Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Nano Shutter (ZW141-C)

Z-Wave Certification Number: ZC10-19126810


Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Switch Type of External Switch 1 0
(Default)
Unidentified mode when no identify is set, and indicate identify fails when in identify.
  1 2-state switch mode
  2 3 way switch mode
  3 Push Button mode
  4 Enter automatic identification mode(The blue led will fast blink)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

121 1 Switch Type of External Switch 1 0
(Default)
Unidentified mode when no identify is set, and indicate identify fails when in identify.
  1 2-state switch mode
  2 3 way switch mode
  3 Push Button mode
  4 Enter automatic identification mode(The blue led will fast blink)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Motor Behavior After Power ON 0
(Default)
Stay the same position before power off last time
  1 Moves to 99%
  2 Moves to 0%

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Determine motor run direction 0
(Default)
Shutter mode / Venetian mode :Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0%
  1 Shutter mode : Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%. Venetian mode :Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0%
  2 Shutter mode : Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0% Venetian mode: Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%.
  3 Shutter mode / Venetian mode : Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

248 1 Function Setting of External Switch S1&S2 1
(Default)
Enable network function, inclusion/exclusion
  2 Enable reset to factory default function

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset Function 0
(Default)
Reset all configuration parameters to default settings
  1431655765 reset to factory default settings and removed from the z-wave network

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 2 Set the Blade Turn Time 10 to 32767
(Default)
0.1 - 327.67seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 2 Curtain Trip Time 500 to 32767
(Default)
5 - 327.67 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

36 1 Enter/Exit Calibration 0
(Default)
Set:Exit Calibration Report: Not in Calibration
  1 Set:Enter Shutter Mode Calibration Report: In Shutter Mode Calibration
  2 Set:Enter Venetian Mode Calibration Report: In Venetian Mode Calibration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

37 1 User confirmation for Calibration 0
(Default)
Go to next step of calibration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

38 1 Calibration Status Report 0
(Default)
Calibration Complete
  1 Calibration start, going to Reference Point A
  2 Reach Reference Point A, going to Reference Point B
  3 Reach Reference Point B, waiting for Blade turn Calibraion(Only for Venetian Mode)
  4 Going to Reference Point C(Only for Venetian Mode)
  5 Calibration terminated

Parameter Number

Parameter Size

Parameter Name

Parameter Values

39 1 Cutain Mode Setting 0
(Default)
Shutter Mode
  1 Venetian Mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Repositioning 1
(Default)
Repositioning begins

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Repositioning Status Report 0
(Default)
Repositioning complete
  1 in repositioning

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 Calibration Lock 0 Disable calibration
  1
(Default)
Enable Action Button/ Command Calibration
  2 Enable Action Button/ Command/S1/S2 Calibration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 Switch Status Report Selection 0 No Report
  1 Basic Report
  2
(Default)
Switch Multilevel Report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

85 1 Extern Button Mode Setting 0
(Default)
S1/S2 map to Z-Wave Button
  1 S1 = Open or Stop, S2 = Close or Stop Note:Operation will not change the curtain mode, including press and hold ,short press.
  2 1) When configuration 0x78/79 = 03: Press and hold S1 :blade folds to 180° Press and hold S2: Blade folds to 0° Short press S1: Blinds go downwards Short press S2: Blinds go upwards Note: The device will change its curtain mode if it does not match the current mode. 2) When Configuration 0x78/79 = others: S1 = Open or Stop,S2 = Close or Stop ,operation will not change the curtain mode.