There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Unit of Accumulated Water Flow | 1 | 1 : US Gallon | |
2 (Default) |
2. KL | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | Threshold of Accumulated Water Flow | 0 | 0 : Disable accumulated meter report | |
1 to 255 (Default) |
1~255 : 1~255 US Gallon or KL | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Differential of Instant Water Flow | 0 | 0 : Disable instant water flow Report | |
1 to 100 (Default) |
1~100 : 1% ~ 100% | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Pulse count per liter | 1 to 32767 (Default) |
450 Pulse/L | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Relay Control mode | 0 (Default) |
0 : NC | |
1 | 1 : NO | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Periodic Auto Report Timer | 0 | 0 : Disable Periodic Auto Report | |
1 to 1440 (Default) |
1~1440 :1min ~ 1440 min | ||||