TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Thermostatic Radiator Valve (AC301-1)

Z-Wave Certification Number: ZC10-19126824


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 Temperature Auto Report period setting 1 to 255
(Default)
1~255(min)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Manual Override takeover period 1 to 48
(Default)
1~48 means 30mins to 24hrs

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Temperature offset for internal sensor -80 to 80
(Default)
-80~+80 offsets the measured temperature by -8.0℃~+8.0℃

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Maximum Set point value 5 to 35
(Default)
5~35 for 5℃~35℃

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Minimum Set point value 5 to 35
(Default)
5~35 for 5℃~35℃

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Frost protection temperature 5 to 15
(Default)
5~15 for 5℃~15℃

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Open window detect function 0 to 1
(Default)
0: Disable;1: Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Open window detect time period 2 to 30
(Default)
2~30(min)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 open window detect temperature drop setting 4 to 8
(Default)
4=2℃;5=2.5℃;6= 3℃;7=3.5℃;8=4℃

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Open window detect delay time select 10 to 60
(Default)
10~60(min)