Z-Wave Products

There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Double Switch (ZEN30)

Z-Wave Certification Number: ZC10-20026859


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 LED Indicator Mode for Dimmer 0
(Default)
LED indicator is on when switch is off, LED indicator is off when switch is on (default);
  1 LED indicator is on when switch is on, LED indicator is off when switch is off;
  2 LED indicator is always OFF and LED’s don’t indicate brightness level during dimming;
  3 LED indicator is always ON.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 4 Auto Turn-Off Timer for Relay 0
(Default)
timer disabled
  1 to 65535 minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 4 Auto Turn-On Timer for Relay 0
(Default)
timer disabled
  1 to 65535 minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 On Off Status A􀈇er Power Failure 0 dimmer and relay forced to OFF (regardless of state prior to power outage);
  1 dimmer forced to off, relay forced to on;
  2 dimmer forced to on, relay forced to off;
  3
(Default)
remembers and restores on/off status for dimmer and relay a􀈇er power failure (default);
  4 remembers and restores on/off status for dimmer, relay forced to on;
  5 remembers and restores on/off status for dimmer, relay forced to off;
  6 dimmer forced to on, remembers and restores on/off status for relay;
  7 dimmer forced to off, remembers and restores on/off status for relay;
  8 dimmer and relay forced to ON.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Ramp Rate Control for Dimmer 0 instant on/off;
  1 to 99
(Default)
seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Minimum Brightness 1 to 99
(Default)
% brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Maximum Brightness 1 to 99
(Default)
% brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Double Tap Function for Dimmer 0
(Default)
the light will turn on to full brightness with double tap (default).
  1 the light will turn on to the maximum brightness level set in Parameter 15 with double tap.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Double Tap Function for Dimmer: Disable/Enable 0
(Default)
double tap to full / maximum brightness level enabled (default).
  1 double tap to full / maximum brightness level disabled, single tap turns light on to last brightness level (or custom value set in Parameter 23)
  2 double tap to full / maximum brightness level disabled, single tap turns light on to full brightness level.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Enable/Disable Load Control for Dimmer (Smart Bulb Setting) 0 manual control disabled.
  1
(Default)
manual control enabled
  2 manual and Z-Wave control disabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 LED Indicator Control for Relay 0
(Default)
LED indicator is on when relay is off, LED indicator is off when relay is on (default);
  1 LED indicator is on when relay is on, LED indicator is off when relay is off;
  2 LED indicator is always OFF
  3 LED indicator is always ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Enable/Disable Load Control for Relay (Remote Control Setting) 0 manual control disabled.
  1
(Default)
manual control enabled
  2 manual and Z-Wave control disabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Manual Dimming Speed 1 to 99
(Default)
seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Z-Wave Ramp Rate for Dimmer 0
(Default)
Z-Wave on/off ramp rate matches the manual ramp rate set in Parameter 13.
  1 Z-Wave on/off ramp rate is set separately through its command class in the hub.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Custom Brightness Level On for Dimmer 0
(Default)
last brightness level
  1 to 99 % brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 LED Indicator Color for Dimmer 0
(Default)
white
  1 blue
  2 green
  3 red

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 LED Indicator Color for Relay 0
(Default)
white
  1 blue
  2 green
  3 red

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 LED Indicator Brightness for Dimmer 0 bright (100%)
  1
(Default)
medium (60%)
  2 low (30%)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 LED Indicator Brightness for Relay 0 bright (100%)
  1
(Default)
medium (60%)
  2 low (30%)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 LED Indicator Mode for Scene Control 0 LED’s enabled to indicate scene triggers;
  1
(Default)
LED’s disabled to indicate scene triggers (default).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 4 Auto Turn-Off Timer for Dimmer 0
(Default)
timer disabled
  1 to 65535 minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 4 Auto Turn-On Timer for Dimmer 0
(Default)
timer disabled
  1 to 65535 minutes