There are over 4409 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Central LED | 0 (Default) |
Turns the LED OFF | |
255 | Turns the LED ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | On Timed | 0 (Default) |
Disables timing | |
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
128 to 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | OFF Timed | 0 (Default) |
Disables timing | |
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
128 to 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Load Lock | 0 (Default) |
Enables the push button to control the load | |
255 | Disables the action of the push button of the load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Reset default | 17170 | Parameters, except Lock long press are restored to default | |
39015 | Parameters, Groups, and Z-Wave status are restored to default | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Delayed OFF | 0 (Default) |
Disables timing | |
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
128 to 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Post Reset State | 0 | Restart with the relay disabled. | |
255 (Default) |
Recover the previous state. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Action when pressing | 0 (Default) |
When short press, device toggles the load | |
1 | When short press, device turns ON the load | ||||
2 | When short press, device turns OFF the load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | Custom Consumption Limit | 0 (Default) |
Disables custom consumption limit | |
1 to 65535 | Sets the power in Watts that is supported | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Identify | 255 | the central LED blinks for 5 seconds in order to identify the device | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Charge status | 45056 | Load is OFF | |
45057 | Load is ON | ||||
45312 | Load is OFF | ||||
45567 | Load is ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Lock key press | 0 (Default) |
Long press works as described previously | |
255 | Long press from 2 seconds to 30 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node info | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Beacon | 0 (Default) |
Disables the beacon function | |
1 to 99 | Sets the intensity of the beacon LEDs | ||||