There are over 4409 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Association LED | -128 | Turns the central LED ON | |
0 (Default) |
Turns the LED OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Delay On | -128 to -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | |
0 (Default) |
Instantly. Disable timming | ||||
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Activation Time | -128 to -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | |
0 (Default) |
Instantly. Disable timming | ||||
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | behavior of LED in repose | -128 | Central LED on at 20% of maximum level | |
0 (Default) |
LED OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Lock Input | -128 | Lock the direct control of the load | |
0 (Default) |
Unlock the direct control of load. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Reset default (write only) | -26521 | Parameters, Groups, and Z-Wave status are restored to default. | |
17170 | Parameters, except Lock long press are restored to default | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Delay OFF | -128 to -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | |
0 (Default) |
Instantly. Disable timming | ||||
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Press Action | 0 | when press t is less than 2sec device toggles the load. The Slider does not work | |
1 | when press t is less than 2secc device turns ON the load. The Slider does not works | ||||
2 | when press t is less than 2sec device turns OFF the load. The Slider does not works | ||||
4 | when press t is less than 2sec device turns ON the load. when press time is between 2 and 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action. The Slider does not works. | ||||
5 (Default) |
(default value) when press t is less than 2sec device toggles the load. The Slider dims the load when it is ON. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Identify (write only) | -128 (Default) |
Allows to identify a product using its central LED | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 2 | State of charge (read only) | -20480 | Load is OFF | |
-20479 | Load is ON | ||||
-20224 to -20125 | Last active dimming value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Calibration required (read only) | -128 | It is necessary to calibrate the dimmer to work properly | |
0 (Default) |
Calibration is not required | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Lock long press | -128 | Hold Press from 2sec to 20 sec does not performs a Node info,Hold Press of 10 to 15 does not performs a automatic callibration,Hold press of 15 to 30 does not changes the sunblind or awing changes, Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network | |
0 (Default) |
Long press works as described previously | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Set time | -128 to -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | |
0 (Default) |
Instantly. Disable timming | ||||
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Fade Time | -128 to -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | |
0 (Default) |
Instantly. Disable timming | ||||
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Min dimming value % | 1 to 99 | Sets the minimum dimming value in percentage | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Max dimming value | 1 to 99 (Default) |
Sets the maximum dimming value in percentage | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Last on value | 1 to 99 (Default) |
Returns or sets the last non zero dimming value. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Calibration | 1 (Default) |
Device performs calibration using Trailing and leading Edge and decides which one is better. | |
2 | Device is calibrated using Trailing Edge | ||||
3 | Device is calibrated using Leading Edge | ||||