TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | LED Indicator Mode for Dimmer | 0 (Default) |
On when off and off when on | |
1 | On when on and off when off | ||||
2 | Always off | ||||
3 | Always on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | Auto Turn-Off Timer for Relay | 0 to 65535 (Default) |
The countdown time, the Relay off | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 4 | Auto Turn-On Timer for Relay | 0 to 65535 (Default) |
The countdown time, the Relay on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Restores state after power failure | 0 | dimmer, relay off | |
1 | dimmer off, relay on | ||||
2 | dimmer on, relay off | ||||
3 (Default) |
previous state for dimmer, previous state for relay | ||||
4 | previous state for dimmer, relay on | ||||
5 | previous state for dimmer, relay off | ||||
6 | dimmer on, previous state for relay | ||||
7 | dimmer off, previous state for relay | ||||
8 | dimmer on, relay on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Ramp rate | 0 to 99 (Default) |
from 0x63 to 0x00 or from 0x00 to 0x63 need Required time | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Multilevel minimum value can be set | 0 to 99 (Default) |
The minimum brightness of a dimmer | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Multilevel maximum value can be set | 0 to 99 (Default) |
The maximum brightness of a dimmer | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | when switch is on or off and quickly press UPPER paddle 2 times, | 0 (Default) |
turn on to 99 | |
1 | turn on to the value relate with parameter 15 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Double Tap Behavior | 0 (Default) |
enable double tap to full brightness, single tap to last brightness level or custom value set in parameter 23 | |
1 | disable double tap to full brightness, single tap to last brightness level or custom value set in parameter 23 | ||||
2 | isable double tap to full brightness, single tap always to full brightness | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Enable or Disable local / Z-Wave control for DIMMER | 0 | disable local on/off control | |
1 (Default) |
enable local and Z-Wave control (normal operation like now) | ||||
2 | disable local and Z-Wave on/off control | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | LED Indicator Mode for Relay | 0 (Default) |
On when off and off when on | |
1 | On when on and off when off | ||||
2 | Always off | ||||
3 | Always on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Enable or Disable local / Z-Wave control for RELAY | 0 | disable local on/off control | |
1 (Default) |
enable local and Z-Wave control (normal operation like now) | ||||
2 | disable local and Z-Wave on/off control | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Dimmer Speed Setting (only for local press & hold) | 0 to 99 (Default) |
Time required for local key dimming | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Ramp rate for Z-Wave on/off controlled | 0 (Default) |
on/off ramp rate for Z-Wave same as manual control (set in Parameter 13) | |
1 | on/off ramp rate for Z-Wave control set through command class (like now) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | default brightness level | 0 to 99 (Default) |
in this parameter define default brightness level | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | LED Indicator Color for Dimmer | 0 (Default) |
White | |
1 | Blue | ||||
2 | Green | ||||
3 | Red | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | LED Indicator Color for Relay | 0 (Default) |
White | |
1 | Blue | ||||
2 | Green | ||||
3 | Red | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | LED Indicator Brightness for Dimmer | 0 | Bright (100%) | |
1 (Default) |
Medium (60%) | ||||
2 | Low (30%) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | LED Indicator Brightness for Relay | 0 | Bright (100%) | |
1 (Default) |
Medium (60%) | ||||
2 | Low (30%) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | LED Indicator Mode for Scene | 0 | Enable | |
1 (Default) |
Disable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 4 | Auto Turn-Off Timer for Dimmer | 0 to 65535 (Default) |
The countdown time, the Dimmer Off | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 4 | Auto Turn-On Timer for Dimmer | 0 to 65535 (Default) |
The countdown time, the dimmer on | |