There are over 4377 interoperable
Group ID | Group Profile Name | Profile | Maximum Nodes | Description | Endpoint ID | Commands |
---|---|---|---|---|---|---|
1 | Lifeline | 0x0001 | 1 | This is the Lifeline Group 1 which sends status (lifeline) reports to the primary controller. | 0 | |
2 | Touch 1 Basic Set | 0x2001 | 1 | Group 2 – “Touch 1 Basic Set”: is assigned to touch N1. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 0 | |
3 | Touch 1 Multilevel Set | 0x2001 | 1 | Group 3 – “Touch 1 Multilevel Set”: is assigned to touch N1. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. | 0 | |
4 | Touch 2 Basic Set | 0x2002 | 1 | Group 4 – “Touch 2 Basic Set”: is assigned to touch N2. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 0 | |
5 | Touch 2 Multilevel Set | 0x2002 | 1 | Group 5 – “Touch 2 Multilevel Set”: is assigned to touch N2. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. | 0 | |
6 | Touch 3 Basic Set | 0x2003 | 1 | Group 4 – “Touch 3 Basic Set”: is assigned to touch N3. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 0 | |
7 | Touch 3 Multilevel Set | 0x2003 | 1 | Group 7 – “Touch 3 Multilevel Set”: is assigned to touch N3. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. | 0 | |
8 | Touch 4 Basic Set | 0x2004 | 1 | Group 8 – “Touch 4 Basic Set”: is assigned to touch N4. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 0 | |
9 | Touch 4 Multilevel Set | 0x2004 | 1 | Group 9 – “Touch 4 Multilevel Set”: is assigned to touch N4. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. | 0 | |
10 | Touch 5 Basic Set | 0x2005 | 1 | Group 10 – “Touch 5 Basic Set”: is assigned to touch N5. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 0 | |
11 | Touch 5 Multilevel Set | 0x2005 | 1 | Group 11 – “Touch 5 Multilevel Set”: is assigned to touch N5. It sends MULTILEVEL SWITCH command class frame when touch N1 was held. Is used to send UP/DOWN command to the associated devices. | 0 | |
12 | LED 1 Basic Set | 0x2006 | 1 | Group 12 – “LED 1 Basic Set”: is assigned to LED N1. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 1 | |
13 | LED 2 Basic Set | 0x2007 | 1 | Group 13 – “LED 2 Basic Set”: is assigned to LED N2. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 2 | |
14 | LED 3 Basic Set | 0x2008 | 1 | Group 14 – “LED 3 Basic Set”: is assigned to LED N3. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 3 | |
15 | LED 4 Basic Set | 0x2009 | 1 | Group 14 – “LED 4 Basic Set”: is assigned to LED N4. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 4 | |
16 | LED 5 Basic Set | 0x200A | 1 | Group 16 – “LED 5 Basic Set”: is assigned to LED N5. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 5 | |
17 | Relay 1 Basic Set | 0x200B | 1 | Group 17 – “Relay 1 Basic Set”: is assigned to relay N1. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 6 | |
18 | Relay 2 Basic Set | 0x200C | 1 | Group 18 – “Relay 2 Basic Set”: is assigned to relay N2. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 7 | |
19 | Relay 3 Basic Set | 0x200D | 1 | Group 19 – “Relay 3 Basic Set”: is assigned to relay N3. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 8 | |
20 | Relay 4 Basic Set | 0x200E | 1 | Group 20 – “Relay 4 Basic Set”: is assigned to relay N4. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 9 | |
21 | Relay 5 Basic Set | 0x200F | 1 | Group 21 – “Relay 5 Basic Set”: is assigned to relay N5. Is used to send Basic Set ON (value 255) and Basic Set OFF (value 0) commands to the associated devices. | 10 |