There are over 4407 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Association LED | 0 (Default) |
Turns the LED OFF | |
255 | Turns the LED ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Behavior of LED in repose | 0 (Default) |
LED OFF | |
255 | UP and DOWN LED on at 20 percent of maximum level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Lock Input | 0 (Default) |
Unlock the direct control of load | |
255 | Lock the direct control of load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Reset default | 17170 | Parameters, except Lock long press are restored to default | |
39015 | Parameters, Groups, and Z-Wave status are restored to default | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Manual association lock | 0 (Default) |
Unblocked | |
255 | Blocked | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Press action | 0 | When short press, switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. | |
1 (Default) |
When short press, always activates those associated with the last power on by sending a Basic Set to 0xFF | ||||
2 | When short press, always deactivates associates by sending a Basic Set to 0x00 | ||||
3 | When short press, on the left side sends a Basic Set to 0x00 and the DOWN 5s LED lights up. By short press, on the right side. A Basic Set is sent to 0xFF and the UP 5s led is lit. | ||||
4 | When short press, always activates the associated nodes by sending a Basic Set to 0xFF. Pressing from 2 seconds to 10 seconds, always turns off the associated nodes by sending a Basic Set to 0x00. Does not send Node Info nor does the central LED flash. | ||||
6 | When short press, on the left side sends a Basic Set with VALUE OFF or 0x00 (depending on whether an OFF VALUE has been set). If VALUE OFF is set, the DOWN LED lights up for 5sec. Otherwise the UP and DOWN LEDs will be activated briefly. When short press, on dich side sends a Basic Set to VALUE ON or 0x00 (depending on whether an ON VALUE has been set). If VALUE ON is set, the UP LED is lit for 5 seconds. Otherwise the UP and DOWN LEDs will be activated briefly. | ||||
7 | The associated nodes are controlled as described in the USE table KEYBOARD AND ANSWERS | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Identify | 255 | the central LED blinks for 5 seconds in order to identify the device | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 2 | Device state | 45056 | Stop | |
45057 | Going up | ||||
45058 | Going down | ||||
45312 | Percentage of Height of the blind | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
25 | 1 | OFF VALUE | 1 to 99 | Set the value of OFF | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
26 | 1 | ON VALUE | 1 to 99 | Set the value of ON | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Lock long press | 0 (Default) |
Long press works as described previously | |
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
28 | 1 | Consult on Touch detection | 0 (Default) |
If there is 1 Associated device, when Touch is detected, controlled device state will be consulted | |
255 | If there is 1 Associated device, when Touch is detected, controlled device state is not consulted. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
29 | 1 | Enable automatic reporting CENTRAL_SCENE | 0 (Default) |
Enables CC Central Scene Notification when there are no nodes associated with the control group and Inhibits error signaling by pressing less than 2 seconds if there are no associated nodes. | |
255 | Enables error signaling by pressing less than 2 seconds if there are no associated nodes | ||||