There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Heating Thermostat (HE-HT01)

Z-Wave Certification Number: ZC12-19120023


Parameter Number

Parameter Size

Parameter Name

Description

1 1 NTC RESISTANCE Floor Sensor Resistance (kΩ)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 1 100 No No No

Value

 

Description

1   Floor Sensor Resistance in kiloOhms (kΩ)

Parameter Number

Parameter Size

Parameter Name

Description

10 1 TIME FORMAT Time format

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   24 hour format
1 (2)   12 hour (AM/PM) format

Parameter Number

Parameter Size

Parameter Name

Description

11 1 WEEKDAY Week day. This parameter allows manually adjustment of the day of the week in case if the thermostat is not connected to any Z-Wave gateway or Parameter 09 (auto-correction) is selected as 0.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 7 No No No

Bit (Value)

 

Description

1 (2)   Monday
2 (4)   Tuesday
3 (8)   Wednesday
4 (16)   Thursday
5 (32)   Friday
6 (64)   Saturday
7 (128)   Sunday

Parameter Number

Parameter Size

Parameter Name

Description

12 1 HOUR Time hour

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 23 No No No

Value

 

Description

0   This Parameter allows manual adjustment of Time in hours (24 hours).

Parameter Number

Parameter Size

Parameter Name

Description

13 1 MINUTE Time minutes

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 59 No No No

Value

 

Description

0   This Parameter allows manual adjustment of the Time in minutes (60 minutes))

Parameter Number

Parameter Size

Parameter Name

Description

14 2 AIR TEMP MIN Air Temperature Minimum in °C, value X 10, e.g. 22.5°C=225 The AIR TEMP MIN value cannot be higher than AIR TEMP MAX value –10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

210 40 360 No No No

Value

 

Description

40   This Parameter is the room temperature low limit – reading the internal temperature sensor. This only comes into effect if FA or PA are selected as the source sensor in Parameter 04. The factory default value is 21°C (69°F). Note: The AtL value cannot be higher than AtH value –1°C.

Parameter Number

Parameter Size

Parameter Name

Description

15 2 AIR TEMP MAX Air Temperature Maximum in °C, x10 The AIR TEMP MAX value cannot be lower than AIR TEMP MIN value +10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

270 50 370 No No No

Value

 

Description

50   This Parameter is the room temperature high limit – reading the internal temperature sensor. This only comes into effect if FA or PA are selected as the source sensor in Parameter 4. The factory default value is 27°C (80°F). Note: The AtH value cannot be lower than AtL value +1°C.

Parameter Number

Parameter Size

Parameter Name

Description

16 2 FLOOR TEMP MIN Floor Temperature Minimum in °C, x10 The FLOOR TEMP MIN value cannot be higher than FLOOR TEMP MAX value –10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

180 40 360 No No No

Value

 

Description

40   This Parameter is the floor temperature low limit – reading the external NTC temperature sensor. It only comes into effect if AF or PF are selected as the source sensor. The factory default value is 18°C or 64°F. Note: The FtL value cannot be higher than FtH value –1°C.

Parameter Number

Parameter Size

Parameter Name

Description

17 2 FLOOR TEMP MAX Floor Temperature Maximum in °C, x10 The FLOOR TEMP MAX value cannot be lower than FLOOR TEMP MIN value +10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

320 50 370 No No No

Value

 

Description

50   This Parameter is the floor temperature high limit – reading the external NTC temperature sensor. It only comes into effect if AF or PF are selected as the source sensor. The factory default value is 32°C (89°F). Note: The FtH value cannot be lower than FtL value +1°C.

Parameter Number

Parameter Size

Parameter Name

Description

18 1 DEGREE MODE Degree mode (C/F) Floor and air temperature, as well as Set Point and all Parameters will be indicated in the chosen mode. Factory default value is degrees Celsius (0).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Celsius
1 (2)   Fahrenheit

Parameter Number

Parameter Size

Parameter Name

Description

19 1 AIR TEMP CORRECTION Air Temperature Calibration in °C, x10. This Parameter defines the offset value for room air temperature. If the internal air temperature sensor is not correctly calibrated, then manual calibration can be made by adjusting the values up to ±9.5°C or ±17°F (this value will be added or subtracted from the internal air temperature sensor reading).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 -95 95 No No No

From

 

To

Description

-95   95 This value will be added or subtracted from the internal air temperature sensor reading.

