Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Mini Dimmer (ZMNHHD3)

Z-Wave Certification Number: ZC10-20086956


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Parameter no. 1 – In-wall Switch Type for Load ( ) to control terminal I 0
(Default)
momentary
  1 on/off toggle switch

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Parameter no. 11 - Turn Load 1 ( ) Off Automatically with Timer 0
(Default)
Auto OFF Disabled
  1 to 32536 Auto OFF timer enabled for a given number of seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Parameter no. 12 - Turn Load 1 ( ) On Automatically with Timer 0
(Default)
Auto ON Disabled
  1 to 32536 Auto ON timer enabled for a given amount of seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Parameter no. 21 - Enable/Disable the Double click function 0
(Default)
double click disabled
  1 double click enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Parameter no. 30 - Restore on/off status for load after power failure 0
(Default)
Device saves last on/off status and restores it after a power failure.
  1 Device does not save on/off status and does not restore it after a power failure, it remains off.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Parameter no. 40 – Watt Power Consumption Reporting Threshold for Load 0 Power consumption reporting disabled
  1 to 100
(Default)
= 1 % - 100 % Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1 % (the lowest value possible).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Parameter no. 42 – Watt Power Consumption Reporting Time Threshold for Load 0
(Default)
Power consumption reporting on time interval disabled
  30 to 32767 30 – 32767 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Parameter no. 5 – Working mode 0
(Default)
Dimmer mode
  1 Switch mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Parameter no. 60 – Minimum dimming value 0
(Default)
0 % (minimum dimming value)
  1 to 98 1 % - 98 %, step is 1 %. Minimum dimming value is set by entering a value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 1 Parameter no. 61 – Maximum dimming value 99
(Default)
99 % (Maximum dimming value)
  2 to 99
(Default)
2 % - 99 %, step is 1 %. Maximum dimming value is set by entering a value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 1 Parameter no. 65 – Dimming time when key pressed (soft on/off) 1
(Default)
1 s
  1 to 127
(Default)
1 seconds- 127 seconds, step is 1 second

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Parameter no. 66 – Dimming time when key hold 1 to 127
(Default)
1 second – 127 seconds
  128 to 253 1 minute – 126 minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

67 1 Parameter no. 67 – Ignore start level 0
(Default)
use the start level value
  1 ignore the start level value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

68 1 Parameter no. 68 – Dimming duration 0
(Default)
(dimming duration according to parameter 66)
  1 to 127 (from 1 to 127 seconds) ⓘ NOTE: Parameter is valid only in Dimmer mode. In Switch mode the parameter has no effect.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

70 2 Parameter no. 70 - Overload safety switch 1 to 200
(Default)
1 W – 200 W
  0 function not active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

71 1 Parameter no. 71 – Calibration trigger 0
(Default)
calibration done after power cycle if module is excluded
  1 calibration done after power cycle regardless of inclusion status
  2 force calibration. Calibration will start immediately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

72 1 Parameter no. 72 – Calibration status (read only) 1 calibration was successful
  2
(Default)
calibration failed

Parameter Number

Parameter Size

Parameter Name

Parameter Values

73 1 Parameter no. 73 – Alarm/Notification events 0
(Default)
default value 0 – function not active
  1 turn ON
  2 turn OFF
  3 start blinking (output turns 1 s ON, and 1 s OFF)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

74 1 Parameter no. 74 – Alarm/Notification time interval (dependant on parameter 73) 10
(Default)
10 minutes
  1 to 125
(Default)
1 -125 minutes