TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Z-Wave Puck (1414140)

Z-Wave Certification Number: ZC10-20016847


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Minimum brightness level 10 to 15
(Default)
The minimum brightness that the dimmer can achieve is 15.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 S1 Scene ID set 1 to 3
(Default)
When you press S1 five times,the light is dimmed to the brightness set in Scene ID 3 .

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 S2 Scene ID set 2 to 5
(Default)
When you press S1 five times,the light is dimmed to the brightness set in Scene ID 5.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Timer functionality (auto - off) 0 to 20
(Default)
The device will automatically switch off after 20s from switching on the light source.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Maximum brightness level 90 to 98 The maximum brightness that the dimmer can achieve is 98.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Automatic control - dimming step size 1 to 2
(Default)
The percentage value of dimming step during the automatic control is 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 2 Automatic control - time of a dimming step 1 to 2
(Default)
The time of single dimming step set in parameter 3 during the automatic control is 20ms.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Manual control - dimming step size 1 to 2
(Default)
The percentage value of dimming step during the manual control is 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Manual control - time of a dimming step 3 to 5
(Default)
The time of single dimming step set in parameter 5 during the manual control is 50ms.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Memory function after power failure 1 to 0 The Device will not restore its brightness before power failure.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Switch type 0 to 1
(Default)
If the device is connected to ON/OFF switch,This parameter must set to 1.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Switch functionality of S1 and S2 0 to 1
(Default)
The device performs S2 function when S1 is pressed, and S1 function when S2 is pressed.