Parameter Number

Parameter Size

Parameter Name

Description

2 1 S1 INPUT MODE S1 input mode

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   No action will be taken (the input state is ignored by the Thermostat logic).
1 (2)   Thermostat will be switched to the operating mode selected in Parameter 3 if the output was short-circuited. The Heating Thermostat will go back to previous mode as soon as the input is open.
2 (4)   Thermostat will be switched to the operating mode selected in Parameter 3 if the output was short-circuited, but it will not undertake any action if the input is open again.

Parameter Number

Parameter Size

Parameter Name

Description

20 1 FLOOR TEMP CORRECTION Floor Temperature Calibration in °C, x10. This Parameter defines the offset value for floor temperature. If the external floor temperature sensor is not calibrated properly, then manual calibration can be made by adjusting the values up to ±9.5°C or ±17°F (this value will be added or subtracted from the floor temperature sensor reading).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 -95 95 No No No

From

 

To

Description

-95   95 This value will be added or subtracted from the floor temperature sensor reading.

Parameter Number

Parameter Size

Parameter Name

Description

21 1 TEMP HYSTERESYS Temperature Hysteresis in °C, x10. The HE-HT01 will stabilize the temperature with selected hysteresis. For example, if the SET POINT is set for 25°C and HYSTERESIS is set for 0.5°C the HE-HT01 will change the state to IDLE if the temperature reaches 25.0°C, but it will change the state to HEATING if the temperature becomes lower than 24.5°C. The hysteresis can be changed from 0.2°C to 10.0°C range in Celsius mode, and from 0.3°F to 18.0°F in Fahrenheit mode. The factory default value is 0.5°C (0.9°F).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 2 100 No No No

Value

 

Description

2   Hysteresis value for temperature control.

Parameter Number

Parameter Size

Parameter Name

Description

22 1 AUTO BRIGHTNESS Display auto-brightness control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Manual Control: display inactive state brightness will be set to the level defined by Parameter 23.
1 (2)   Automatic Brightness Control.

Parameter Number

Parameter Size

Parameter Name

Description

23 1 MANUAL BRIGHTNESS Display manual brightness level. The Display Brightness Level Parameter will take effect when Parameter 22 is set to Manual Control (value = 0). Note: The environment illumination is displayed in the TIME position and also can be checked at any time via a Z-Wave gateway.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 1 15 No No No

Value

 

Description

1   The LCD brightness may be adjusted from 1 (lowest brightness) to 15 (highest brightest).

Parameter Number

Parameter Size

Parameter Name

Description

24 1 TOUCH THRESHOLD Touch buttons sensitivity. 5 = Highly sensitive. 50 = Lowest sensitivity. Note: Setting the sensitivity too high can lead to false touch detection. We recommend not changing this Parameter unless there is a need to do so.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

15 5 50 No No No

Value

 

Description

5   Threshold to be adjusted from level 5 (very sensitive) to 50 (minimal sensitivity).

Parameter Number

Parameter Size

Parameter Name

Description

25 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

26 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

27 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

28 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

29 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 S1 INPUT ACTION Mode number for S1 input action

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 1 7 No No No

Bit (Value)

 

Description

1 (2)   COM mode
2 (4)   TIME mode
3 (8)   DRY mode
4 (16)   ECO mode
5 (32)   VAC mode
6 (64)   MAN mode with IDLE (Off) state
7 (128)   MAN mode with HEATING (On) state

Parameter Number

Parameter Size

Parameter Name

Description

30 1 BASIC SET MODE Mode to switch to on Basic Set Action command receive. This Parameter defines which Operating Mode the HE-HT01 reverts to if the Basic Set command is received. If the Basic Set command value is 0 (OFF state) the HE-HT01 will go to Manual (MAN) mode and switch off the heating element (IDLE mode). If the Basic Set command is 1 or higher (ON state) the HE-HT01 will change the Mode to the corresponding selected Parameter value.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 6 No No No

Bit (Value)

 

Description

1 (2)   COM mode
2 (4)   TIME mode
3 (8)   DRY mode
4 (16)   ECO mode
5 (32)   VAC mode
6 (64)   MAN Mode with HEATING state

Parameter Number

Parameter Size

Parameter Name

Description

31 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

32 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

33 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

34 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

35 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

36 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

37 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

38 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

39 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

4 1 SOURCE TYPE Source Sensor: 1=A, 2=AF, 3=F, 4=FA, 5=P, 6=PA, 7=PF

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 1 7 No No No

Bit (Value)

