Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: S100 Rocker for Roller Blind (Mexico) (10005080-13x)

Z-Wave Certification Number: ZC10-20016843


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Association LED 0
(Default)
Turns the LED OFF
  255 to 0 Turns the LED ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Behavior of LED in repose 0
(Default)
LED OFF
  255 LED on at 20 percent of maximum level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Lock Input 0
(Default)
Unlock the direct control of load.
  255 Lock the direct control of load

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Calibration 255 Sunblind starts its callibration process

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Reset Default 17170 Parameters, except Lock long press are restored to default
  39015 Parameters, Groups, and Z-Wave status are restored to default

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Identify 255 The central LED blinks for 5 seconds in order to identify the device

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Device state 45056 LED OFF
  45057 LED ON
  45312 LED OFF
  45567 LED ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Calibration required 0
(Default)
Calibration is not required
  255 It is necessary to calibrate the curtain to work properly

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Operating Mode 0 Operating mode for Window Shutter
  255
(Default)
Operating Mode for SundBlinds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Lock long press 0
(Default)
Long press works as described previously
  255 Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 UP Time 0
(Default)
Instantly
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
  128 to 255 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 DOWN Time 0
(Default)
Instantly
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
  128 to 254 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution