Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | NTC RESISTANCE | Floor Sensor Resistance (kΩ) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 1 | 100 | No | No | No |
Value |
Description |
||||
1 | Floor Sensor Resistance in kiloOhms (kΩ) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | TIME FORMAT | Time format | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | 24 hour format | ||||
1 (2) | 12 hour (AM/PM) format | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | WEEKDAY | Week day. This parameter allows manually adjustment of the day of the week in case if the thermostat is not connected to any Z-Wave gateway or Parameter 09 (auto-correction) is selected as 0. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 7 | No | No | No |
Bit (Value) |
Description |
||||
1 (2) | Monday | ||||
2 (4) | Tuesday | ||||
3 (8) | Wednesday | ||||
4 (16) | Thursday | ||||
5 (32) | Friday | ||||
6 (64) | Saturday | ||||
7 (128) | Sunday | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | HOUR | Time hour | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 23 | No | No | No |
Value |
Description |
||||
0 | This Parameter allows manual adjustment of Time in hours (24 hours). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | MINUTE | Time minutes | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 59 | No | No | No |
Value |
Description |
||||
0 | This Parameter allows manual adjustment of the Time in minutes (60 minutes)) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 2 | AIR TEMP MIN | Air Temperature Minimum in °C, value X 10, e.g. 22.5°C=225 The AIR TEMP MIN value cannot be higher than AIR TEMP MAX value –10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
210 | 40 | 360 | No | No | No |
Value |
Description |
||||
40 | This Parameter is the room temperature low limit – reading the internal temperature sensor. This only comes into effect if FA or PA are selected as the source sensor in Parameter 04. The factory default value is 21°C (69°F). Note: The AtL value cannot be higher than AtH value –1°C. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 2 | AIR TEMP MAX | Air Temperature Maximum in °C, x10 The AIR TEMP MAX value cannot be lower than AIR TEMP MIN value +10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
270 | 50 | 370 | No | No | No |
Value |
Description |
||||
50 | This Parameter is the room temperature high limit – reading the internal temperature sensor. This only comes into effect if FA or PA are selected as the source sensor in Parameter 4. The factory default value is 27°C (80°F). Note: The AtH value cannot be lower than AtL value +1°C. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 2 | FLOOR TEMP MIN | Floor Temperature Minimum in °C, x10 The FLOOR TEMP MIN value cannot be higher than FLOOR TEMP MAX value –10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
180 | 40 | 360 | No | No | No |
Value |
Description |
||||
40 | This Parameter is the floor temperature low limit – reading the external NTC temperature sensor. It only comes into effect if AF or PF are selected as the source sensor. The factory default value is 18°C or 64°F. Note: The FtL value cannot be higher than FtH value –1°C. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 2 | FLOOR TEMP MAX | Floor Temperature Maximum in °C, x10 The FLOOR TEMP MAX value cannot be lower than FLOOR TEMP MIN value +10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
320 | 50 | 370 | No | No | No |
Value |
Description |
||||
50 | This Parameter is the floor temperature high limit – reading the external NTC temperature sensor. It only comes into effect if AF or PF are selected as the source sensor. The factory default value is 32°C (89°F). Note: The FtH value cannot be lower than FtL value +1°C. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | DEGREE MODE | Degree mode (C/F) Floor and air temperature, as well as Set Point and all Parameters will be indicated in the chosen mode. Factory default value is degrees Celsius (0). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Celsius | ||||
1 (2) | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 1 | AIR TEMP CORRECTION | Air Temperature Calibration in °C, x10. This Parameter defines the offset value for room air temperature. If the internal air temperature sensor is not correctly calibrated, then manual calibration can be made by adjusting the values up to ±9.5°C or ±17°F (this value will be added or subtracted from the internal air temperature sensor reading). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -95 | 95 | No | No | No |
From |
To |
Description |
|||
-95 | 95 | This value will be added or subtracted from the internal air temperature sensor reading. | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | S1 INPUT MODE | S1 input mode | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | No action will be taken (the input state is ignored by the Thermostat logic). | ||||
1 (2) | Thermostat will be switched to the operating mode selected in Parameter 3 if the output was short-circuited. The Heating Thermostat will go back to previous mode as soon as the input is open. | ||||
2 (4) | Thermostat will be switched to the operating mode selected in Parameter 3 if the output was short-circuited, but it will not undertake any action if the input is open again. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | FLOOR TEMP CORRECTION | Floor Temperature Calibration in °C, x10. This Parameter defines the offset value for floor temperature. If the external floor temperature sensor is not calibrated properly, then manual calibration can be made by adjusting the values up to ±9.5°C or ±17°F (this value will be added or subtracted from the floor temperature sensor reading). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -95 | 95 | No | No | No |
From |
To |
Description |
|||
-95 | 95 | This value will be added or subtracted from the floor temperature sensor reading. | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
