Z-Wave Products

There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: S100 Rocker for Dimmer (Mexico) (10005020-13x)

Z-Wave Certification Number: ZC10-20016852


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Association LED -128 Turns the central LED ON
  0
(Default)
Turns the LED OFF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Delay On -128 to -1 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution
  0
(Default)
Instantly. Disable timming
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Activation Time -128 to -1 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution
  0
(Default)
Instantly. Disable timming
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 behavior of LED in repose -128 Central LED on at 20% of maximum level
  0
(Default)
LED OFF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Lock Input -128 Lock the direct control of the load
  0
(Default)
Unlock the direct control of load.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Reset default (write only) -26521 Parameters, Groups, and Z-Wave status are restored to default.
  17170 Parameters, except Lock long press are restored to default

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 1 Delay OFF -128 to -1 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution
  0
(Default)
Instantly. Disable timming
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Press Action 0 when press t is less than 2sec device toggles the load. The Slider does not work
  1 when press t is less than 2secc device turns ON the load. The Slider does not works
  2 when press t is less than 2sec device turns OFF the load. The Slider does not works
  4 when press t is less than 2sec device turns ON the load. when press time is between 2 and 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action. The Slider does not works.
  5
(Default)
(default value) when press t is less than 2sec device toggles the load. The Slider dims the load when it is ON.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Identify (write only) -128
(Default)
Allows to identify a product using its central LED

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 2 State of charge (read only) -20480 Load is OFF
  -20479 Load is ON
  -20224 to -20125 Last active dimming value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Calibration required (read only) -128 It is necessary to calibrate the dimmer to work properly
  0
(Default)
Calibration is not required

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Lock long press -128 Hold Press from 2sec to 20 sec does not performs a Node info,Hold Press of 10 to 15 does not performs a automatic callibration,Hold press of 15 to 30 does not changes the sunblind or awing changes, Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network
  0
(Default)
Long press works as described previously

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Set time -128 to -1 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution
  0
(Default)
Instantly. Disable timming
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Fade Time -128 to -1 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution
  0
(Default)
Instantly. Disable timming
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Min dimming value % 1 to 99 Sets the minimum dimming value in percentage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Max dimming value 1 to 99
(Default)
Sets the maximum dimming value in percentage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Last on value 1 to 99
(Default)
Returns or sets the last non zero dimming value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Calibration 1
(Default)
Device performs calibration using Trailing and leading Edge and decides which one is better.
  2 Device is calibrated using Trailing Edge
  3 Device is calibrated using Leading Edge