TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Parameter 1 | 0 | All Relays OFF | |
1 (Default) |
All relays remember the status prior to power outage and turns back to it | ||||
2 | All relays turned on after power failure | ||||
3 | R1&R2 state recovered, R3 – OFF | ||||
4 | R1&R2 state recovered , R3-ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | Parameter 10 | 0 to 65535 (Default) |
The countdown time, Relay-3 OFF | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 4 | Parameter 11 | 0 to 65535 (Default) |
The countdown time, Relay-3 ON | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Parameter 12 | 0 | manual control disabled | |
1 (Default) |
manual control enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Parameter 13 | 0 (Default) |
manual control disabled | |
1 | manual control enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Parameter 14 | 0 (Default) |
manual control disabled | |
1 | manual control enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Parameter 2 | 0 | momentary switch | |
1 | toggle switch (contact closed -ON, contact opened - OFF) | ||||
2 (Default) |
toggle switch(device changes status when switch changes status) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Parameter 3 | 0 | momentary switch | |
1 | toggle switch (contact closed -ON, contact opened - OFF) | ||||
2 (Default) |
toggle switch(device changes status when switch changes status) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Parameter 4 | 0 | momentary switch | |
1 | toggle switch (contact closed -ON, contact opened - OFF) | ||||
2 (Default) |
toggle switch(device changes status when switch changes status) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Parameter 5 | 0 (Default) |
led OFF when output ON,led ON when output OFF | |
1 | led ON when output ON,led OFF when output OFF | ||||
2 | led always OFF | ||||
3 | led always ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 4 | Parameter 6 | 0 to 65535 (Default) |
The countdown time, Relay-1 OFF | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 4 | Parameter 7 | 0 to 65535 (Default) |
The countdown time, Relay-1 ON | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 4 | Parameter 8 | 0 to 65535 (Default) |
The countdown time, Relay-2 OFF | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 4 | Parameter 9 | 0 to 65535 (Default) |
The countdown time, Relay-2 ON | |