There are over 4409 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Association LED | 0 (Default) |
Turns the LED OFF | |
255 | Turns the LED ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Delay ON | 0 (Default) |
Disables timing | |
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
128 to 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Activation TIME | 0 (Default) |
Disables timing | |
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
128 to 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Behaviour of LED in repose | 0 (Default) |
LED OFF | |
255 | LED on at 20 percent of maximum level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Lock Input | 0 (Default) |
Unlock the direct control of load | |
255 | Lock the direct control of load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Reset default | 17170 | Parameters, except Lock long press are restored to default | |
39015 | Parameters, Groups, and Z-Wave status are restored to default value. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Delay OFF | 0 (Default) |
Disables timing | |
1 to 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution | ||||
128 to 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Press action | 0 (Default) |
When short press, device toggles the load | |
1 | When short press, device turns ON the load | ||||
2 | When short press, device turns OFF the load | ||||
4 | When short press, device turns ON the load. When hold press from 2 seconds to 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Identify | 255 | the central LED blinks for 5 seconds in order to identify the device | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | State of charge | 45056 | Load is OFF | |
45057 | Load is ON | ||||
45312 | Load is OFF | ||||
45567 | Load is ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Calibration Required | 0 (Default) |
Calibration is not required | |
255 | It is necessary to calibrate the dimmer to work properly | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Lock long press | 0 (Default) |
Long press works as described previously | |
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Calibration | 1 | Device performs calibration using Trailing and leading Edge and decides which one is better | |
2 | Device is calibrated using Trailing Edge. | ||||
3 | Device is calibrated using Leading Edge | ||||