Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Bypass Door Window Sensor Z-Wave 700 (7AA-SS-VE-C0)

Z-Wave Certification Number: ZC12-20030038


Parameter Number

Parameter Size

Parameter Name

Description

1 1 7210Range Set the range about magnetic field Range: 0-the range of parameter 0x02 is 0x00000001-0x00004B00, the range of parameter 0x03 is 0x00000001-0x00002300. 1- the range of parameter 0x02 is 0x00000001-0x0002EE00, the range of parameter 0x03 is 0x00000001-0x00015E00.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

From

 

To

Description

0   1 0-the range of parameter 0x02 is 0x00000001-0x00004B00 and the range of parameter 0x03 is 0x00000001-0x00002300. 1- the range of parameter 0x02 is 0x00000001-0x0002EE00 and the range of parameter 0x03 is 0x00000001-0x00015E00.

Parameter Number

Parameter Size

Parameter Name

Description

10 1 LowBatPrecent This parameter defines a battery level as the “low battery”. Range: 0x05-0x32

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 5 50 No No No

Value

 

Description

5   0x0A defines the low battery level. 0x05 means that device will send a low level alarm report when the battery levle is less than 5%. 0x32 means that device will send a low level alarm report when the battery levle is less than 50%.

Parameter Number

Parameter Size

Parameter Name

Description

14 1 BasicEnable Enable/Disable BASIC SET command 0 – Disable. 1 – Enable.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   parameter 14 will disable/enable the basic set command when it is triggered. the value 0 means that sensor will not send basic set command when the sensor is triggered, value 1 means that the sensor willl send basic set command when it is triggered.

Parameter Number

Parameter Size

Parameter Name

Description

15 1 BasicReverse Door Sensor reverse its value of BASIC SET when the magnet is triggered. 0 -Send BASIC SET VALUE = 0xFF/0x00 to nodes associated with group 2 when door is opened/closed. 1 –Send BASIC SET VALUE = 0/255 to nodes associated with group 2 when door is opened/closed.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

From

 

To

Description

0   1 0 -Send BASIC SET VALUE = 0xFF/0x00 to nodes associated with group 2 when door is opened/closed. 1 –Send BASIC SET VALUE = 0/255 to nodes associated with group 2 when door is opened/closed.

Parameter Number

Parameter Size

Parameter Name

Description

2 4 7210OP 7210OP Set the average magnetic field in ut Range: 0x00000001-0x00004B00 or 0x00000001-0x0002EE00

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

640 1 19200 No No No

Value

 

Description

1   the average magnetic field. 0x00000001 means that the magnetic field is 1 ut, 0x0002EE00 means that the magnetic field is 192000 ut

Parameter Number

Parameter Size

Parameter Name

Description

20 1 Bypass Enable/Disable Bypass mode 0 – Enable. 1 – Disable.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   1 parameter 20 disable/enable the bypass mode. the value 0 means that sensor will enter a bypass mode when the bypass button is pressed, value 0 means that sensor will not enter bypass mode when the bypass button is pressed

Parameter Number

Parameter Size

Parameter Name

Description

21 1 temp The interval time the Door Sensor reports the Multilevel Sensor Report to association group1 in minutes. 0x0F-0xFF

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

15 15 127 No No No

From

 

To

Description

15   127 parameter 0x21 assign the time the sensor send the temperature report to associated node in minute. For example 0x10 means that sensor will send a temperature report every 14 mins

Parameter Number

Parameter Size

Parameter Name

Description

254 1 LockConfig Enable/Disable configuration set 0 – Enable. 1 – Disable.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

From

 

To

Description

0   1 parameter 0xFE disable/enable the configuration set function. value 0 means that any configuration set will be disabled, value 1 means that configuration set will be enbale,you can change the values of the configration parameters

Parameter Number

Parameter Size

Parameter Name

Description

3 4 7210PolHyst Set the offset about magnetic field Range: 0x00000001-0x00002300 or 0x00000001-0x00015E00

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

200 1 8960 No No No

Value

 

Description

1   the offset of the magnetic field. 0x00000001 means that the magnetic field is 1 ut, 0x0002EE00 means that the magnetic field is 89600 ut