21 | 1 | TEMP HYSTERESYS | Temperature Hysteresis in °C, x10. The HE-HT01 will stabilize the temperature with selected hysteresis. For example, if the SET POINT is set for 25°C and HYSTERESIS is set for 0.5°C the HE-HT01 will change the state to IDLE if the temperature reaches 25.0°C, but it will change the state to HEATING if the temperature becomes lower than 24.5°C. The hysteresis can be changed from 0.2°C to 10.0°C range in Celsius mode, and from 0.3°F to 18.0°F in Fahrenheit mode. The factory default value is 0.5°C (0.9°F). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 2 | 100 | No | No | No |
Value |
Description |
||||
2 | Hysteresis value for temperature control. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
22 | 1 | AUTO BRIGHTNESS | Display auto-brightness control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Manual Control: display inactive state brightness will be set to the level defined by Parameter 23. | ||||
1 (2) | Automatic Brightness Control. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
23 | 1 | MANUAL BRIGHTNESS | Display manual brightness level. The Display Brightness Level Parameter will take effect when Parameter 22 is set to Manual Control (value = 0). Note: The environment illumination is displayed in the TIME position and also can be checked at any time via a Z-Wave gateway. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 1 | 15 | No | No | No |
Value |
Description |
||||
1 | The LCD brightness may be adjusted from 1 (lowest brightness) to 15 (highest brightest). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
24 | 1 | TOUCH THRESHOLD | Touch buttons sensitivity. 5 = Highly sensitive. 50 = Lowest sensitivity. Note: Setting the sensitivity too high can lead to false touch detection. We recommend not changing this Parameter unless there is a need to do so. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
15 | 5 | 50 | No | No | No |
Value |
Description |
||||
5 | Threshold to be adjusted from level 5 (very sensitive) to 50 (minimal sensitivity). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
25 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
26 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
27 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
28 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
29 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | S1 INPUT ACTION | Mode number for S1 input action | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 1 | 7 | No | No | No |
Bit (Value) |
Description |
||||
1 (2) | COM mode | ||||
2 (4) | TIME mode | ||||
3 (8) | DRY mode | ||||
4 (16) | ECO mode | ||||
5 (32) | VAC mode | ||||
6 (64) | MAN mode with IDLE (Off) state | ||||
7 (128) | MAN mode with HEATING (On) state | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
30 | 1 | BASIC SET MODE | Mode to switch to on Basic Set Action command receive. This Parameter defines which Operating Mode the HE-HT01 reverts to if the Basic Set command is received. If the Basic Set command value is 0 (OFF state) the HE-HT01 will go to Manual (MAN) mode and switch off the heating element (IDLE mode). If the Basic Set command is 1 or higher (ON state) the HE-HT01 will change the Mode to the corresponding selected Parameter value. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 6 | No | No | No |
Bit (Value) |
Description |
||||
1 (2) | COM mode | ||||
2 (4) | TIME mode | ||||
3 (8) | DRY mode | ||||
4 (16) | ECO mode | ||||
5 (32) | VAC mode | ||||
6 (64) | MAN Mode with HEATING state | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
31 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
32 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
33 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
34 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
35 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
36 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
37 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
38 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
39 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | SOURCE TYPE | Source Sensor: 1=A, 2=AF, 3=F, 4=FA, 5=P, 6=PA, 7=PF | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 1 | 7 | No | No | No |
Bit (Value) |
Description |
||||
1 (2) | A – Air sensor. Regulation (heating control) is based on the SET POINT applied to the internal room air temperature sensor. | ||||
2 (4) | AF – Air sensor + Floor sensor. Regulation is based on SET POINT applied to the internal room temperature sensor but also controlled by the floor temperature sensor ensuring that the floor temperature remains within the set limits. The lower floor temperature limit is specified in Parameter 16 (FtL) and the high temperature limit in parameter 17 (FtH). | ||||
3 (8) | F – Floor sensor. Regulation is based on the SET POINT applied to the external floor temperature sensor. | ||||
4 (16) | FA – Floor sensor + Air sensor. Regulation is based on SET POINT applied to the external floor sensor but is also controlled by the internal air temperature sensor ensuring that the room temperature remains within the set limits. The lower air temperature limit is specified in Parameter 14 (AtL) and the higher temperature limit in Parameter 15 (AtH). | ||||
5 (32) | P – Power regulator. Regulation is based on the time settings for heating which will be ON during the time in Parameter 05 (POn) and then OFF during the time in Parameter 06 (POf). This cycle will be repeated constantly. | ||||
6 (64) | PA – Power regulator + Air sensor. Regulation is based on the time set by Parameters 05 and 06 but also controlled by the internal air temperature sensor ensuring that the room temperature remains within the set limits. The air temperature limits are specified in Parameters 14 and 15. | ||||
7 (128) | PF – Power regulator + Floor sensor. Regulation is based on the time set by Parameters 05 and 06 but also controlled by the floor temperature sensor ensuring that the floor temperature remains within set limits. The floor temperature limits are specified in Parameters 16 and 17. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
