto off 0
(Default)
auto off disabled
  1 to 27000 (0.1s-45min, 0.1s step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

157 2 Output 2 - auto off 0
(Default)
auto off disabled
  1 to 27000 (0.1s-45min, 0.1s step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Input 1 - operating mode 0 Normally closed alarm input (Notification)
  1 Normally open alarm input (Notification)
  2
(Default)
Monostable button (Central Scene)
  3 Bistable button (Central Scene)
  4 Analog input without internal pull-up (Sensor Multilevel)
  5 Analog input with internal pullup (Sensor Multilevel)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Input 2 - operating mode 0 Normally closed alarm input (Notification CC)
  1 Normally open alarm input (Notification CC)
  2
(Default)
Monostable button (Central Scene CC)
  3 Bistable button (Central Scene CC)
  4 Analog input without internal pull-up (Sensor Multilevel CC)
  5 Analog input with internal pullup (Sensor Multilevel CC)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Inputs orientation 0
(Default)
default (IN1 - 1st input, IN2 - 2nd input)
  1 reversed (IN1 - 2nd input, IN2 - 1st input)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 Outputs orientation 0
(Default)
default (OUT1 - 1st output, OUT2 - 2nd output)
  1 reversed (OUT1 - 2nd output, OUT2 - 1st output)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Input 1 - sent scenes 1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key hold down and key released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Input 2 - sent scenes 1 Key pressed 1 time
  2 Key pressed 2 time
  4 Key pressed 3 time
  8 Key hold down and key released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

47 2 Input 1 - value sent to 2nd association group when activated 0 to 255
(Default)
Value send to devices

Parameter Number

Parameter Size

Parameter Name

Parameter Values

49 2 Input 1 - value sent to 2nd association group when deactivated 0 to 255
(Default)
value send to devices

Parameter Number

Parameter Size

Parameter Name

Parameter Values

52 2 Input 2 - value sent to 3rd association group when activated 0 to 255
(Default)
value send to devices

Parameter Number

Parameter Size

Parameter Name

Parameter Values

54 2 Input 2 - value sent to 3rd association group when deactivated 0 to 255
(Default)
value send to devices

Parameter Number

Parameter Size

Parameter Name

Parameter Values

63 1 Analog inputs - minimal change to report 0 reporting on change disabled
  1 to 100
(Default)
(0.1-10V, 0.1V step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 2 Analog inputs - periodical reports 0
(Default)
periodical reports disabled
  60 to 32400 (60s-9h)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 2 Internal temperature sensor - minimal change to report 0 reporting on change disabled
  1 to 255
(Default)
(0.1-25.5°C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Internal temperature sensor - periodical reports 0
(Default)
periodical reports disabled
  60 to 32400 (60s-9h)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

67 2 External sensors - minimal change to report 0 reporting on change disabled
  1 to 255
(Default)
(0.1-25.5 units, 0.1)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

68 2 External sensors - periodical reports 0
(Default)
periodical reports disabled
  60 to 32400 (60s-9h)