TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | On Off Status After Power Failure | 0 | ALL relays forced to OFF (regardless of state prior to power outage); | |
1 (Default) |
ALL relays remember and restore on/off status after power failure | ||||
2 | ALL relays forced to ON (regardless of state prior to power outage); | ||||
3 | Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to OFF; | ||||
4 | Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to ON. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 4 | Auto Turn-Off Timer for Relay 3 | 0 (Default) |
timer disabled | |
1 to 65535 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 4 | Auto Turn-On Timer for Relay 3 | 0 (Default) |
timer disabled | |
1 to 65535 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Enable/Disable Manual Control for Sw1 | 0 | local control disabled | |
1 (Default) |
local control enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Enable/Disable Manual Control for Sw2 | 0 | local control disabled | |
1 (Default) |
local control enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Enable/Disable Manual Control for Sw3 | 0 | local control disabled | |
1 (Default) |
local control enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Switch Type for Relay 1 (Sw1) | 0 | momentary switch | |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); | ||||
2 (Default) |
toggle switch (state changes whenever the switch is toggled). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Switch Type for Relay 2 (Sw2) | 0 | momentary switch | |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); | ||||
2 (Default) |
toggle switch (state changes whenever the switch is toggled) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Switch Type for Relay 3 (Sw3) | 0 | momentary switch | |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) | ||||
2 (Default) |
toggle switch (state changes whenever the switch is toggled) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | LED Indicator Control | 0 (Default) |
LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default); | |
1 | LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off | ||||
2 | LED indicator is always OFF | ||||
3 | LED indicator is always ON. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 4 | Auto Turn-Off Timer for Relay 1 | 0 (Default) |
timer disabled | |
1 to 65535 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 4 | Auto Turn-On Timer for Relay 1 | 0 (Default) |
timer disabled | |
1 to 65535 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 4 | Auto Turn-Off Timer for Relay 2 | 0 (Default) |
timer disabled | |
1 to 65535 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 4 | Auto Turn-On Timer for Relay 2 | 0 (Default) |
timer disabled | |
1 to 65535 | minutes | ||||