1 (2) | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
41 | 1 | SENSORS REPORT TIME | Sensors consecutive reporting interval, minutes. When the device is connected to the Z-Wave gateway (controller), it periodically sends to the gateway reports from its room & floor temperature, humidity and light sensors even if there are not changes in the values. This Parameter defines the interval between consecutive reports. The value can be adjusted from 1 min to 120 min. Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value. In order not to increase traffic on your network, it is not recommended to reduce the value of this parameter. We recommend to reduce the value of this parameter only in case of poor connection, when reports from the device does not always reach the gateway. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 1 | 120 | No | No | No |
Value |
Description |
||||
1 | The value can be adjusted from 1 to 120 minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
42 | 1 | CONSUMPTION REPORT TIME | Consumption meter consecutive reporting interval, minutes. This Parameter defines the interval between consecutive reports of real time and cumulative energy consumption data to the gateway. The value can be adjusted from 1 min to 120 min. The factory default value is 10 min. Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value. In order not to increase traffic on your network, it is not recommended to reduce the value of this parameter. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 1 | 120 | No | No | No |
Value |
Description |
||||
1 | The value can be adjusted from 1 to 120 minutes. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
43 | 1 | TEMPERATURE THRESHOLD | Temperature difference to send to controller, value x10. This parameter determines the change in temperature level (in °C) resulting in temperature sensors report being sent to the gateway. The value of this parameter should be x10, e.g. for 0.4°C use value 40. From 0.5°C to 10°C can be selected. Use the value 0 if there is a need to stop sending the reports. The factory default value is 0.5°C (5). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Stop sending the reports | ||||
5 | Temperature level (in °C) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
44 | 1 | HUMIDITY THRESHOLD | Humidity difference to send to controller, %. This parameter determines the change in humidity level in % resulting in humidity sensors report being sent to the gateway. From 2% to 25% can be selected. Use the value 0 if there is a need to stop sending the reports. The factory default value is 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 25 | No | No | No |
Value |
Description |
||||
0 | Stop sending the reports | ||||
2 | Humidity level in % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
45 | 1 | LIGHT THRESHOLD | Light sensor values difference to send to controller, %. This parameter determines the change in temperature level resulting in temperature sensors report being sent to the gateway. From 10% to 99% can be selected. Use the value 0 if there is a need to stop sending the reports. The factory default value is 50. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | Stop sending the reports | ||||
10 | Temperature level change in % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
46 | 2 | MORNING START TIME | Morning start time. Format: HHMM. e.g.08:00 should be sent as 0800 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
600 | 0 | 2359 | No | No | No |
Value |
Description |
||||
0 | Morning start time. Format: HHMM (from 00:00 to 23:59) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
47 | 2 | DAY START TIME | Day start time. Format: HHMM. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
900 | 0 | 2359 | No | No | No |
Value |
Description |
||||
0 | Day start time. Format: HHMM (from 00:00 to 23:59) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
48 | 2 | EVENING START TIME | Evening start time. Format: HHMM. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1800 | 0 | 2359 | No | No | No |
Value |
Description |
||||
0 | Evening start time. Format: HHMM (from 00:00 to 23:59) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
49 | 2 | NIGHT START TIME | Night start time. Format: HHMM. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2300 | 0 | 2359 | No | No | No |
Value |
Description |
||||
0 | Night start time. Format: HHMM (from 00:00 to 23:59) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 2 | POWER REGULATION ON TIME | Power Regulation ON time, min | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
30 | 10 | 240 | No | No | No |
Value |
Description |
||||
10 | This Parameter defines floor HEATING time in minutes when Power Regulator (P, PA or PF) is selected as the source sensor in Parameter 04. Time values can be changed in the range: 10 to 240 minutes. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
50 | 2 | MONDAY MORNING TEMP | Monday Morning temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Monday Morning temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
51 | 2 | MONDAY DAYTIME TEMP | Monday Day temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
200 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Monday Day temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
52 | 2 | MONDAY EVENING TEMP | Monday Evening temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Monday Evening temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
53 | 2 | MONDAY NIGHT TEMP | Monday Night temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
180 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Monday Night temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
54 | 2 | TUESDAY MORNING TEMP | Tuesday Morning temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Tuesday Morning temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
55 | 2 | TUESDAY DAYTIME TEMP | Tuesday Day temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
