There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Association Capabilities

Model: Touch Panel Switch (HE-TPS05)

Z-Wave Certification Number: ZC12-20030039


Group ID Group Profile Name Profile Maximum Nodes Description Endpoint ID Commands
1 Lifeline 0x0001 1 This is the Lifeline Group 1 which sends status (lifeline) reports to the primary controller. 0
2 Touch 1 Basic Set 0x2001 1 Group 2 – “Touch 1 Basic Set”: is assigned to touch N1. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 0
3 Touch 1 Multilevel Set 0x2001 1 Group 3 – “Touch 1 Multilevel Set”: is assigned to touch N1. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. 0
4 Touch 2 Basic Set 0x2002 1 Group 4 – “Touch 2 Basic Set”: is assigned to touch N2. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 0
5 Touch 2 Multilevel Set 0x2002 1 Group 5 – “Touch 2 Multilevel Set”: is assigned to touch N2. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. 0
6 Touch 3 Basic Set 0x2003 1 Group 4 – “Touch 3 Basic Set”: is assigned to touch N3. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 0
7 Touch 3 Multilevel Set 0x2003 1 Group 7 – “Touch 3 Multilevel Set”: is assigned to touch N3. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. 0
8 Touch 4 Basic Set 0x2004 1 Group 8 – “Touch 4 Basic Set”: is assigned to touch N4. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 0
9 Touch 4 Multilevel Set 0x2004 1 Group 9 – “Touch 4 Multilevel Set”: is assigned to touch N4. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. 0
10 Touch 5 Basic Set 0x2005 1 Group 10 – “Touch 5 Basic Set”: is assigned to touch N5. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 0
11 Touch 5 Multilevel Set 0x2005 1 Group 11 – “Touch 5 Multilevel Set”: is assigned to touch N5. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. 0
12 LED 1 Basic Set 0x2006 1 Group 12 – “LED 1 Basic Set”: is assigned to LED N1. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 1
13 LED 2 Basic Set 0x2007 1 Group 13 – “LED 2 Basic Set”: is assigned to LED N2. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 2
14 LED 3 Basic Set 0x2008 1 Group 14 – “LED 3 Basic Set”: is assigned to LED N3. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 3
15 LED 4 Basic Set 0x2009 1 Group 14 – “LED 4 Basic Set”: is assigned to LED N4. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 4
16 LED 5 Basic Set 0x200A 1 Group 16 – “LED 5 Basic Set”: is assigned to LED N5. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 5
17 Relay 1 Basic Set 0x200B 1 Group 17 – “Relay 1 Basic Set”: is assigned to relay N1. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 6
18 Relay 2 Basic Set 0x200C 1 Group 18 – “Relay 2 Basic Set”: is assigned to relay N2. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 7
19 Relay 3 Basic Set 0x200D 1 Group 19 – “Relay 3 Basic Set”: is assigned to relay N3. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 8
20 Relay 4 Basic Set 0x200E 1 Group 20 – “Relay 4 Basic Set”: is assigned to relay N4. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. 9