There are over 4377 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Parameter 1 | 0 | Setting this parameter to 0 will disable central scene notifications for multiple (2x-5x) button presses. | |
1 (Default) |
Setting this parameter to 1 will enable central scene notifications for multiple (2x-5x) button presses. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | Parameter 2 | 0 | Disable unsolicited meter reports of current wattage. | |
3 to 8640 (Default) |
Interval of current wattage meter unsolicited reports in 10s increments (30 seconds - 1 day) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 2 | Parameter 3 | 0 | Disable unsolicited meter reports of active energy. | |
10 to 30240 (Default) |
Interval of active energy meter unsolicited reports in minutes (10 minutes - 3 weeks) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Parameter 4 | 0 (Default) |
T1 turns output L1 on, T2 turn output L1 off | |
1 | T1 and T2 toggle output L1 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Parameter 5 | 0 (Default) |
a toggle switch type is connected to extension connector S | |
1 | a push button switch type is connected to extension connector S | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Parameter 6 | 1 (Default) |
map extension input S to central scene of T1 | |
2 | map extension input S to central scene of T2 | ||||
3 | map extension input S to own central scene | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Parameter 7 | 0 (Default) |
select dimming curve 1 | |
1 | select dimming curve 2 | ||||