200 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Tuesday Day temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
56 | 2 | TUESDAY EVENING TEMP | Tuesday Evening temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Tuesday Evening temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
57 | 2 | TUESDAY NIGHT TEMP | Tuesday Night temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
180 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Tuesday Night temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
58 | 2 | WEDNESDAY MORNING TEMP | Wednesday Morning temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Wednesday Morning temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
59 | 2 | WEDNESDAY DAYTIME TEMP | Wednesday Day temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
200 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Wednesday Day temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 2 | POWER REGULATION OFF TIME | Power Regulation OFF time, min | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
30 | 10 | 240 | No | No | No |
Value |
Description |
||||
10 | This Parameter defines floor IDLE time in minutes when Power Regulator (P, PA or PF) is selected as the source sensor in Parameter 04. Time can be changed in the range: 10 to 240 minutes. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
60 | 2 | WEDNESDAY EVENING TEMP | Wednesday Evening temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Wednesday Evening temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
61 | 2 | WEDNESDAY NIGHT TEMP | Wednesday Night temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
180 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Wednesday Night temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
62 | 2 | THURSDAY MORNING TEMP | Thursday Morning temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Thursday Morning temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
63 | 2 | THURSDAY DAYTIME TEMP | Thursday Day temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
200 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Thursday Day temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
64 | 2 | THURSDAY EVENING TEMP | Thursday Evening temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Thursday Evening temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
65 | 2 | THURSDAY NIGHT TEMP | Thursday Night temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
180 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Thursday Night temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
66 | 2 | FRIDAY MORNING TEMP | Friday Morning temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Friday Morning temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
67 | 2 | FRIDAY DAYTIME TEMP | Friday Day temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
200 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Friday Day temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
68 | 2 | FRIDAY EVENING TEMP | Friday Evening temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Friday Evening temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
69 | 2 | FRIDAY NIGHT TEMP | Friday Night temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
180 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Friday Night temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | DRY TIME | Dry Time, min | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
30 | 5 | 90 | No | No | No |
Value |
Description |
||||
5 | This Parameter specifies how long in minutes the Heating Thermostat will be in HEATING mode when the DRY mode is selected. After this time the HE-HT01 will enter the mode specified in Parameter 8. The time range is 5 to 90 minutes. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
70 | 2 | SATURDAY MORNING TEMP | Saturday Morning temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Saturday Morning temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
71 | 2 | SATURDAY DAYTIME TEMP | Saturday Day temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
200 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Saturday Day temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
72 | 2 | SATURDAY EVENING TEMP | Saturday Evening temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Saturday Evening temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
73 | 2 | SATURDAY NIGHT TEMP | Saturday Night temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
180 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Saturday Night temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
74 | 2 | SUNDAY MORNING TEMP | Sunday Morning temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Sunday Morning temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
75 | 2 | SUNDAY DAYTIME TEMP | Sunday Day temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
200 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Sunday Day temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
76 | 2 | SUNDAY EVENING TEMP | Sunday Evening temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Sunday Evening temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
77 | 2 | SUNDAY NIGHT TEMP | Sunday Night temperature, valueX10 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
180 | 40 | 370 | No | No | No |
Value |
Description |
||||
40 | Sunday Night temperature value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | DRY SWITCH MODE | Mode to switch after Dry mode operation completion | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 6 | No | No | No |
Bit (Value) |
Description |
||||
1 (2) | COM mode | ||||
2 (4) | TIME mode | ||||
4 (16) | ECO mode | ||||
5 (32) | VAC mode | ||||
6 (64) | MAN mode mode with IDLE state | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | TIME CORRECTION | Time correction by controller | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Switch off auto-correction | ||||
1 (2) | If thermostat is connected to a Z-Wave gateway, the time and day will be periodically polled and corrected from the gateway | ||||