 

Description

1 (2)   A – Air sensor. Regulation (heating control) is based on the SET POINT applied to the internal room air temperature sensor.
2 (4)   AF – Air sensor + Floor sensor. Regulation is based on SET POINT applied to the internal room temperature sensor but also controlled by the floor temperature sensor ensuring that the floor temperature remains within the set limits. The lower floor temperature limit is specified in Parameter 16 (FtL) and the high temperature limit in parameter 17 (FtH).
3 (8)   F – Floor sensor. Regulation is based on the SET POINT applied to the external floor temperature sensor.
4 (16)   FA – Floor sensor + Air sensor. Regulation is based on SET POINT applied to the external floor sensor but is also controlled by the internal air temperature sensor ensuring that the room temperature remains within the set limits. The lower air temperature limit is specified in Parameter 14 (AtL) and the higher temperature limit in Parameter 15 (AtH).
5 (32)   P – Power regulator. Regulation is based on the time settings for heating which will be ON during the time in Parameter 05 (POn) and then OFF during the time in Parameter 06 (POf). This cycle will be repeated constantly.
6 (64)   PA – Power regulator + Air sensor. Regulation is based on the time set by Parameters 05 and 06 but also controlled by the internal air temperature sensor ensuring that the room temperature remains within the set limits. The air temperature limits are specified in Parameters 14 and 15.
7 (128)   PF – Power regulator + Floor sensor. Regulation is based on the time set by Parameters 05 and 06 but also controlled by the floor temperature sensor ensuring that the floor temperature remains within set limits. The floor temperature limits are specified in Parameters 16 and 17.

Parameter Number

Parameter Size

Parameter Name

Description

40 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
1 (2)   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

41 1 SENSORS REPORT TIME Sensors consecutive reporting interval, minutes. When the device is connected to the Z-Wave gateway (controller), it periodically sends to the gateway reports from its room & floor temperature, humidity and light sensors even if there are not changes in the values. This Parameter defines the interval between consecutive reports. The value can be adjusted from 1 min to 120 min. Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value. In order not to increase traffic on your network, it is not recommended to reduce the value of this parameter. We recommend to reduce the value of this parameter only in case of poor connection, when reports from the device does not always reach the gateway.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 1 120 No No No

Value

 

Description

1   The value can be adjusted from 1 to 120 minutes

Parameter Number

Parameter Size

Parameter Name

Description

42 1 CONSUMPTION REPORT TIME Consumption meter consecutive reporting interval, minutes. This Parameter defines the interval between consecutive reports of real time and cumulative energy consumption data to the gateway. The value can be adjusted from 1 min to 120 min. The factory default value is 10 min. Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value. In order not to increase traffic on your network, it is not recommended to reduce the value of this parameter.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 1 120 No No No

Value

 

Description

1   The value can be adjusted from 1 to 120 minutes.

Parameter Number

Parameter Size

Parameter Name

Description

43 1 TEMPERATURE THRESHOLD Temperature difference to send to controller, value x10. This parameter determines the change in temperature level (in °C) resulting in temperature sensors report being sent to the gateway. The value of this parameter should be x10, e.g. for 0.4°C use value 40. From 0.5°C to 10°C can be selected. Use the value 0 if there is a need to stop sending the reports. The factory default value is 0.5°C (5).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 100 No No No

Value

 

Description

0   Stop sending the reports
5   Temperature level (in °C)

Parameter Number

Parameter Size

Parameter Name

Description

44 1 HUMIDITY THRESHOLD Humidity difference to send to controller, %. This parameter determines the change in humidity level in % resulting in humidity sensors report being sent to the gateway. From 2% to 25% can be selected. Use the value 0 if there is a need to stop sending the reports. The factory default value is 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 25 No No No

Value

 

Description

0   Stop sending the reports
2   Humidity level in %

Parameter Number

Parameter Size

Parameter Name

Description

45 1 LIGHT THRESHOLD Light sensor values difference to send to controller, %. This parameter determines the change in temperature level resulting in temperature sensors report being sent to the gateway. From 10% to 99% can be selected. Use the value 0 if there is a need to stop sending the reports. The factory default value is 50.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 0 99 No No No

Value

 

