Z-Wave Products

There are over 4407 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: S100 Master Rocker for Roller Blind (Mexico) (10005081-13x)

Z-Wave Certification Number: ZC10-20016839


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Association LED 0
(Default)
Turns the LED OFF
  255 Turns the LED ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Behavior of LED in repose 0
(Default)
LED OFF
  255 UP and DOWN LED on at 20 percent of maximum level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Lock Input 0
(Default)
Unlock the direct control of load
  255 Lock the direct control of load

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Reset default 17170 Parameters, except Lock long press are restored to default
  39015 Parameters, Groups, and Z-Wave status are restored to default

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Manual association lock 0
(Default)
Unblocked
  255 Blocked

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Press action 0 When short press, switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes.
  1
(Default)
When short press, always activates those associated with the last power on by sending a Basic Set to 0xFF
  2 When short press, always deactivates associates by sending a Basic Set to 0x00
  3 When short press, on the left side sends a Basic Set to 0x00 and the DOWN 5s LED lights up. By short press, on the right side. A Basic Set is sent to 0xFF and the UP 5s led is lit.
  4 When short press, always activates the associated nodes by sending a Basic Set to 0xFF. Pressing from 2 seconds to 10 seconds, always turns off the associated nodes by sending a Basic Set to 0x00. Does not send Node Info nor does the central LED flash.
  6 When short press, on the left side sends a Basic Set with VALUE OFF or 0x00 (depending on whether an OFF VALUE has been set). If VALUE OFF is set, the DOWN LED lights up for 5sec. Otherwise the UP and DOWN LEDs will be activated briefly. When short press, on dich side sends a Basic Set to VALUE ON or 0x00 (depending on whether an ON VALUE has been set). If VALUE ON is set, the UP LED is lit for 5 seconds. Otherwise the UP and DOWN LEDs will be activated briefly.
  7 The associated nodes are controlled as described in the USE table KEYBOARD AND ANSWERS

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Identify 255 the central LED blinks for 5 seconds in order to identify the device

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 2 Device state 45056 Stop
  45057 Going up
  45058 Going down
  45312 Percentage of Height of the blind

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 OFF VALUE 1 to 99 Set the value of OFF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 1 ON VALUE 1 to 99 Set the value of ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Lock long press 0
(Default)
Long press works as described previously
  255 Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

28 1 Consult on Touch detection 0
(Default)
If there is 1 Associated device, when Touch is detected, controlled device state will be consulted
  255 If there is 1 Associated device, when Touch is detected, controlled device state is not consulted.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

29 1 Enable automatic reporting CENTRAL_SCENE 0
(Default)
Enables CC Central Scene Notification when there are no nodes associated with the control group and Inhibits error signaling by pressing less than 2 seconds if there are no associated nodes.
  255 Enables error signaling by pressing less than 2 seconds if there are no associated nodes