Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Minimum brightness level | 1 to 98 (Default) |
Set the desired value from 1 to 98% for the minimum dim level that the dimmer is restricted to; the dimmer will not go lower than the value set here. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Maximum brightness level | 2 to 99 (Default) |
Set the desired value from 2 to 99% for the maximum dim level that the dimmer is restricted to; the dimmer will not go higher than the value set here. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Automatic control - dimming step size | 1 to 99 (Default) |
Set the desired value from 1 to 99% for dim step size;The dimmer is dimmed up or down based on the percentage of the value set here for each step during the automatic control. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Automatic control - time of a dimming step | 1 to 255 (Default) |
Set the desired value from 1 to 255(10ms-2.55s,in 10ms steps) for the time of a dimming step. The amount of time the dimmer takes to adjust each step during the automatic control is the value set here. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Manual control - dimming step size | 1 to 99 (Default) |
Set the desired value from 1 to 99% for dim step size;The dimmer is dimmed up or down based on the percentage of the value set here for each step during the manual control. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Manual control - time of a dimming step | 1 to 255 (Default) |
Set the desired value from 1 to 255(10ms-2.55s,in 10ms steps) for the time of a dimming step. The amount of time the dimmer takes to adjust each step during the manual control is the value set here. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Memory function after power failure | 0 to 1 (Default) |
Set the desired value from 0 to 1 to turn on/off the memory function.Setting this value to 0 turns off the dimmer's Memory fucntion.Setting this value to 1 truns on the dimmer's Memory function. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Scene ID set | 1 to 255 (Default) |
Set the desired number from 1 to 255 as current scene ID.The dimmer will drive the load lamp based on the brightness stored in the scene ID set here,when the scene function is triggered.But the brightness value stored in each scene ID is set by the SCENE_ACTUATOR_CONF(0X26) command | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Timer functionality (auto - off) | 0 to 32767 (Default) |
Set the desired value from 0 to 32767(0--Function disable,1-32767--1s-32767s) fas the time at which the dimmer will automatically turn off.Setting this value to 0 will disable the dimmer's countdown function.Set this value to 1-32767 and the dimmer will turn off when the dimmer countdown reaches the set value. | |