There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
150 | 1 | Input 1 - sensitivity | 1 to 100 (Default) |
(10ms-1000ms, 10ms step) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
151 | 1 | Input 2 - sensitivity | 1 to 100 (Default) |
(10ms-1000ms, 10ms step) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
152 | 2 | Input 1 - delay of alarm cancellation | 0 (Default) |
no delay | |
1 to 3600 | (in seconds) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
153 | 2 | Input 2 - delay of alarm cancellation | 0 (Default) |
no delay | |
1 to 3600 | (in seconds) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
154 | 1 | Output 1 - logic of operation | 0 (Default) |
contacts normally open / closed when active | |
1 | contacts normally closed / open when active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
155 | 1 | Output 2 - logic of operation | 0 (Default) |
contacts normally open / closed when active | |
1 | contacts normally closed / open when active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
156 | 2 | Output 1 - auto off | 0 (Default) |
auto off disabled | |
1 to 27000 | (0.1s-45min, 0.1s step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
157 | 2 | Output 2 - auto off | 0 (Default) |
auto off disabled | |
1 to 27000 | (0.1s-45min, 0.1s step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Input 1 - operating mode | 0 | Normally closed alarm input (Notification) | |
1 | Normally open alarm input (Notification) | ||||
2 (Default) |
Monostable button (Central Scene) | ||||
3 | Bistable button (Central Scene) | ||||
4 | Analog input without internal pull-up (Sensor Multilevel) | ||||
5 | Analog input with internal pullup (Sensor Multilevel) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Input 2 - operating mode | 0 | Normally closed alarm input (Notification CC) | |
1 | Normally open alarm input (Notification CC) | ||||
2 (Default) |
Monostable button (Central Scene CC) | ||||
3 | Bistable button (Central Scene CC) | ||||
4 | Analog input without internal pull-up (Sensor Multilevel CC) | ||||
5 | Analog input with internal pullup (Sensor Multilevel CC) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Inputs orientation | 0 (Default) |
default (IN1 - 1st input, IN2 - 2nd input) | |
1 | reversed (IN1 - 2nd input, IN2 - 1st input) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
25 | 1 | Outputs orientation | 0 (Default) |
default (OUT1 - 1st output, OUT2 - 2nd output) | |
1 | reversed (OUT1 - 2nd output, OUT2 - 1st output) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Input 1 - sent scenes | 1 | Key pressed 1 time | |
2 | Key pressed 2 times | ||||
4 | Key pressed 3 times | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Input 2 - sent scenes | 1 | Key pressed 1 time | |
2 | Key pressed 2 time | ||||
4 | Key pressed 3 time | ||||
8 | Key hold down and key released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
47 | 2 | Input 1 - value sent to 2nd association group when activated | 0 to 255 (Default) |
Value send to devices | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
49 | 2 | Input 1 - value sent to 2nd association group when deactivated | 0 to 255 (Default) |
value send to devices | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
52 | 2 | Input 2 - value sent to 3rd association group when activated | 0 to 255 (Default) |
value send to devices | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
54 | 2 | Input 2 - value sent to 3rd association group when deactivated | 0 to 255 (Default) |
value send to devices | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 1 | Analog inputs - minimal change to report | 0 | reporting on change disabled | |
1 to 100 (Default) |
(0.1-10V, 0.1V step) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
64 | 2 | Analog inputs - periodical reports | 0 (Default) |
periodical reports disabled | |
60 to 32400 | (60s-9h) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Internal temperature sensor - minimal change to report | 0 | reporting on change disabled | |
1 to 255 (Default) |
(0.1-25.5°C) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Internal temperature sensor - periodical reports | 0 (Default) |
periodical reports disabled | |
60 to 32400 | (60s-9h) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
67 | 2 | External sensors - minimal change to report | 0 | reporting on change disabled | |
1 to 255 (Default) |
(0.1-25.5 units, 0.1) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
68 | 2 | External sensors - periodical reports | 0 (Default) |
periodical reports disabled | |
60 to 32400 | (60s-9h) | ||||