Description

0   Stop sending the reports
10   Temperature level change in %

Parameter Number

Parameter Size

Parameter Name

Description

46 2 MORNING START TIME Morning start time. Format: HHMM. e.g.08:00 should be sent as 0800

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

600 0 2359 No No No

Value

 

Description

0   Morning start time. Format: HHMM (from 00:00 to 23:59)

Parameter Number

Parameter Size

Parameter Name

Description

47 2 DAY START TIME Day start time. Format: HHMM.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

900 0 2359 No No No

Value

 

Description

0   Day start time. Format: HHMM (from 00:00 to 23:59)

Parameter Number

Parameter Size

Parameter Name

Description

48 2 EVENING START TIME Evening start time. Format: HHMM.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1800 0 2359 No No No

Value

 

Description

0   Evening start time. Format: HHMM (from 00:00 to 23:59)

Parameter Number

Parameter Size

Parameter Name

Description

49 2 NIGHT START TIME Night start time. Format: HHMM.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2300 0 2359 No No No

Value

 

Description

0   Night start time. Format: HHMM (from 00:00 to 23:59)

Parameter Number

Parameter Size

Parameter Name

Description

5 2 POWER REGULATION ON TIME Power Regulation ON time, min

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

30 10 240 No No No

Value

 

Description

10   This Parameter defines floor HEATING time in minutes when Power Regulator (P, PA or PF) is selected as the source sensor in Parameter 04. Time values can be changed in the range: 10 to 240 minutes.

Parameter Number

Parameter Size

Parameter Name

Description

50 2 MONDAY MORNING TEMP Monday Morning temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

240 40 370 No No No

Value

 

Description

40   Monday Morning temperature value

Parameter Number

Parameter Size

Parameter Name

Description

51 2 MONDAY DAYTIME TEMP Monday Day temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

200 40 370 No No No

Value

 

Description

40   Monday Day temperature value

Parameter Number

Parameter Size

Parameter Name

Description

52 2 MONDAY EVENING TEMP Monday Evening temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

230 40 370 No No No

Value

 

Description

40   Monday Evening temperature value

Parameter Number

Parameter Size

Parameter Name

Description

53 2 MONDAY NIGHT TEMP Monday Night temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

180 40 370 No No No

Value

 

Description

40   Monday Night temperature value

Parameter Number

Parameter Size

Parameter Name

Description

54 2 TUESDAY MORNING TEMP Tuesday Morning temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

240 40 370 No No No

Value

 

Description

40   Tuesday Morning temperature value

Parameter Number

Parameter Size

Parameter Name

Description

55 2 TUESDAY DAYTIME TEMP Tuesday Day temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

200 40 370 No No No

Value

 

Description

40   Tuesday Day temperature value

Parameter Number

Parameter Size

Parameter Name

Description

56 2 TUESDAY EVENING TEMP Tuesday Evening temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

230 40 370 No No No

Value

 

Description

40   Tuesday Evening temperature value

Parameter Number

Parameter Size

Parameter Name

Description

57 2 TUESDAY NIGHT TEMP Tuesday Night temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

180 40 370 No No No

Value

 

Description

40   Tuesday Night temperature value

Parameter Number

Parameter Size

Parameter Name

Description

58 2 WEDNESDAY MORNING TEMP Wednesday Morning temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

240 40 370 No No No

Value

 

Description

40   Wednesday Morning temperature value

Parameter Number

Parameter Size

Parameter Name

Description

59 2 WEDNESDAY DAYTIME TEMP Wednesday Day temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

200 40 370 No No No

Value

 

Description

40   Wednesday Day temperature value

Parameter Number

Parameter Size

Parameter Name

Description

6 2 POWER REGULATION OFF TIME Power Regulation OFF time, min

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

30 10 240 No No No

Value

 

Description

10   This Parameter defines floor IDLE time in minutes when Power Regulator (P, PA or PF) is selected as the source sensor in Parameter 04. Time can be changed in the range: 10 to 240 minutes.

