There are over 4409 interoperable
Group ID | Group Profile Name | Profile | Maximum Nodes | Description | Endpoint ID | Commands |
---|---|---|---|---|---|---|
1 | Lifeline | 3 | Z-Wave Plus Lifeline Position Report when Sunblind is stopped and is changed: - % new position -> CC Basic, Basic Report, Value 0xXX from 0x00 to 0x63 Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line). - Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF - Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00 After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent. | 0 | ||
2 | Control | 20 | Ctrl When Touch area is detected o key is pressed without touch area detection: CC Configuration, Configuration Get, Param 21 -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is a Simon device. Used to know the associated device state. CC Basic, Basic Get -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is not a Simon device. Used to know the associated device state. COMMAND_CLASS_BASIC_REPORT Associates are sent when the sunblind remains stoped for 1.5s after changing positions. % New position -> CC Basic, Basic Report, Value 0x00 - 0x63 | 0 |