There are over 4401 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Parameter 1 | 0 | Setting this parameter to 0 will disable central scene notifications for multiple (2x-5x) button presses). | |
1 (Default) |
Setting this parameter to 1 will enable central scene notifications for multiple (2x-5x) button presses). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | Parameter 2 | 0 | Disable unsolicited meter reports of current wattage. | |
3 to 8640 (Default) |
Interval of unsolicited reports in 10s increments (30 seconds - 1 day) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 2 | Parameter 3 | 0 | Disable unsolicited meter reports of active energy. | |
10 to 30240 (Default) |
Interval of unsolicited reports in minutes (10 minutes - 3 weeks) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Parameter 4 | 0 (Default) |
In this mode the top button will turn the output on, while the bottom button will turn the output off. | |
1 | In this mode any button press will toggle the output - when on it will be turned off, when off it will be turned on. | ||||