TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Temperature Auto Report period setting | 1 to 255 (Default) |
1~255(min) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Manual Override takeover period | 1 to 48 (Default) |
1~48 means 30mins to 24hrs | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Temperature offset for internal sensor | -80 to 80 (Default) |
-80~+80 offsets the measured temperature by -8.0℃~+8.0℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Maximum Set point value | 5 to 35 (Default) |
5~35 for 5℃~35℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Minimum Set point value | 5 to 35 (Default) |
5~35 for 5℃~35℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Frost protection temperature | 5 to 15 (Default) |
5~15 for 5℃~15℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Open window detect function | 0 to 1 (Default) |
0: Disable;1: Enable | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Open window detect time period | 2 to 30 (Default) |
2~30(min) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | open window detect temperature drop setting | 4 to 8 (Default) |
4=2℃;5=2.5℃;6= 3℃;7=3.5℃;8=4℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Open window detect delay time select | 10 to 60 (Default) |
10~60(min) | |