Parameter Number

Parameter Size

Parameter Name

Description

60 2 WEDNESDAY EVENING TEMP Wednesday Evening temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

230 40 370 No No No

Value

 

Description

40   Wednesday Evening temperature value

Parameter Number

Parameter Size

Parameter Name

Description

61 2 WEDNESDAY NIGHT TEMP Wednesday Night temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

180 40 370 No No No

Value

 

Description

40   Wednesday Night temperature value

Parameter Number

Parameter Size

Parameter Name

Description

62 2 THURSDAY MORNING TEMP Thursday Morning temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

240 40 370 No No No

Value

 

Description

40   Thursday Morning temperature value

Parameter Number

Parameter Size

Parameter Name

Description

63 2 THURSDAY DAYTIME TEMP Thursday Day temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

200 40 370 No No No

Value

 

Description

40   Thursday Day temperature value

Parameter Number

Parameter Size

Parameter Name

Description

64 2 THURSDAY EVENING TEMP Thursday Evening temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

230 40 370 No No No

Value

 

Description

40   Thursday Evening temperature value

Parameter Number

Parameter Size

Parameter Name

Description

65 2 THURSDAY NIGHT TEMP Thursday Night temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

180 40 370 No No No

Value

 

Description

40   Thursday Night temperature value

Parameter Number

Parameter Size

Parameter Name

Description

66 2 FRIDAY MORNING TEMP Friday Morning temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

240 40 370 No No No

Value

 

Description

40   Friday Morning temperature value

Parameter Number

Parameter Size

Parameter Name

Description

67 2 FRIDAY DAYTIME TEMP Friday Day temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

200 40 370 No No No

Value

 

Description

40   Friday Day temperature value

Parameter Number

Parameter Size

Parameter Name

Description

68 2 FRIDAY EVENING TEMP Friday Evening temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

230 40 370 No No No

Value

 

Description

40   Friday Evening temperature value

Parameter Number

Parameter Size

Parameter Name

Description

69 2 FRIDAY NIGHT TEMP Friday Night temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

180 40 370 No No No

Value

 

Description

40   Friday Night temperature value

Parameter Number

Parameter Size

Parameter Name

Description

7 1 DRY TIME Dry Time, min

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

30 5 90 No No No

Value

 

Description

5   This Parameter specifies how long in minutes the Heating Thermostat will be in HEATING mode when the DRY mode is selected. After this time the HE-HT01 will enter the mode specified in Parameter 8. The time range is 5 to 90 minutes.

Parameter Number

Parameter Size

Parameter Name

Description

70 2 SATURDAY MORNING TEMP Saturday Morning temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

240 40 370 No No No

Value

 

Description

40   Saturday Morning temperature value

Parameter Number

Parameter Size

Parameter Name

Description

71 2 SATURDAY DAYTIME TEMP Saturday Day temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

200 40 370 No No No

Value

 

Description

40   Saturday Day temperature value

Parameter Number

Parameter Size

Parameter Name

Description

72 2 SATURDAY EVENING TEMP Saturday Evening temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

230 40 370 No No No

Value

 

Description

40   Saturday Evening temperature value

Parameter Number

Parameter Size

Parameter Name

Description

73 2 SATURDAY NIGHT TEMP Saturday Night temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

180 40 370 No No No

Value

 

Description

40   Saturday Night temperature value

Parameter Number

Parameter Size

Parameter Name

Description

74 2 SUNDAY MORNING TEMP Sunday Morning temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

240 40 370 No No No

Value

 

Description

40   Sunday Morning temperature value

Parameter Number

Parameter Size

Parameter Name

Description

75 2 SUNDAY DAYTIME TEMP Sunday Day temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

200 40 370 No No No

Value

 

Description

40   Sunday Day temperature value

Parameter Number

Parameter Size

Parameter Name

Description

76 2 SUNDAY EVENING TEMP Sunday Evening temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

230 40 370 No No No

Value

 

Description

40   Sunday Evening temperature value

Parameter Number

Parameter Size

Parameter Name

Description

77 2 SUNDAY NIGHT TEMP Sunday Night temperature, valueX10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

180 40 370 No No No

Value

 

Description

40   Sunday Night temperature value

Parameter Number

Parameter Size

Parameter Name

Description

8 1 DRY SWITCH MODE Mode to switch after Dry mode operation completion

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 6 No No No

Bit (Value)

 

Description

1 (2)   COM mode
2 (4)   TIME mode
4 (16)   ECO mode
5 (32)   VAC mode
6 (64)   MAN mode mode with IDLE state

Parameter Number

Parameter Size

Parameter Name

Description

9 1 TIME CORRECTION Time correction by controller

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Switch off auto-correction
1 (2)   If thermostat is connected to a Z-Wave gateway, the time and day will be periodically polled and corrected from the gateway